Literature DB >> 16121540

Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy.

Benjamin J Fregly1, Haseeb A Rahman, Scott A Banks.   

Abstract

Quantification of knee motion under dynamic, in vivo loaded conditions is necessary to understand how knee kinematics influence joint injury, disease, and rehabilitation. Though recent studies have measured three-dimensional knee kinematics by matching geometric bone models to single-plane fluoroscopic images, factors limiting the accuracy of this approach have not been thoroughly investigated. This study used a three-step computational approach to evaluate theoretical accuracy limitations due to the shape matching process alone. First, cortical bone models of the femur tibia/fibula, and patella were created from CT data. Next, synthetic (i.e., computer generated) fluoroscopic images were created by ray tracing the bone models in known poses. Finally, an automated matching algorithm utilizing edge detection methods was developed to align flat-shaded bone models to the synthetic images. Accuracy of the recovered pose parameters was assessed in terms of measurement bias and precision. Under these ideal conditions where other sources of error were eliminated, tibiofemoral poses were within 2 mm for sagittal plane translations and 1.5 deg for all rotations while patellofemoral poses were within 2 mm and 3 deg. However, statistically significant bias was found in most relative pose parameters. Bias disappeared and precision improved by a factor of two when the synthetic images were regenerated using flat shading (i.e., sharp bone edges) instead of ray tracing (i.e., attenuated bone edges). Analysis of absolute pose parameter errors revealed that the automated matching algorithm systematically pushed the flat-shaded bone models too far into the image plane to match the attenuated edges of the synthetic ray-traced images. These results suggest that biased edge detection is the primary factor limiting the theoretical accuracy of this single-plane shape matching procedure.

Entities:  

Mesh:

Year:  2005        PMID: 16121540      PMCID: PMC1635456          DOI: 10.1115/1.1933949

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  20 in total

1.  An interactive system for kinematic analysis of artificial joint implants.

Authors:  M Sarojak; W Hoff; R Komistek; D Dennis
Journal:  Biomed Sci Instrum       Date:  1999

2.  Correcting for deformation in skin-based marker systems.

Authors:  E J Alexander; T P Andriacchi
Journal:  J Biomech       Date:  2001-03       Impact factor: 2.712

3.  Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy.

Authors:  William A. Hoff; Richard D. Komistek; Douglas A. Dennis; Stefan M. Gabriel; Scott A. Walker
Journal:  Clin Biomech (Bristol, Avon)       Date:  1998-10       Impact factor: 2.063

4.  A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images.

Authors:  Mohamed R Mahfouz; William A Hoff; Richard D Komistek; Douglas A Dennis
Journal:  IEEE Trans Med Imaging       Date:  2003-12       Impact factor: 10.048

5.  Weight-bearing knee kinematics in subjects with two types of anterior cruciate ligament reconstructions.

Authors:  Izumi Kanisawa; Anne Z Banks; Scott A Banks; Hideshige Moriya; Akihiro Tsuchiya
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2002-12-18       Impact factor: 4.342

6.  A method to estimate in vivo dynamic articular surface interaction.

Authors:  William J Anderst; Scott Tashman
Journal:  J Biomech       Date:  2003-09       Impact factor: 2.712

7.  In vivo knee joint loading and kinematics before and after ACL transection in an animal model.

Authors:  E M Hasler; W Herzog; T R Leonard; A Stano; H Nguyen
Journal:  J Biomech       Date:  1998-03       Impact factor: 2.712

8.  Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy.

Authors:  S A Banks; W A Hodge
Journal:  IEEE Trans Biomed Eng       Date:  1996-06       Impact factor: 4.538

9.  In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties.

Authors:  S A Banks; G D Markovich; W A Hodge
Journal:  J Arthroplasty       Date:  1997-04       Impact factor: 4.757

10.  In vivo determination of knee kinematics in patients with a hamstring or patellar tendon ACL graft.

Authors:  Mohamed R Mahfouz; Steven M Traina; Richard D Komistek; Douglas A Dennis
Journal:  J Knee Surg       Date:  2003-10       Impact factor: 2.757

View more
  24 in total

1.  In Vivo Kinematics of the Anterior Cruciate Ligament Deficient Knee During Wide-Based Squat Using a 2D/3D Registration Technique.

Authors:  Takeshi Miyaji; Kazuyoshi Gamada; Kenichi Kidera; Futoshi Ikuta; Kei Yoneta; Hiroyuki Shindo; Makoto Osaki; Akihiko Yonekura
Journal:  J Sports Sci Med       Date:  2012-12-01       Impact factor: 2.988

2.  Evaluation of automated statistical shape model based knee kinematics from biplane fluoroscopy.

Authors:  Nora Baka; Bart L Kaptein; J Erik Giphart; Marius Staring; Marleen de Bruijne; Boudewijn P F Lelieveldt; Edward Valstar
Journal:  J Biomech       Date:  2013-10-09       Impact factor: 2.712

3.  In vitro quantification of the performance of model-based mono-planar and bi-planar fluoroscopy for 3D joint kinematics estimation.

Authors:  Luca Tersi; Arnaud Barré; Silvia Fantozzi; Rita Stagni
Journal:  Med Biol Eng Comput       Date:  2012-11-11       Impact factor: 2.602

4.  A method for measuring three-dimensional mandibular kinematics in vivo using single-plane fluoroscopy.

Authors:  C-C Chen; C-C Lin; Y-J Chen; S-W Hong; T-W Lu
Journal:  Dentomaxillofac Radiol       Date:  2012-07-27       Impact factor: 2.419

Review 5.  MRI of weight bearing and movement.

Authors:  L M Shapiro; G E Gold
Journal:  Osteoarthritis Cartilage       Date:  2011-11-17       Impact factor: 6.576

6.  Assessing the accuracy and precision of musculoskeletal motion tracking using cine-PC MRI on a 3.0T platform.

Authors:  Abrahm J Behnam; Daniel A Herzka; Frances T Sheehan
Journal:  J Biomech       Date:  2010-09-21       Impact factor: 2.712

7.  Statistical shape modeling predicts patellar bone geometry to enable stereo-radiographic kinematic tracking.

Authors:  Lowell M Smoger; Kevin B Shelburne; Adam J Cyr; Paul J Rullkoetter; Peter J Laz
Journal:  J Biomech       Date:  2017-05-17       Impact factor: 2.712

8.  High-speed X-ray video demonstrates significant skin movement errors with standard optical kinematics during rat locomotion.

Authors:  Jay M Bauman; Young-Hui Chang
Journal:  J Neurosci Methods       Date:  2009-11-10       Impact factor: 2.390

9.  Feasibility of using real-time MRI to measure joint kinematics in 1.5T and open-bore 0.5T systems.

Authors:  Christine E Draper; Juan M Santos; Lampros C Kourtis; Thor F Besier; Michael Fredericson; Gary S Beaupre; Garry E Gold; Scott L Delp
Journal:  J Magn Reson Imaging       Date:  2008-07       Impact factor: 4.813

10.  Screw-Home Movement of the Tibiofemoral Joint during Normal Gait: Three-Dimensional Analysis.

Authors:  Ha Yong Kim; Kap Jung Kim; Dae Suk Yang; Sang Wook Jeung; Han Gyeol Choi; Won Sik Choy
Journal:  Clin Orthop Surg       Date:  2015-08-13
View more