Literature DB >> 14634743

[Navigated osteosynthesis of the proximal femur. An experimental study].

T Hüfner1, M Kfuri, D Kendoff, M Richter, J Geerling, C Krettek.   

Abstract

Screw position in femoral head has been considered the most important predictive factor for mechanical failure in pertrochanteric osteosynthesis, and correct positioning is assisted by fluoroscopic control. Although fluoroscopy leads to precise and reproducible results, it is associated with scattered radiation to the patient and surgical staff. Computer-assisted surgery (CAS) may be an alternative in means of achieving precise screw insertion with a low radiation dose. We designed a laboratory study in which artificial proximal femora were submitted to insertions of a dynamic hip screw (DHS) and an anti-rotational screw (ARS). Three set-ups were tested: (1) conventional implantation with two simultaneous C-arms using a guide wire; (2) drilling and implantation controlled by CAS solely with a 3.2-mm drill bit, then insertion of a guide wire and drilling for the dynamic hip screw; (3) after navigated drilling (3.2 mm) a fluoroscopic control was performed. Five variables were used comparing methods and surgeons: operation time, radiation time, tip-apex distance (TAD), and the insertion neck-shaft angles of DHS and ARS. Considering TAD as a precision parameter, CAS led to screw insertion as accurate as with fluoroscopic control, with a reduction of radiation time up to 93%.

Entities:  

Mesh:

Year:  2003        PMID: 14634743     DOI: 10.1007/s00113-003-0688-4

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  14 in total

1.  [Precision in standardized Iso-C-Arm based navigated boring of the proximal femur].

Authors:  M Arand; M Schempf; L Kinzl; T Fleiter; D Pless; F Gebhard
Journal:  Unfallchirurg       Date:  2001-12       Impact factor: 1.000

2.  [Accuracy of fluoroscopically navigated drilling procedures at the hip].

Authors:  J A K Ohnsorge; E Schkommodau; D C Wirtz; J E Wildberger; A Prescher; C H Siebert
Journal:  Z Orthop Ihre Grenzgeb       Date:  2003 Jan-Feb

Review 3.  Computer-assisted orthopaedic surgery: do we need CAOS?

Authors:  J M Sikorski; S Chauhan
Journal:  J Bone Joint Surg Br       Date:  2003-04

4.  Hip fractures in Finland between 1970 and 1997 and predictions for the future.

Authors:  P Kannus; S Niemi; J Parkkari; M Palvanen; I Vuori; M Järvinen
Journal:  Lancet       Date:  1999-03-06       Impact factor: 79.321

5.  Predictors of functional recovery after hip fracture in the elderly.

Authors:  K J Koval; M L Skovron; G B Aharonoff; J D Zuckerman
Journal:  Clin Orthop Relat Res       Date:  1998-03       Impact factor: 4.176

6.  Exposure of the orthopaedic surgeon to radiation.

Authors:  R Sanders; K J Koval; T DiPasquale; G Schmelling; S Stenzler; E Ross
Journal:  J Bone Joint Surg Am       Date:  1993-03       Impact factor: 5.284

7.  Predictors of outcome following hip fracture. Admission time predicts length of stay and in-hospital mortality.

Authors:  John E Clague; Elaine Craddock; Glynn Andrew; Michael A Horan; Neil Pendleton
Journal:  Injury       Date:  2002-01       Impact factor: 2.586

8.  The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip.

Authors:  K P Kosygan; R Mohan; R J Newman
Journal:  J Bone Joint Surg Br       Date:  2002-01

9.  The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip.

Authors:  M R Baumgaertner; S L Curtin; D M Lindskog; J M Keggi
Journal:  J Bone Joint Surg Am       Date:  1995-07       Impact factor: 5.284

10.  Ionising radiation during internal fixation of extracapsular neck of femur fractures.

Authors:  P V Giannoudis; J McGuigan; D L Shaw
Journal:  Injury       Date:  1998-07       Impact factor: 2.586

View more
  4 in total

Review 1.  [Precision in orthopaedic computer navigation].

Authors:  T Hüfner; D Kendoff; M Citak; J Geerling; C Krettek
Journal:  Orthopade       Date:  2006-10       Impact factor: 1.087

2.  [Evaluation of a 2D fluoroscopy-based navigation system for insertion of femoral neck screws. An experimental study].

Authors:  M C Müller; P Belei; M de la Fuente; M Strake; K Kabir; O Weber; C Burger; K Radermacher; D C Wirtz
Journal:  Unfallchirurg       Date:  2012-09       Impact factor: 1.000

3.  [A new parallel drill guide for navigating femoral neck screw placement. Development and evaluation].

Authors:  D Kendoff; T Hüfner; M Citak; C Maier; F Wesemeier; A Pearle; C Krettek
Journal:  Unfallchirurg       Date:  2006-10       Impact factor: 1.000

4.  Computer-assisted Femur Fracture Reduction.

Authors:  Johannes Frank; Bernd Gritzbach; Christian Winter; Bernd Maier; Ingo Marzi
Journal:  Eur J Trauma Emerg Surg       Date:  2010-03-08       Impact factor: 3.693

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.