Evaluation of right and left ventricular volume and ejection fraction using a mathematical cardiac torso phantom.

P H Pretorius1, W Xia, M A King, B M Tsui, T S Pan, B J Villegas.   

Abstract

UNLABELLED: The availability of gated SPECT has increased the interest in the determination of volume and ejection fraction of the left ventricle (LV) for clinical diagnosis. However, the same indices for the right ventricle (RV) have been neglected. The objective of this investigation was to use a mathematical model of the anatomical distribution of activity in gated blood-pool imaging to evaluate the accuracy of two ventricular volume and ejection fraction determination methods. In this investigation, measurements from the RV were emphasized.
METHODS: The mathematical cardiac torso phantom, developed to study LV myocardium perfusion, was modified to simulate the radioactivity distribution of a 99mTc-gated blood-pool study. Twenty mathematical cardiac torso phantom models of the normal heart with different LV volumes (122.3 +/- 11.0 ml), RV volumes (174.6 +/- 22.3 ml) and stroke volumes (75.7 +/- 3.3 ml) were randomly generated to simulate variations among patients. An analytical three-dimensional projector with attenuation and system response was used to generate SPECT projection sets, after which noise was added. The projections were simulated for 128 equidistant views in a 360 degrees rotation mode.
RESULTS: The radius of rotation was varied between 24 and 28 cm to mimic such variation in patient acquisitions. The 180 degrees and 360 degrees projection sets were reconstructed using the filtered backprojection reconstruction algorithm with Butter-worth filtering. Comparison was made with and without application of the iterative Chang attenuation correction algorithm. Volumes were calculated using a modified threshold and edge detection method (hybrid threshold), as well as a count-based method. A simple background correction procedure was used with both methods.
CONCLUSION: Results indicate that cardiac functional parameters can be measured with reasonable accuracy using both methods. However, the count-based method had a larger bias than the hybrid threshold method when RV parameters were determined for 180 degrees reconstruction without attenuation correction. This bias improved after attenuation correction. The count-based method also tended to overestimate the end systolic volume slightly. An improved background correction could possibly alleviate this bias.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9379187

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  14 in total

1.  Analytical propagation of errors in dynamic SPECT: estimators, degrading factors, bias and noise.

Authors:  D J Kadrmas; E V DiBella; R H Huesman; G T Gullberg
Journal:  Phys Med Biol       Date:  1999-08       Impact factor: 3.609

2.  4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior.

Authors:  D J Kadrmas; G T Gullberg
Journal:  Phys Med Biol       Date:  2001-05       Impact factor: 3.609

3.  Myocardial gated SPECT phantom.

Authors:  Boguslaw Stefaniak; Witold Cholewinski; Anna Tarkowska
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-05-19       Impact factor: 9.236

Review 4.  Anniversary paper: History and status of CAD and quantitative image analysis: the role of Medical Physics and AAPM.

Authors:  Maryellen L Giger; Heang-Ping Chan; John Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

5.  An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package in simulated gated SPECT images.

Authors:  A D Achtert; M A King; S T Dahlberg; P H Pretorius; K J LaCroix; B M Tsui
Journal:  J Nucl Cardiol       Date:  1998 Mar-Apr       Impact factor: 5.952

6.  FAST ANALYTICAL RECONSTRUCTION OF GATED CARDIAC SPECT WITH NON-UNIFORM ATTENUATION COMPENSATION.

Authors:  Yi Fan; Hongbing Lu; Chongyang Hao; Zhengrong Liang; Zhiming Zhou
Journal:  Int J Image Graph       Date:  2007-01

7.  Influence of CT-based attenuation correction in assessment of left and right ventricular functions with count-based gated blood-pool SPECT.

Authors:  Louis Sibille; Fayçal Ben Bouallegue; Aurélie Bourdon; Denis Mariano-Goulart
Journal:  J Nucl Cardiol       Date:  2011-06-07       Impact factor: 5.952

8.  4D reconstruction for low-dose cardiac gated SPECT.

Authors:  Mingwu Jin; Xiaofeng Niu; Wenyuan Qi; Yongyi Yang; Joyoni Dey; Michael A King; Seth Dahlberg; Miles N Wernick
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

Review 9.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

10.  Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1999-07       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.