Abstract

Conventionally, the inverse problem of gated cardiac SPECT is solved by reconstructing the images frame-by-frame, ignoring the inter-frame correlation along the time dimension. To compensate for the non-uniform attenuation for quantitative cardiac imaging, iterative image reconstruction has been a choice which could utilize an a priori constraint on the inter-frame correlation for a penalized maximum likelihood (ML) solution. However, iterative image reconstruction in the 4D space involves intensive computations. In this paper, an efficient method for 4D gated SPECT reconstruction is developed based on Karhune-Loève (KL) transform and Novikov's inverse formula. The temporal KL transform is first applied on the data sequence to de-correlate the inter-frame correlation and then the 3D principal components in the KL domain are reconstructed frame-by-frame using Novikov's inverse formula with non-uniform attenuation compensation. Finally an inverse KL transform is performed to obtain quantitatively-reconstructed 4D images in the original space. With the proposed method, 4D reconstruction can be achieved at a reasonable computational cost. The results from computer simulations are very encouraging as compared to conventional frame-by-frame filtered back-projection and iterative ordered-subsets ML reconstructions. By discarding high-order KL components for further noise reduction, the computation time could be further reduced.

Entities:  

Year:  2007        PMID: 18509522      PMCID: PMC2396956          DOI: 10.1142/S0219467807002556

Source DB:  PubMed          Journal:  Int J Image Graph


  14 in total

Review 1.  Fast spatio-temporal image reconstruction for dynamic PET.

Authors:  M N Wernick; E J Infusino; M Milosević
Journal:  IEEE Trans Med Imaging       Date:  1999-03       Impact factor: 10.048

2.  Improved image quality and computation reduction in 4-D reconstruction of cardiac-gated SPECT images.

Authors:  M V Narayanan; M A King; M N Wernick; C L Byrne; E J Soares; P H Pretorius
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

3.  Optimum compensation method and filter cutoff frequency in myocardial SPECT: a human observer study.

Authors:  Sharlini Sankaran; Eric C Frey; Karen L Gilland; Benjamin M W Tsui
Journal:  J Nucl Med       Date:  2002-03       Impact factor: 10.057

4.  An FDK-like cone-beam SPECT reconstruction algorithm for non-uniform attenuated projections acquired using a circular trajectory.

Authors:  Q Huang; G L Zeng; J You; G T Gullberg
Journal:  Phys Med Biol       Date:  2005-05-05       Impact factor: 3.609

5.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

6.  Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT.

Authors:  D S Lalush; B M Tsui
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

7.  Image reconstruction for dynamic PET based on low-order approximation and restoration of the sinogram.

Authors:  C M Kao; J T Yap; J Mukherjee; M N Wernick
Journal:  IEEE Trans Med Imaging       Date:  1997-12       Impact factor: 10.048

8.  Evaluation of right and left ventricular volume and ejection fraction using a mathematical cardiac torso phantom.

Authors:  P H Pretorius; W Xia; M A King; B M Tsui; T S Pan; B J Villegas
Journal:  J Nucl Med       Date:  1997-10       Impact factor: 10.057

9.  The use of principal components in the quantitative analysis of gamma camera dynamic studies.

Authors:  D C Barber
Journal:  Phys Med Biol       Date:  1980-03       Impact factor: 3.609

10.  Evaluation of an efficient compensation method for quantitative fan-beam brain SPECT reconstruction.

Authors:  Tianfang Li; Junhai Wen; Guoping Han; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2005-02       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.