Literature DB >> 29958198

Single-Shot Coronary Quiescent-Interval Slice-Selective Magnetic Resonance Angiography Using Compressed Sensing: A Feasibility Study in Patients With Congenital Heart Disease.

Daming Shen, Robert R Edelman, Joshua D Robinson1, Hassan Haji-Valizadeh, Marci Messina2, Shivraman Giri3, Ioannis Koktzoglou, Cynthia K Rigsby, Daniel Kim.   

Abstract

OBJECTIVE: The aim of this study was to determine whether it is feasible to visualize the coronary origins in patients with congenital heart disease (CHD) using single-shot coronary quiescent-interval slice-selective (QISS) magnetic resonance angiography (MRA) with compressed sensing (CS).
METHODS: This retrospective study leveraged a parent study, which aimed to compare breath-hold, 2.1-fold accelerated, 2-shot coronary QISS MRA and clinical standard contrast-enhanced (CE) MRA in 14 patients with CHD (mean age, 17.0 ± 8.6 years, 6 females and 8 males). We evaluated the feasibility of single-shot coronary QISS MRA by retrospectively undersampling the 2-shot data set by an additional factor of 2, performing CS reconstruction, and comparing the retrospectively derived single-shot QISS MRA to 2-shot coronary QISS MRA and clinical standard CE MRA. For quantitative analysis, structural similarity index and normalized root mean square error were calculated. For qualitative analysis, 2 experienced readers scored the conspicuity of coronary origins on a 5-point Likert scale (1 = nondiagnostic, 2 = poor, 3 = clinically acceptable, 4 = good, 5 = excellent).
RESULTS: Compared with 2-shot QISS, single-shot QISS produced normalized root mean square error of 5.8% ± 0.8% and structural similarity index of 95.4% ± 1.6%, suggesting high data fidelity by CS reconstruction. Compared with the mean conspicuity scores for clinical CE MRA (4.2 ± 0.5 and 4.1 ± 0.6 for right and left coronary origins, respectively), the mean conspicuity scores were not significantly different (P > 0.3) for 2-shot QISS (4.4 ± 0.9 and 4.2 ± 1.1, respectively) and single-shot QISS with CS (4.3 ± 1.1 and 3.8 ± 1.3, respectively) and deemed clinically acceptable to good (scores ≥3.0).
CONCLUSIONS: This study shows that it is feasible to visualize the coronary origins in patients with CHD with clinically acceptable to good image quality using single-shot coronary QISS MRA with CS.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29958198      PMCID: PMC6138547          DOI: 10.1097/RCT.0000000000000760

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  37 in total

1.  Non-contrast-enhanced MR angiography of the thoracic aorta using cardiac and navigator-gated magnetization-prepared three-dimensional steady-state free precession.

Authors:  Yasuo Amano; Katsuya Takahama; Shinichiro Kumita
Journal:  J Magn Reson Imaging       Date:  2008-03       Impact factor: 4.813

2.  Unenhanced MR angiography of the thoracic aorta: initial clinical evaluation.

Authors:  Christopher J François; David Tuite; Vibhas Deshpande; Renate Jerecic; Peter Weale; James C Carr
Journal:  AJR Am J Roentgenol       Date:  2008-04       Impact factor: 3.959

Review 3.  Nonenhanced MR angiography.

Authors:  Mitsue Miyazaki; Vivian S Lee
Journal:  Radiology       Date:  2008-07       Impact factor: 11.105

4.  Whole-heart coronary MR angiography under a single breath-hold: a comparative study with respiratory-gated acquisition using a multi-element phased-array coil.

Authors:  T Okada; S Kanao; S Kuhara; A Ninomiya; K Fujimoto; A Kido; K Togashi
Journal:  Clin Radiol       Date:  2011-11       Impact factor: 2.350

5.  Implementation and evaluation of frequency offset corrected inversion (FOCI) pulses on a clinical MR system.

Authors:  G S Payne; M O Leach
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

Review 6.  Radiation risks from cardiovascular imaging tests.

Authors:  Felix G Meinel; John W Nance; Brett S Harris; Carlo N De Cecco; Philip Costello; U Joseph Schoepf
Journal:  Circulation       Date:  2014-07-29       Impact factor: 29.690

7.  Non-cartesian MRI reconstruction with automatic regularization Via Monte-Carlo SURE.

Authors:  Sathish Ramani; Daniel S Weller; Jon-Fredrik Nielsen; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2013-04-12       Impact factor: 10.048

Review 8.  Toxicity of MRI and CT contrast agents.

Authors:  Kendra M Hasebroock; Natalie J Serkova
Journal:  Expert Opin Drug Metab Toxicol       Date:  2009-04       Impact factor: 4.481

9.  Progressive increase of T1 signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted MR images in the pediatric brain exposed to multiple doses of gadolinium contrast.

Authors:  Donna R Roberts; Kenton R Holden
Journal:  Brain Dev       Date:  2015-09-04       Impact factor: 1.961

10.  A fast, noniterative approach for accelerated high-temporal resolution cine-CMR using dynamically interleaved streak removal in the power-spectral encoded domain with low-pass filtering (DISPEL) and modulo-prime spokes (MoPS).

Authors:  Keigo Kawaji; Mita B Patel; Charles G Cantrell; Akiko Tanaka; Marco Marino; Satoshi Tamura; Hui Wang; Yi Wang; Timothy J Carroll; Takeyoshi Ota; Amit R Patel
Journal:  Med Phys       Date:  2017-05-23       Impact factor: 4.071

View more
  1 in total

1.  Coronary Artery Magnetic Resonance Angiography Combined with Computed Tomography Angiography in Diagnosis of Coronary Heart Disease by Reconstruction Algorithm.

Authors:  Yun Ling; Jiapei Qiu; Jun Liu
Journal:  Contrast Media Mol Imaging       Date:  2022-03-23       Impact factor: 3.009

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.