Literature DB >> 9358450

T2 accuracy on a whole-body imager.

W D Foltz1, J A Stainsby, G A Wright.   

Abstract

MR oximetry requires a T2 measurement that is accurate within 5% in vivo. Simple methods are susceptible to signal loss and tend to underestimate T2. Current methods utilize RF pulses or RF cycling patterns that prevent signal loss at each data acquisition. However, using these methods with imperfect pulses, T2 tends to be overestimated due to temporary storage of the magnetization along the longitudinal axis where it decays more slowly with a time constant T1 > T2. To reduce the T1 dependence while preventing signal loss, we utilize simple 90x180y90x composite pulses and good RF cycling patterns. These trains are critical for T2 accuracy over typical ranges of RF and static field inhomogeneities and refocusing intervals. T1 signal decay during each 90x180y90x pulse must be accounted for to yield accuracy within 5% when the pulse-width is 10% or more of the refocusing interval. A simple correction scheme compensates for this T1-related error effectively.

Mesh:

Substances:

Year:  1997        PMID: 9358450     DOI: 10.1002/mrm.1910380512

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  A novel technique to enable experimental validation of deformable dose accumulation.

Authors:  Carolyn J Niu; Warren D Foltz; Michael Velec; Joanne L Moseley; Adil Al-Mayah; Kristy K Brock
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  T2 -prepared balanced steady-state free precession (bSSFP) for quantifying whole-blood oxygen saturation at 1.5T.

Authors:  Ana E Rodríguez-Soto; Osheiza Abdulmalik; Michael C Langham; Nadav Schwartz; Hyunyeol Lee; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2017-07-17       Impact factor: 4.668

3.  Fast radio-frequency enforced steady state (FRESS) spin echo MRI for quantitative T2 mapping: minimizing the apparent repetition time (TR) dependence for fast T2 measurement.

Authors:  Jerry S Cheung; Enfeng Wang; XiaoAn Zhang; Emiri Mandeville; Eng H Lo; A Gregory Sorensen; Phillip Zhe Sun
Journal:  NMR Biomed       Date:  2011-07-14       Impact factor: 4.044

4.  Propagation of error from parameter constraints in quantitative MRI: Example application of multiple spin echo T2 mapping.

Authors:  Christopher L Lankford; Mark D Does
Journal:  Magn Reson Med       Date:  2017-04-20       Impact factor: 4.668

5.  Quantification of whole-brain oxygenation extraction fraction and cerebral metabolic rate of oxygen consumption in adults with sickle cell anemia using individual T2 -based oxygenation calibrations.

Authors:  Wenbo Li; Xiang Xu; Peiying Liu; John J Strouse; James F Casella; Hanzhang Lu; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2019-09-04       Impact factor: 4.668

6.  Quantitative theory for the transverse relaxation time of blood water.

Authors:  Wenbo Li; Peter C M van Zijl
Journal:  NMR Biomed       Date:  2020-02-05       Impact factor: 4.044

7.  Cross-vendor harmonization of T2 -relaxation-under-spin-tagging (TRUST) MRI for the assessment of cerebral venous oxygenation.

Authors:  Dengrong Jiang; Peiying Liu; Yang Li; Deng Mao; Cuimei Xu; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2018-01-25       Impact factor: 4.668

8.  Determination of whole-brain oxygen extraction fractions by fast measurement of blood T(2) in the jugular vein.

Authors:  Qin Qin; Ksenija Grgac; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

9.  In vivo whole-blood T2 versus HbO2 calibration by modulating blood oxygenation level in the femoral vein through intermittent cuff occlusion.

Authors:  Michael C Langham; Ana E Rodríguez-Soto; Nadav Schwartz; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2017-09-03       Impact factor: 4.668

10.  Magnetic resonance measurement of muscle T2, fat-corrected T2 and fat fraction in the assessment of idiopathic inflammatory myopathies.

Authors:  Lawrence Yao; Adrienne L Yip; Joseph A Shrader; Sepehr Mesdaghinia; Rita Volochayev; Anna V Jansen; Frederick W Miller; Lisa G Rider
Journal:  Rheumatology (Oxford)       Date:  2015-09-27       Impact factor: 7.580

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.