Literature DB >> 9356622

Clip placement after stereotactic vacuum-assisted breast biopsy.

L Liberman1, D D Dershaw, E A Morris, A F Abramson, C M Thornton, P P Rosen.   

Abstract

PURPOSE: To assess accuracy and usefulness of placement of a localizing clip after stereotactic, vacuum-assisted breast biopsy.
MATERIALS AND METHODS: Retrospective review was performed of 57 lesions that underwent placement of a localizing clip after stereotactic vacuum-assisted biopsy with an 11-gauge (n = 42) or 14-gauge (n = 15) probe. The clip was placed when images obtained after stereotactic biopsy suggested that the lesion seen at mammography was removed. Coordinates of the clip on stereotactic images obtained after placement were compared with lesion coordinates determined before biopsy. Surgery was performed in 25 cases. Mammographic and histopathologic findings were reviewed.
RESULTS: The distance from clip to lesion site was less than 1 cm in 40 (95%) of 42 lesions that underwent clip placement with the 11-gauge probe versus 11 (73%) of 15 lesions that underwent clip placement after 14-gauge biopsy (P < .04). The biopsy site was identified in the surgical specimen in 19 (100%) lesions with clips after 11-gauge biopsy and five (83%) of six lesions with clips after 14-gauge biopsy. No complications occurred.
CONCLUSION: A localizing clip can be placed in proximity to the stereotactic biopsy site through an 11-gauge probe. Clip placement can enable accurate localization for surgical excision.

Entities:  

Mesh:

Year:  1997        PMID: 9356622     DOI: 10.1148/radiology.205.2.9356622

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  19 in total

Review 1.  Stereotactic and ultrasound-guided breast biopsy.

Authors:  T H Helbich; W Matzek; M H Fuchsjäger
Journal:  Eur Radiol       Date:  2003-11-13       Impact factor: 5.315

2.  [O-twist marker for post-interventional marking in imaging of suspected breast lesions].

Authors:  H Sittek; N Heske; M Kessler; S Britsch; C Vick; M Untch; M Reiser
Journal:  Radiologe       Date:  2005-03       Impact factor: 0.635

3.  [Clip marker placement following MR-guided vacuum biopsy of the breast].

Authors:  C Perlet; H Sittek; M Reiser; S H Heywang-Köbrunner
Journal:  Radiologe       Date:  2005-03       Impact factor: 0.635

4.  Can galactography-guided stereotactic, 11-gauge, vacuum-assisted breast biopsy of intraductal lesions serve as an alternative to surgical biopsy?

Authors:  Caecilia S Reiner; Thomas H Helbich; Margaretha Rudas; Lothar Ponhold; Christopher C Riedl; Nina Kropf; Michael H Fuchsjäger
Journal:  Eur Radiol       Date:  2009-12       Impact factor: 5.315

5.  Modulation of photoacoustic signal generation from metallic surfaces.

Authors:  Trevor Mitcham; Kimberly Homan; Wolfgang Frey; Yun-Sheng Chen; Stanislav Emelianov; John Hazle; Richard Bouchard
Journal:  J Biomed Opt       Date:  2013-05       Impact factor: 3.170

6.  A prospective comparative study to evaluate the displacement of four commercially available breast biopsy markers.

Authors:  David M Pinkney; Mirek Mychajlowycz; Biren A Shah
Journal:  Br J Radiol       Date:  2016-07-04       Impact factor: 3.039

7.  Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips.

Authors:  R Schulz-Wendtland; P Dankerl; G Dilbat; M Bani; P A Fasching; K Heusinger; M P Lux; C R Loehberg; S M Jud; C Rauh; C M Bayer; M W Beckmann; D L Wachter; M Uder; M Meier-Meitinger; B Brehm
Journal:  Geburtshilfe Frauenheilkd       Date:  2015-01       Impact factor: 2.915

8.  Evaluation of a Marker Clip System in Sonographically Guided Core Needle Biopsy for Breast Cancer Localization Before and After Neoadjuvant Chemotherapy.

Authors:  R Schulz-Wendtland; P Dankerl; M R Bani; P A Fasching; K Heusinger; M P Lux; S M Jud; C Rauh; C M Bayer; M G Schrauder; M W Beckmann; M Uder; B Brehm; C R Loehberg
Journal:  Geburtshilfe Frauenheilkd       Date:  2017-02       Impact factor: 2.915

9.  Evaluation of Newly Adapted Clip Marker System in Ultrasound-Guided Core Needle Biopsy for Suspicion of Breast Cancer.

Authors:  R Schulz-Wendtland; P Dankerl; G Dilbat; M Bani; P A Fasching; K Heusinger; M P Lux; C R Loehberg; S M Jud; C Rauh; C M Bayer; M W Beckmann; M Uder; M Meier-Meitinger; B Brehm
Journal:  Geburtshilfe Frauenheilkd       Date:  2013-11       Impact factor: 2.915

10.  The value of ultrasound-guided tattooing localization of nonpalpable breast lesions.

Authors:  Kyungran Ko; Boo Kyung Han; Kyung Mi Jang; Yeon Hyeon Choe; Jung Hee Shin; Jung Hyun Yang; Suk Jin Nam
Journal:  Korean J Radiol       Date:  2007 Jul-Aug       Impact factor: 3.500

View more