Literature DB >> 15726309

[Clip marker placement following MR-guided vacuum biopsy of the breast].

C Perlet1, H Sittek, M Reiser, S H Heywang-Köbrunner.   

Abstract

PURPOSE: The purpose of our study was to determine the placement accuracy, usefulness as a guide for wire localization, and long-term stability of tissue marker clips following MR-guided vacuum-assisted biopsy (VB) of breast lesions.
METHODS: During a 2-year period, MR-guided VB with an 11-gauge device was performed in 79 lesions. In 26 lesions a marker clip was placed at the biopsy site.
RESULTS: In 18 cases, the clip was shown to be closely adjacent to the lesion on post-interventional MR images. In seven cases in which minor bleeding occurred, the clip dislocated (< or =15 mm) in the direction of the needle pathway. In one case dislocation in the dorsal direction (< or =5 mm) was observed. In eight cases with a malignant or borderline histology according to the VB, the marker clips served as targets for mammographically guided wire localization. In all of those patients, histology results derived from open surgery confirmed those of VB. Eighteen patients with benign findings according to the VB were followed up 6 months later. Among these cases we found a significant displacement of the marker clip in one case (3 cm). The clip generally caused a round artifact (diameter of 9+/-2 mm). In two cases it was not possible to determine whether the lesion had been removed completely or was just behind the artifact caused by the clip.
CONCLUSION: Based on our results, clip marker placement following MR-guided vacuum biopsy should be called into question due to the possibility of masking the lesion by a metallic artifact and because of possible dislocation.

Entities:  

Mesh:

Year:  2005        PMID: 15726309     DOI: 10.1007/s00117-005-1173-6

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  19 in total

1.  [Minimally invasive surgical procedures of the breast: comparison of different biopsy systems in a breast parenchymal model].

Authors:  H Sittek; P Schneider; C Perlet; C Baudrexel; M Reiser
Journal:  Radiologe       Date:  2002-01       Impact factor: 0.635

2.  The UK national study of magnetic resonance imaging as a method of screening for breast cancer (MARIBS).

Authors:  M O Leach; R A Eeles; L W Turnbull; A K Dixon; J Brown; R J C Hoff; A Coulthard; J M Dixon; D F Easton; D G R Evans; F J Gilbert; J Hawnaur; C Hayes; P Kessar; S Lakhani; G Liney; S M Moss; A P Padhani; L J Pointon; M Sydenham; L G Walker; R M L Warren; N E Haites; P Morrison; T Cole; Z Rayter; A Donaldson; M Shere; J Rankin; D Goudie; C M Steel; R Davidson; C Chu; I Ellis; J Mackay; S V Hodgson; T Homfray; F Douglas; O W Quarrell; D M Eccles; F G Gilbert; G Crothers; C P Walker; A Jones; N Slack; P Britton; D G Sheppard; J Walsh; G Whitehouse; W Teh; S Rankin; C Boggis; J Potterton; L McLean; P A L Gordon; C Rubin
Journal:  J Exp Clin Cancer Res       Date:  2002-09

3.  Marker clip placement following directional, vacuum-assisted breast biopsy.

Authors:  H E Reynolds
Journal:  Am Surg       Date:  1999-01       Impact factor: 0.688

4.  Tissue marking clip for stereotactic breast biopsy: initial placement accuracy, long-term stability, and usefulness as a guide for wire localization.

Authors:  F Burbank; N Forcier
Journal:  Radiology       Date:  1997-11       Impact factor: 11.105

5.  [Value of contrast medium magnetic resonance tomography of the breast in breast reconstruction with implant].

Authors:  A Heinig; S H Heywang-Köbrunner; P Viehweg; D Lampe; J Buchmann; R P Spielmann
Journal:  Radiologe       Date:  1997-09       Impact factor: 0.635

6.  Routine screening for local recurrence following breast-conserving therapy for cancer with dynamic contrast-enhanced magnetic resonance imaging of the breast.

Authors:  P J Drew; M J Kerin; L W Turnbull; M Imrie; P J Carleton; J N Fox; J R Monson
Journal:  Ann Surg Oncol       Date:  1998 Apr-May       Impact factor: 5.344

7.  Breast carcinoma: effect of preoperative contrast-enhanced MR imaging on the therapeutic approach.

Authors:  U Fischer; L Kopka; E Grabbe
Journal:  Radiology       Date:  1999-12       Impact factor: 11.105

8.  Prototype breast coil for MR-guided needle localization.

Authors:  S H Heywang-Köbrunner; A T Huynh; P Viehweg; W Hanke; H Requardt; I Paprosch
Journal:  J Comput Assist Tomogr       Date:  1994 Nov-Dec       Impact factor: 1.826

9.  Vacuum-assisted stereotactic breast biopsy: histologic underestimation of malignant lesions.

Authors:  W E Burak; K E Owens; M B Tighe; L Kemp; S A Dinges; C L Hitchcock; J Olsen
Journal:  Arch Surg       Date:  2000-06

Review 10.  Recognizing pitfalls in early and late migration of clip markers after imaging-guided directional vacuum-assisted biopsy.

Authors:  Lisa E Esserman; Marco A Cura; Darlene DaCosta
Journal:  Radiographics       Date:  2004 Jan-Feb       Impact factor: 5.333

View more
  2 in total

1.  Application of ultrasound-guided placement of markers for locating axillary lymph nodes of breast cancer.

Authors:  Xiaohui Ji; Mengying Wei; Liuyuan Wang; Juanjuan Li; Dongxia Gao; Cuizhi Geng
Journal:  Gland Surg       Date:  2021-11

Review 2.  [Interventional MRI of the breast. Indications, technique, results and perspectives].

Authors:  K Hellerhoff; T Schlossbauer; P Herzog; M Reiser
Journal:  Radiologe       Date:  2008-04       Impact factor: 0.635

  2 in total