Spectral analysis of AC and DC components of the pulse photoplethysmograph at rest and during induction of anaesthesia.

P D Larsen1, M Harty, M Thiruchelvam, D C Galletly.   

Abstract

We examined spectral components of beat to beat variability in AC and DC signals of the reflectance photoplethysmograph at finger and earlobe sites in 20 resting volunteers and 20 patients during propofol, alfentanil, isoflurane, nitrous oxide anaesthesia. We observed that at rest, the majority of spectral power at both sites and in both signals was in the low 'thermoregulatory' frequency band (0.01-0.08 Hz). These fluctuations were greater in the finger than in the earlobe and in the AC signal compared to the DC. With anaesthesia, low as well as mid (0.08-0.15 Hz) frequency variability decreased at both sites and in both signals whereas high frequency 'ventilatory' power (0.15-0.45 Hz) was maintained. During anaesthesia we found no significant differences between the spectral components of the AC or DC signals or between the finger and the earlobe sites. At all frequencies, the fluctuations in the AC and DC signals were out of phase with each other.

Entities:  

Mesh:

Year:  1997        PMID: 9336733     DOI: 10.1007/bf03356582

Source DB:  PubMed          Journal:  Int J Clin Monit Comput        ISSN: 0167-9945


  8 in total

1.  Respiratory variations in the reflection mode photoplethysmographic signal. Relationships to peripheral venous pressure.

Authors:  L Nilsson; A Johansson; S Kalman
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

2.  Non-invasive continuous estimation of blood flow changes in human patellar bone.

Authors:  Jan Näslund; Jonas Pettersson; Thomas Lundeberg; Dag Linnarsson; Lars-Göran Lindberg
Journal:  Med Biol Eng Comput       Date:  2006-06-03       Impact factor: 2.602

3.  Spectral analysis of finger photoplethysmographic waveform variability in a model of mild to moderate haemorrhage.

Authors:  Paul M Middleton; Gregory S H Chan; Emma O'Lone; Elizabeth Steel; Rebecca Carroll; Branko G Celler; Nigel H Lovell
Journal:  J Clin Monit Comput       Date:  2008-10-11       Impact factor: 2.502

4.  Fingertip photoplethysmographic waveform variability and systemic vascular resistance in intensive care unit patients.

Authors:  Paul M Middleton; Gregory S H Chan; Elizabeth Steel; Philip Malouf; Christopher Critoph; Gordon Flynn; Emma O'Lone; Branko G Celler; Nigel H Lovell
Journal:  Med Biol Eng Comput       Date:  2011-02-22       Impact factor: 2.602

5.  Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique.

Authors:  L Nilsson; A Johansson; S Kalman
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

6.  Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters.

Authors:  Marco A F Pimentel; Alistair E W Johnson; Peter H Charlton; Drew Birrenkott; Peter J Watkinson; Lionel Tarassenko; David A Clifton
Journal:  IEEE Trans Biomed Eng       Date:  2016-11-18       Impact factor: 4.538

7.  Ambient temperature effect on pulse rate variability as an alternative to heart rate variability in young adult.

Authors:  Hangsik Shin
Journal:  J Clin Monit Comput       Date:  2015-10-28       Impact factor: 2.502

Review 8.  Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review.

Authors:  Peter H Charlton; Drew A Birrenkott; Timothy Bonnici; Marco A F Pimentel; Alistair E W Johnson; Jordi Alastruey; Lionel Tarassenko; Peter J Watkinson; Richard Beale; David A Clifton
Journal:  IEEE Rev Biomed Eng       Date:  2017-10-24