Literature DB >> 12803288

Respiratory variations in the reflection mode photoplethysmographic signal. Relationships to peripheral venous pressure.

L Nilsson1, A Johansson, S Kalman.   

Abstract

Photoplethysmography (PPG) is a non-invasive optical way of measuring variations in blood volume and perfusion in the tissue, used in pulse oximetry for instance. Respiratory-induced intensity variations (RIIVs) in the PPG signal exist, but the physiological background is not fully understood. Respiration causes variations in the blood volume in the peripheral vascular bed. It was hypothesised that the filling of peripheral veins is one of the important factors involved. In 16 healthy subjects, the respiratory synchronous variations from a PPG reflection mode signal and the peripheral venous pressure (PVP) were recorded. Variations of tidal volume, respiratory rate and contribution from abdominal and thoracic muscles gave significant and similar amplitude changes in both RIIV and the respiratory variation of PVP (p<0.01). The highest amplitudes of both signals were found at the largest tidal volume, lowest respiratory rate and during mainly thoracic breathing, respectively. The coherence between PVP and RIIV signals was high, the median (quartile range) being 0.78 (0.42). Phase analysis showed that RIIV was usually leading PVP, but variations between subjects were large. Although respiratory-induced variations in PVP and PPG showed a close correlation in amplitude variation, a causal relationship between the signals could not be demonstrated.

Entities:  

Mesh:

Year:  2003        PMID: 12803288     DOI: 10.1007/bf02348428

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  24 in total

1.  Effect of respiratory movements on superior cava flow under normal and abnormal conditions.

Authors:  G A BRECHER; G MIXTER
Journal:  Am J Physiol       Date:  1953-02

2.  Respiratory sinus arrhythmia. A phenomenon improving pulmonary gas exchange and circulatory efficiency.

Authors:  J Hayano; F Yasuma; A Okada; S Mukai; T Fujinami
Journal:  Circulation       Date:  1996-08-15       Impact factor: 29.690

3.  Autonomic control of skin microvessels: assessment by power spectrum of photoplethysmographic waves.

Authors:  L Bernardi; A Radaelli; P L Solda; A J Coats; M Reeder; A Calciati; C S Garrard; P Sleight
Journal:  Clin Sci (Lond)       Date:  1996-05       Impact factor: 6.124

4.  Spectral analysis of AC and DC components of the pulse photoplethysmograph at rest and during induction of anaesthesia.

Authors:  P D Larsen; M Harty; M Thiruchelvam; D C Galletly
Journal:  Int J Clin Monit Comput       Date:  1997

5.  The relationship between active constriction and passive recoil of the veins at various distending pressures.

Authors:  B Oberg
Journal:  Acta Physiol Scand       Date:  1967 Oct-Nov

6.  Photoelectric plethysmography--some fundamental aspects of the reflection and transmission method.

Authors:  J A Nijboer; J C Dorlas; H F Mahieu
Journal:  Clin Phys Physiol Meas       Date:  1981-08

7.  Fluctuations in blood flow to acral skin in humans: connection with heart rate and blood pressure variability.

Authors:  K Lossius; M Eriksen; L Walløe
Journal:  J Physiol       Date:  1993-01       Impact factor: 5.182

8.  Influence of lung volume on sympathetic nerve discharge in normal humans.

Authors:  D R Seals; N O Suwarno; J A Dempsey
Journal:  Circ Res       Date:  1990-07       Impact factor: 17.367

9.  Use of pulse oximetry as a noninvasive indicator of intravascular volume status.

Authors:  B L Partridge
Journal:  J Clin Monit       Date:  1987-10

10.  Buffering of respiratory variations in venous return by right ventricle: a theoretical analysis.

Authors:  W P Santamore; J N Amoore
Journal:  Am J Physiol       Date:  1994-12
View more
  10 in total

1.  Age and gender do not influence the ability to detect respiration by photoplethysmography.

Authors:  Lena Nilsson; Tomas Goscinski; Anders Johansson; Lars-Göran Lindberg; Sigga Kalman
Journal:  J Clin Monit Comput       Date:  2006-10-11       Impact factor: 2.502

2.  Fingertip photoplethysmographic waveform variability and systemic vascular resistance in intensive care unit patients.

Authors:  Paul M Middleton; Gregory S H Chan; Elizabeth Steel; Philip Malouf; Christopher Critoph; Gordon Flynn; Emma O'Lone; Branko G Celler; Nigel H Lovell
Journal:  Med Biol Eng Comput       Date:  2011-02-22       Impact factor: 2.602

3.  Respiratory variations in the photoplethysmographic waveform amplitude depend on type of pulse oximetry device.

Authors:  Lars Øivind Høiseth; Ingrid Elise Hoff; Ove Andreas Hagen; Knut Arvid Kirkebøen; Svein Aslak Landsverk
Journal:  J Clin Monit Comput       Date:  2015-06-12       Impact factor: 2.502

4.  Robust respiration detection from remote photoplethysmography.

Authors:  Mark van Gastel; Sander Stuijk; Gerard de Haan
Journal:  Biomed Opt Express       Date:  2016-11-03       Impact factor: 3.732

5.  Non-invasive estimation of systolic blood pressure and diastolic blood pressure using photoplethysmograph components.

Authors:  Incheol Jeong; Sukhwan Jun; Daeja Um; Joonghwan Oh; Hyungro Yoon
Journal:  Yonsei Med J       Date:  2010-05       Impact factor: 2.759

6.  Validation of forehead venous pressure as a measure of respiratory effort for the diagnosis of sleep apnea.

Authors:  Djordje Popovic; Christopher King; Melanie Guerrero; Daniel J Levendowski; Delmer Henninger; Philip R Westbrook
Journal:  J Clin Monit Comput       Date:  2008-12-31       Impact factor: 2.502

7.  Comparison of non-invasive peripheral venous saturations with venous blood co-oximetry.

Authors:  A M Belhaj; J P Phillips; P A Kyriacou; R M Langford
Journal:  J Clin Monit Comput       Date:  2016-11-21       Impact factor: 2.502

Review 8.  Fluid responsiveness in the pediatric population.

Authors:  Ji-Hyun Lee; Eun-Hee Kim; Young-Eun Jang; Hee-Soo Kim; Jin-Tae Kim
Journal:  Korean J Anesthesiol       Date:  2019-10-01

Review 9.  Photoplethysmogram Analysis and Applications: An Integrative Review.

Authors:  Junyung Park; Hyeon Seok Seok; Sang-Su Kim; Hangsik Shin
Journal:  Front Physiol       Date:  2022-03-01       Impact factor: 4.566

10.  PPG EduKit: An Adjustable Photoplethysmography Evaluation System for Educational Activities.

Authors:  Ángel Solé Morillo; Joan Lambert Cause; Vlad-Eusebiu Baciu; Bruno da Silva; Juan C Garcia-Naranjo; Johan Stiens
Journal:  Sensors (Basel)       Date:  2022-02-11       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.