Literature DB >> 9336161

Surface applicators for high dose rate brachytherapy in AIDS-related Kaposi's sarcoma.

M D Evans1, M Yassa, E B Podgorsak, T N Roman, L J Schreiner, L Souhami.   

Abstract

PURPOSE: The development of commercially available surface applicators using high dose rate remote afterloading devices has enabled radiotherapy centers to treat selected superficial lesions using a remote afterloading brachytherapy unit. The dosimetric parameters of these applicators, the clinical implementation of this technique, and a review of the initial patient treatment regimes are presented. METHODS AND MATERIALS: A set of six fixed-diameter (1, 2, and 3 cm), tungsten/steel surface applicators is available for use with a single stepping-source (Ir-192, 370 GBq) high dose rate afterloader. The source can be positioned either in a parallel or perpendicular orientation to the treatment plane at the center of a conical aperture that sits at an SSD of approximately 15 mm and is used with a 1-mm thick removable plastic cap. The surface dose rates, percent depth dose, and off-axis ratios were measured. A custom-built, ceiling-mounted immobilization device secures the applicator on the surface of the patient's lesion during treatment.
RESULTS: Between November 1994, and September 1996, 16 AIDS-related Kaposi's sarcoma patients having a total of 120 lesions have been treated with palliative intent. Treatment sites were distributed between the head and neck, extremity, and torso. Doses ranged from 8 to 20 Gy, with a median dose of 10 Gy delivered in a single fraction. Treatments were well tolerated with minimal skin reaction, except for patients with lesions treated to 20 Gy who developed moderate/severe desquamation.
CONCLUSION: Radiotherapy centers equipped with a high dose rate remote afterloading unit may treat small selected surface lesions with commercially available surface applicators. These surface applicators must be used with a protective cap to eliminate electron contamination. The optimal surface dose appears to be either 10 or 15 Gy depending upon the height of the lesion.

Entities:  

Mesh:

Year:  1997        PMID: 9336161     DOI: 10.1016/s0360-3016(97)00360-x

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  11 in total

Review 1.  The significance of oral health in HIV disease.

Authors:  I L Chapple; J Hamburger
Journal:  Sex Transm Infect       Date:  2000-08       Impact factor: 3.519

2.  Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part II. High dose rate 192Ir sources.

Authors:  Regina K Fulkerson; John A Micka; Larry A DeWerd
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

3.  Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source.

Authors:  Regina K Fulkerson; John A Micka; Larry A DeWerd
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

4.  [The indications for and results of HDR afterloading therapy in diseases of the skin and mucosa with standardized surface applicators (the Leipzig applicator)].

Authors:  A Köhler-Brock; W Prager; S Pohlmann; S Kunze
Journal:  Strahlenther Onkol       Date:  1999-04       Impact factor: 3.621

5.  Dosimetric characteristics of a new unit for electronic skin brachytherapy.

Authors:  Teresa Garcia-Martinez; Jan-Pieter Chan; Jose Perez-Calatayud; Facundo Ballester
Journal:  J Contemp Brachytherapy       Date:  2014-02-19

6.  Depth determination of skin cancers treated with superficial brachytherapy: ultrasound vs. histopathology.

Authors:  Rosa Ballester-Sánchez; Olga Pons-Llanas; Margarita Llavador-Ros; Rafael Botella-Estrada; Antonio Ballester-Cuñat; Alejandro Tormo-Micó; Francisco Javier Celadá-Álvarez; Silvia Rodríguez-Villalba; Manuel Santos-Ortega; Facundo Ballester-Pallarés; Jose Perez-Calatayud
Journal:  J Contemp Brachytherapy       Date:  2014-12-31

7.  Dosimetric evaluation of internal shielding in a high dose rate skin applicator.

Authors:  Françoise Lliso; Domingo Granero; Jose Perez-Calatayud; Vicente Carmona; M Carmen Pujades; Facundo Ballester
Journal:  J Contemp Brachytherapy       Date:  2011-03-31

8.  Malignant soft tissue sarcoma of the shoulder treated by surface mould brachytherapy boost in an adjuvant setting.

Authors:  Ashutosh Mukherji; Mourougan Sinnatamby
Journal:  J Contemp Brachytherapy       Date:  2017-04-26

9.  Non-melanoma skin cancer treated with HDR Valencia applicator: clinical outcomes.

Authors:  Alejandro Tormo; Francisco Celada; Silvia Rodriguez; Rafael Botella; Antonio Ballesta; Michael Kasper; Zoubir Ouhib; Manuel Santos; Jose Perez-Calatayud
Journal:  J Contemp Brachytherapy       Date:  2014-06-03

10.  Varian HDR surface applicators - commissioning and clinical implementation.

Authors:  Ileana Iftimia; Andrea B McKee; Per H Halvorsen
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.