Shelf life and in vivo duration. Impacts on performance of tibial bearings.

B H Currier1, J H Currier, J P Collier, M B Mayor, R D Scott.   

Abstract

Polyethylene has been used for more than 30 years as an orthopaedic bearing material; however, recently concern has been focused on the early failure of some polyethylene bearings. The damage seen in some bearings has been linked to gamma radiation sterilization performed in an air environment. Gamma sterilization in air has been documented to cause an increase in oxidation and degradation of mechanical properties that continue with time. However, not all retrieved bearings that are gamma sterilized in air exhibit the elevated oxidation and mechanical property degradation that lead to early component failure. Bearings that are gamma sterilized in air oxidize while sitting in inventory before implantation. Shelf oxidation rate was estimated based on analysis of a series of never implanted tibial bearings. This shelf oxidation rate allowed estimation of in vivo oxidation for retrieved tibial bearings of known sterilization date. Bearings with less than 1 year of shelf life after gamma sterilization in air had lower in vivo oxidation and better in vivo performance than did those with longer shelf life before implantation. Shelf time before implantation appears to be a significant factor in the success or failure of bearings that are gamma sterilized in air.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9308533

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  12 in total

1.  The influence of gamma irradiation and aging on degradation mechanisms of ultra-high molecular weight polyethylene.

Authors:  F J Buchanan; J R White; B Sim; S Downes
Journal:  J Mater Sci Mater Med       Date:  2001-01       Impact factor: 3.896

2.  In vivo oxidation contributes to delamination but not pitting in polyethylene components for total knee arthroplasty.

Authors:  Francisco J Medel; Steven M Kurtz; Javad Parvizi; Gregg R Klein; Matthew J Kraay; Clare M Rimnac
Journal:  J Arthroplasty       Date:  2010-09-28       Impact factor: 4.757

3.  Oxidation and wear of 100-Mrad cross-linked polyethylene shelf-aged for 30 years.

Authors:  Hironobu Oonishi; Sok Chol Kim; Hiroyuki Oonishi; Masayuki Kyomoto; Shingo Masuda
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

4.  Gamma inert sterilization: a solution to polyethylene oxidation?

Authors:  Francisco J Medel; Steven M Kurtz; William J Hozack; Javad Parvizi; James J Purtill; Peter F Sharkey; Daniel MacDonald; Matthew J Kraay; Victor Goldberg; Clare M Rimnac
Journal:  J Bone Joint Surg Am       Date:  2009-04       Impact factor: 5.284

5.  On the assessment of oxidative and microstructural changes after in vivo degradation of historical UHMWPE knee components by means of vibrational spectroscopies and nanoindentation.

Authors:  Francisco J Medel; Clare M Rimnac; Steven M Kurtz
Journal:  J Biomed Mater Res A       Date:  2009-05       Impact factor: 4.396

6.  Does increased topside conformity in modular total knee arthroplasty lead to increased backside wear?

Authors:  Ran Schwarzkopf; Richard D Scott; Evan M Carlson; John H Currier
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

7.  Gamma-irradiation sterilization in an inert environment: a partial solution.

Authors:  Daniel J Berry; Barbara H Currier; Michael B Mayor; John P Collier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

8.  Crosslink Density Is Reduced and Oxidation Is Increased in Retrieved Highly Crosslinked Polyethylene TKA Tibial Inserts.

Authors:  Tong Liu; Christina I Esposito; Jayme C Burket; Timothy M Wright
Journal:  Clin Orthop Relat Res       Date:  2017-01       Impact factor: 4.176

9.  Polyethylene oxidation in total hip arthroplasty: evolution and new advances.

Authors:  Enrique Gómez-Barrena; Francisco Medel; José Antonio Puértolas
Journal:  Open Orthop J       Date:  2009-12-24

Review 10.  Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior.

Authors:  M C Sobieraj; C M Rimnac
Journal:  J Mech Behav Biomed Mater       Date:  2008-12-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.