Literature DB >> 9294748

The mechanical role of laminar hook protection of pedicle screws at the caudal end vertebra.

J Y Margulies1, R S Casar, S A Caruso, M G Neuwirth, T R Haher.   

Abstract

Biomechanical studies have shown hooks to be superior to pedicle screws in pull-out, especially in osteoporosis. This study evaluates the possible increase in stiffness of pedicle screws provided by laminar hooks while applying non-destructive forces to a vertebrectomy model assembled with Compact Cotrel Dubousset (CCD) instrumentation. Synthetic vertebrae were employed in a three-level vertebrectomy model. CCD screw-based three-level constructs with and without sublaminar hooks in the caudal element were tested in flexion, extension, compression, lateral bending, and torsion. There was no statistically significant advantage in adding inferior laminar hooks to a caudal end vertebra that had bilateral pedicle screws in any of the testing modes. Torsional stability, however, was augmented, but not significantly. Torsional instability and osteoporotic bone may be the clinical justifications for adding laminar hooks below screws in the caudal end vertebra.

Entities:  

Mesh:

Year:  1997        PMID: 9294748      PMCID: PMC3454646          DOI: 10.1007/BF01322446

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  15 in total

1.  Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires.

Authors:  J D Coe; K E Warden; M A Herzig; P C McAfee
Journal:  Spine (Phila Pa 1976)       Date:  1990-09       Impact factor: 3.468

2.  Survivorship analysis of VSP spine instrumentation in the treatment of thoracolumbar and lumbar burst fractures.

Authors:  D K Ebelke; M A Asher; J R Neff; D P Kraker
Journal:  Spine (Phila Pa 1976)       Date:  1991-08       Impact factor: 3.468

3.  Cotrel-Dubousset instrumentation for the treatment of thoracolumbar fractures.

Authors:  D B Moreland; J G Egnatchik; G J Bennett
Journal:  Neurosurgery       Date:  1990-07       Impact factor: 4.654

4.  Biomechanical analysis of pedicle screw instrumentation systems in a corpectomy model.

Authors:  R B Ashman; R D Galpin; J D Corin; C E Johnston
Journal:  Spine (Phila Pa 1976)       Date:  1989-12       Impact factor: 3.468

5.  Kinematics of the lumbar spine following pedicle screw plate fixation.

Authors:  N Yoganandan; F Pintar; D J Maiman; J Reinartz; A Sances; S J Larson; J F Cusick
Journal:  Spine (Phila Pa 1976)       Date:  1993-03-15       Impact factor: 3.468

6.  Short segment transpedicular Cotrel-Dubousset instrumentation: a porcine corpectomy model.

Authors:  G C Stephens; D P Devito; M J McNamara; D M Spengler
Journal:  J Spinal Disord       Date:  1993-06

7.  Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members.

Authors:  S I Esses; B L Sachs; V Dreyzin
Journal:  Spine (Phila Pa 1976)       Date:  1993-11       Impact factor: 3.468

8.  Static and cyclical biomechanical analysis of pedicle screw spinal constructs.

Authors:  B W Cunningham; J C Sefter; Y Shono; P C McAfee
Journal:  Spine (Phila Pa 1976)       Date:  1993-09-15       Impact factor: 3.468

9.  A comparative biomechanical study of spinal fixation using Cotrel-Dubousset instrumentation.

Authors:  J P Farcy; M Weidenbaum; C B Michelsen; D A Hoeltzel; K A Athanasiou
Journal:  Spine (Phila Pa 1976)       Date:  1987-11       Impact factor: 3.468

10.  Transpedicular instrumentation and short-segment fusion of thoracolumbar fractures: a prospective study using a single instrumentation system.

Authors:  D L Kramer; W B Rodgers; F L Mansfield
Journal:  J Orthop Trauma       Date:  1995       Impact factor: 2.512

View more
  1 in total

1.  Biomechanical comparison of different combinations of hook and screw in one spine motion unit--an experiment in porcine model.

Authors:  Ching-Lung Tai; Li-Huei Chen; De-Mei Lee; Mu-Yi Liu; Po-Liang Lai
Journal:  BMC Musculoskelet Disord       Date:  2014-06-09       Impact factor: 2.362

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.