Literature DB >> 9263002

Registration of head volume images using implantable fiducial markers.

C R Maurer1, J M Fitzpatrick, M Y Wang, R L Galloway, R J Maciunas, G S Allen.   

Abstract

In this paper, we describe an extrinsic-point-based, interactive image-guided neurosurgical system designed at Vanderbilt University, Nashville, TN, as part of a collaborative effort among the Departments of Neurological Surgery, Computer Science, and Biomedical Engineering. Multimodal image-to-image (II) and image-to-physical (IP) registration is accomplished using implantable markers. Physical space tracking is accomplished with optical triangulation. We investigate the theoretical accuracy of point-based registration using numerical simulations, the experimental accuracy of our system using data obtained with a phantom, and the clinical accuracy of our system using data acquired in a prospective clinical trial by six neurosurgeons at four medical centers from 158 patients undergoing craniotomies to resect cerebral lesions. We can determine the position of our markers with an error of approximately 0.4 mm in X-ray computed tomography (CT) and magnetic resonance (MR) images and 0.3 mm in physical space. The theoretical registration error using four such markers distributed around the head in a configuration that is clinically practical is approximately 0.5-0.6 mm. The mean CT-physical registration error for the phantom experiments is 0.5 mm and for the clinical data obtained with rigid head fixation during scanning is 0.7 mm. The mean CT-MR registration error for the clinical data obtained without rigid head fixation during scanning is 1.4 mm, which is the highest mean error that we observed. These theoretical and experimental findings indicate that this system is an accurate navigational aid that can provide real-time feedback to the surgeon about anatomical structures encountered in the surgical field.

Entities:  

Mesh:

Year:  1997        PMID: 9263002     DOI: 10.1109/42.611354

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  73 in total

1.  Cortical surface registration for image-guided neurosurgery using laser-range scanning.

Authors:  Michael I Miga; Tuhin K Sinha; David M Cash; Robert L Galloway; Robert J Weil
Journal:  IEEE Trans Med Imaging       Date:  2003-08       Impact factor: 10.048

2.  Incorporation of a laser range scanner into image-guided liver surgery: surface acquisition, registration, and tracking.

Authors:  David M Cash; Tuhin K Sinha; William C Chapman; Hiromi Terawaki; Benoit M Dawant; Robert L Galloway; Michael I Miga
Journal:  Med Phys       Date:  2003-07       Impact factor: 4.071

Review 3.  Computer-aided navigation in neurosurgery.

Authors:  P Grunert; K Darabi; J Espinosa; R Filippi
Journal:  Neurosurg Rev       Date:  2003-05       Impact factor: 3.042

4.  Registration of 3D CT angiography and cardiac MR images in coronary artery disease patients.

Authors:  Bernhard Sturm; Kimerly A Powell; Arthur E Stillman; Richard D White
Journal:  Int J Cardiovasc Imaging       Date:  2003-08       Impact factor: 2.357

5.  An imaging co-registration system using novel non-invasive and non-radioactive external markers.

Authors:  Tung-Hsin Wu; Jiunn-Kuen Wang; Jason J S Lee; Ren-Shyan Liu; Wan-Yuo Guo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-12       Impact factor: 9.236

6.  [3-D navigation in the petrous bone with submillimeter accuracy].

Authors:  F Kral; W Freysinger
Journal:  HNO       Date:  2004-08       Impact factor: 1.284

7.  Marker-free registration for the accurate integration of CT images and the subject's anatomy during navigation surgery of the maxillary sinus.

Authors:  S-H Kang; M-K Kim; J-H Kim; H-K Park; W Park
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

8.  Surgical and Interventional Robotics: Core Concepts, Technology, and Design.

Authors:  Peter Kazanzides; Gabor Fichtinger; Gregory D Hager; Allison M Okamura; Louis L Whitcomb; Russell H Taylor
Journal:  IEEE Robot Autom Mag       Date:  2008-06-01       Impact factor: 5.143

9.  New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: system description and validation.

Authors:  Laurence Mercier; Rolando F Del Maestro; Kevin Petrecca; Anna Kochanowska; Simon Drouin; Charles X B Yan; Andrew L Janke; Sean Jy-Shyang Chen; D Louis Collins
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-10-01       Impact factor: 2.924

10.  Regional-surface-based registration for image-guided neurosurgery: effects of scan modes on registration accuracy.

Authors:  Yuan Dong; Chenxi Zhang; Dafeng Ji; Manning Wang; Zhijian Song
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-05-04       Impact factor: 2.924

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.