Literature DB >> 9252272

Mutual Inductance in the Bird-Cage Resonator

.   

Abstract

Formulas are derived to account for the effect of the mutual inductances, between all meshes, upon the electrical resonance spectra bird-cage resonators, and similar structures such as the TEM resonator of P. K. H. Roschmann (United States Patent 4,746,866) and J. T. Vaughan et al. (Magn. Reson. Med. 32, 206, 1994). The equations are parameterized in terms of isolated mesh frequencies and coupling coefficients, and ought therefore apply not only to simple magnetic couplings used in the derivation, but to electromagnetic couplings as well. A method for measuring the coupling coefficients-applicable to shielded as well as unshielded resonators-is described, based upon the splitting of frequencies in pairs of coupled resonators; and detailed comparisons are given between calculated and measured resonance spectra: for bird-cage resonators, with and without shields, and for the TEM resonator.

Entities:  

Year:  1997        PMID: 9252272     DOI: 10.1006/jmre.1997.1149

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  5 in total

1.  A fast and accurate simulator for the design of birdcage coils in MRI.

Authors:  Giulio Giovannetti; Luigi Landini; Maria Filomena Santarelli; Vincenzo Positano
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

2.  Comparison of Four Different Shields for Birdcage-Type Coils with Experiments and Numerical Calculations.

Authors:  Wanzhan Liu; Shutong Zhang; Christopher M Collins; Jianli Wang; Michael B Smith
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2006-10-09       Impact factor: 1.176

3.  4T split TEM volume head and knee coils for improved sensitivity and patient accessibility.

Authors:  Nikolai I Avdievich; Ken Bradshaw; Jing-Huei Lee; Andrey M Kuznetsov; Hoby P Hetherington
Journal:  J Magn Reson       Date:  2007-05-16       Impact factor: 2.229

4.  Resonant inductive decoupling (RID) for transceiver arrays to compensate for both reactive and resistive components of the mutual impedance.

Authors:  Nikolai I Avdievich; Jullie W Pan; Hoby P Hetherington
Journal:  NMR Biomed       Date:  2013-06-18       Impact factor: 4.044

5.  Short echo spectroscopic imaging of the human brain at 7T using transceiver arrays.

Authors:  N I Avdievich; J W Pan; J M Baehring; D D Spencer; H P Hetherington
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.