Literature DB >> 9250752

Preoperative factors influencing the range of movement after total knee arthroplasty for severe osteoarthritis.

A Lizaur1, L Marco, R Cebrian.   

Abstract

We report a prospective study, using multivariate analysis, of the factors which influence the range of movement after total knee arthroplasty in 74 patients with 83 arthroplasties at a mean follow-up of 23.6 months (12 to 41). All the patients had a diagnosis of osteoarthritis, a severely disabled knee with a Knee Society system score of less than 60, varus deformity, no previous surgery to the knee, identical prostheses implanted with a similar surgical technique, and no postoperative complications which may have affected the range of movement. The most important factors which influenced the range of movement after arthroplasty were the preoperative range of flexion and the body-weight of the patient. There was a significant improvement in flexion and reduction of flexion contracture at each successive review up to 12 months after operation. Patients with restricted movement before operation showed a satisfactory gain at final review.

Entities:  

Mesh:

Year:  1997        PMID: 9250752     DOI: 10.1302/0301-620x.79b4.7242

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  40 in total

1.  Significant effect of the posterior tibial slope and medial/lateral ligament balance on knee flexion in total knee arthroplasty.

Authors:  Eisaku Fujimoto; Yoshiaki Sasashige; Yasuji Masuda; Takashi Hisatome; Akio Eguchi; Tetsuo Masuda; Mikiya Sawa; Yoshinori Nagata
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-30       Impact factor: 4.342

2.  No difference in ROM and knee function between mobile and floating platforms in TKA.

Authors:  Johannes Holinka; Navid Bahrami; Richard Lass; Sophie Frantal; Reinhard Windhager; Hugo Axel Wanivenhaus
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-29       Impact factor: 4.342

3.  Can a high-flexion total knee arthroplasty relieve pain and restore function without premature failure?

Authors:  Ryan D Bauman; Derek R Johnson; Travis J Menge; Raymond H Kim; Douglas A Dennis
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

4.  The influence of tibial slope on maximal flexion after total knee arthroplasty.

Authors:  J Bellemans; F Robijns; J Duerinckx; S Banks; H Vandenneucker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-10-26       Impact factor: 4.342

5.  Residual posterior femoral condyle osteophyte affects the flexion range after total knee replacement.

Authors:  W P Yau; K Y Chiu; W M Tang; T P Ng
Journal:  Int Orthop       Date:  2005-09-16       Impact factor: 3.075

6.  Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery.

Authors:  Seong Il Bin; Tae Seok Nam
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-10-28       Impact factor: 4.342

7.  Tibiofemoral contact areas and pressures in six high flexion knees.

Authors:  Kei Shiramizu; Frank Vizesi; Warwick Bruce; Sebastian Herrmann; William R Walsh
Journal:  Int Orthop       Date:  2007-11-22       Impact factor: 3.075

8.  Influence of intra-operative joint gap on post-operative flexion angle in osteoarthritis patients undergoing posterior-stabilized total knee arthroplasty.

Authors:  Tomoyuki Matsumoto; Kiyonori Mizuno; Hirotsugu Muratsu; Nobuhiro Tsumura; Naomasa Fukase; Seiji Kubo; Shinichi Yoshiya; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-04-25       Impact factor: 4.342

9.  Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system.

Authors:  Daniela Casino; Stefano Zaffagnini; Sandra Martelli; Nicola Lopomo; Simone Bignozzi; Francesco Iacono; Alessandro Russo; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-12-20       Impact factor: 4.342

10.  Does TKA improve functional outcome and range of motion in patients with stiff knees?

Authors:  Young-Hoo Kim; Jun-Shik Kim
Journal:  Clin Orthop Relat Res       Date:  2008-08-20       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.