Literature DB >> 22744436

No difference in ROM and knee function between mobile and floating platforms in TKA.

Johannes Holinka1, Navid Bahrami, Richard Lass, Sophie Frantal, Reinhard Windhager, Hugo Axel Wanivenhaus.   

Abstract

PURPOSE: The purpose of this study was to determine whether the floating platforms (FP) were superior to rotating platforms (RP) in computer-navigated total knee arthroplasty (TKA) comparing the range of motion (ROM) as well as clinical and subjective function of the knee.
METHODS: This retrospective non-randomized single-centre cohort study includes 255 patients with a primary implanted computer-navigated e.motion™ (Aesculap B. Braun) TKA system, implanted because of clinical and radiological verified gonarthrosis. In 129 patients, the FP platform was implanted, and in 126 patients, the RP platform. As statistical procedures for differences between inlay type RP/FP in ROM and Knee Society Score (KSS) after 3- and 24-month follow-up, an analysis of covariance (with risk factors gender, age, BMI, preoperative ROM and preoperative KSS) was performed.
RESULTS: Although preoperative ROM and knee society function score (KSS part II) were significantly higher in the FP group before surgery, there was no significant difference between RP and FP in ROM and KSS at 3- and 24-month follow-up.
CONCLUSION: The FP platform design did not have an advantage in ROM as well as in clinical and subjective knee function compared with the RP platform in computer-navigated TKA neither in early follow-up examinations at 3 months postoperatively nor at long-time follow-up at 24 months postoperatively.

Entities:  

Mesh:

Year:  2012        PMID: 22744436     DOI: 10.1007/s00167-012-2117-0

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  28 in total

1.  [Navigation in knee endoprosthesis implantation--preliminary experiences and prospective comparative study with conventional implantation technique].

Authors:  R K Mielke; U Clemens; J H Jens; S Kershally
Journal:  Z Orthop Ihre Grenzgeb       Date:  2001 Mar-Apr

2.  [Navigated implantation of total knee endoprostheses--a comparative study with conventional instrumentation].

Authors:  J Y Jenny; C Boeri
Journal:  Z Orthop Ihre Grenzgeb       Date:  2001 Mar-Apr

3.  Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients.

Authors:  S David Stulberg; Peter Loan; Vineet Sarin
Journal:  J Bone Joint Surg Am       Date:  2002       Impact factor: 5.284

4.  Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; D Zurakowski; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2004-07

5.  Functional outcome after computer-assisted versus conventional total knee arthroplasty: a randomized controlled study.

Authors:  Jörg Lützner; Klaus-Peter Günther; Stephan Kirschner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-05       Impact factor: 4.342

6.  Preoperative factors influencing the range of movement after total knee arthroplasty for severe osteoarthritis.

Authors:  A Lizaur; L Marco; R Cebrian
Journal:  J Bone Joint Surg Br       Date:  1997-07

7.  Navigated total knee replacement. A meta-analysis.

Authors:  Kai Bauwens; Gerrit Matthes; Michael Wich; Florian Gebhard; Beate Hanson; Axel Ekkernkamp; Dirk Stengel
Journal:  J Bone Joint Surg Am       Date:  2007-02       Impact factor: 5.284

8.  Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection.

Authors:  Dae-Hee Lee; Jong-Hoon Park; Dong-Ik Song; Debabrata Padhy; Woong-Kyo Jeong; Seung-Beom Han
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-03       Impact factor: 4.342

9.  In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties.

Authors:  S A Banks; G D Markovich; W A Hodge
Journal:  J Arthroplasty       Date:  1997-04       Impact factor: 4.757

10.  Early clinical outcomes of floating platform mobile-bearing TKA: longitudinal comparison with fixed-bearing TKA.

Authors:  Tae Kyun Kim; Chong Bum Chang; Yeon Gwi Kang; Byung June Chung; Hyung Joon Cho; Sang Cheol Seong
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-11-28       Impact factor: 4.342

View more
  1 in total

1.  Comparison of fixed- and mobile-bearing total knee arthroplasty with a mean five-year follow-up: A meta-analysis.

Authors:  Mengqi Cheng; Desheng Chen; Yongyuan Guo; Chen Zhu; Xianlong Zhang
Journal:  Exp Ther Med       Date:  2013-05-17       Impact factor: 2.447

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.