Literature DB >> 9246615

Accurate mass measurements using MALDI-TOF with delayed extraction.

E J Takach1, W M Hines, D H Patterson, P Juhasz, A M Falick, M L Vestal, S A Martin.   

Abstract

Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry is now an essential tool in biopolymer analysis. Sensitivity and mass range are unsurpassed, but mass measurement accuracy and resolution have been limited. With delayed extraction and a reflecting analyzer, mass measurements using MALDI-TOF can be made with an accuracy of a few parts per million (ppm). It is possible to distinguish Lys from Gln in peptides, and to determine the elemental composition of smaller molecules (mass 100-500). In database searching strategies, a smaller mass window, resulting from an increase in mass accuracy, greatly decreases the number of possible candidates. Mass measurement accuracy with errors less than 5 ppm is demonstrated on a mixture of 12 peptides ranging in mass from ca. 900 to 3700 Da. Mass measurements on 13 peaks in an unseparated tryptic digest of myoglobin gave results with an overall average error less than 3.5 ppm, with a maximum error of 7 ppm.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9246615     DOI: 10.1023/a:1026376403468

Source DB:  PubMed          Journal:  J Protein Chem        ISSN: 0277-8033


  14 in total

1.  Detection of bacteriocins by matrix-assisted laser Desorption/Ionization time-of-flight mass spectrometry

Authors: 
Journal:  Appl Environ Microbiol       Date:  1999-05       Impact factor: 4.792

2.  Measurements of mean initial velocities of analyte and matrix ions in infrared matrix-assisted laser desorption ionization mass spectrometry.

Authors:  Stefan Berkenkamp; Christoph Menzel; Franz Hillenkamp; Klaus Dreisewerd
Journal:  J Am Soc Mass Spectrom       Date:  2002-03       Impact factor: 3.109

Review 3.  Mass spectrometry innovations in drug discovery and development.

Authors:  D I Papac; Z Shahrokh
Journal:  Pharm Res       Date:  2001-02       Impact factor: 4.200

4.  Practical quantitative biomedical applications of MALDI-TOF mass spectrometry.

Authors:  Martin Bucknall; Kim Y C Fung; Mark W Duncan
Journal:  J Am Soc Mass Spectrom       Date:  2002-09       Impact factor: 3.109

5.  An accurate and clean calibration method for MALDI-MS.

Authors:  Bosong Xiang; Mindy Prado
Journal:  J Biomol Tech       Date:  2010-09

6.  Improved mass accuracy for tandem mass spectrometry.

Authors:  Nathan K Kaiser; Gordon A Anderson; James E Bruce
Journal:  J Am Soc Mass Spectrom       Date:  2005-04       Impact factor: 3.109

Review 7.  Accurate mass measurements in proteomics.

Authors:  Tao Liu; Mikhail E Belov; Navdeep Jaitly; Wei-Jun Qian; Richard D Smith
Journal:  Chem Rev       Date:  2007-07-25       Impact factor: 60.622

Review 8.  Peptide and protein identification by matrix-assisted laser desorption ionization (MALDI) and MALDI-post-source decay time-of-flight mass spectrometry.

Authors:  P Chaurand; F Luetzenkirchen; B Spengler
Journal:  J Am Soc Mass Spectrom       Date:  1999-02       Impact factor: 3.109

9.  Automatic gain control in mass spectrometry using a jet disrupter electrode in an electrodynamic ion funnel.

Authors:  Jason S Page; Bogdan Bogdanov; Andrey N Vilkov; David C Prior; Michael A Buschbach; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-02       Impact factor: 3.109

10.  Investigation into accurate mass capability of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, with respect to radical ion species.

Authors:  Mark F Wyatt; Bridget K Stein; A Gareth Brenton
Journal:  J Am Soc Mass Spectrom       Date:  2006-03-15       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.