Literature DB >> 20808640

An accurate and clean calibration method for MALDI-MS.

Bosong Xiang1, Mindy Prado.   

Abstract

A new method for the mass calibration of the matrix-assisted laser desorption/ionization-mass spectrometry spectrum is introduced. This method achieves the same accuracy as that of internal calibration but without its drawbacks. The interference and signal suppression by calibration standard are avoided, and a pure/clean sample spectrum is obtained. No prior knowledge about the sample quantity is required for the calibration. The effectiveness of the method is demonstrated with protein identification data.

Keywords:  PMF; mass spectrometry

Mesh:

Year:  2010        PMID: 20808640      PMCID: PMC2922834     

Source DB:  PubMed          Journal:  J Biomol Tech        ISSN: 1524-0215


  12 in total

1.  Closely spaced external standard: a universal method of achieving 5 ppm mass accuracy over the entire MALDI plate in axial matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Authors:  Eugene Moskovets; Hsuan-Shen Chen; Anna Pashkova; Tomas Rejtar; Viktor Andreev; Barry L Karger
Journal:  Rapid Commun Mass Spectrom       Date:  2003       Impact factor: 2.419

2.  Use of matrix clusters and trypsin autolysis fragments as mass calibrants in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Authors:  William A Harris; Dariusz J Janecki; James P Reilly
Journal:  Rapid Commun Mass Spectrom       Date:  2002       Impact factor: 2.419

3.  A calibration method that simplifies and improves accurate determination of peptide molecular masses by MALDI-TOF MS.

Authors:  Johan Gobom; Martin Mueller; Volker Egelhofer; Dorothea Theiss; Hans Lehrach; Eckhard Nordhoff
Journal:  Anal Chem       Date:  2002-08-01       Impact factor: 6.986

4.  An improved two-step calibration method for matrix-assisted laser desorption/ionization time-of-flight mass spectra for proteomics.

Authors:  Marcus Bantscheff; Birgit Duempelfeld; Bernhard Kuster
Journal:  Rapid Commun Mass Spectrom       Date:  2002       Impact factor: 2.419

5.  Automated methods for improved protein identification by peptide mass fingerprinting.

Authors:  Fredrik Levander; Thorsteinn Rögnvaldsson; Jim Samuelsson; Peter James
Journal:  Proteomics       Date:  2004-09       Impact factor: 3.984

6.  Rapid identification of proteins by peptide-mass fingerprinting.

Authors:  D J Pappin; P Hojrup; A J Bleasby
Journal:  Curr Biol       Date:  1993-06-01       Impact factor: 10.834

7.  Calibration of matrix-assisted laser desorption/ionization time-of-flight peptide mass fingerprinting spectra.

Authors:  Karin Hjernø; Peter Højrup
Journal:  Methods Mol Biol       Date:  2007

8.  High-resolution matrix-assisted laser desorption/ionization in a linear time-of-flight mass spectrometer.

Authors:  R M Whittal; L Li
Journal:  Anal Chem       Date:  1995-07-01       Impact factor: 6.986

9.  Accurate mass measurements using MALDI-TOF with delayed extraction.

Authors:  E J Takach; W M Hines; D H Patterson; P Juhasz; A M Falick; M L Vestal; S A Martin
Journal:  J Protein Chem       Date:  1997-07

10.  Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons.

Authors:  M Karas; F Hillenkamp
Journal:  Anal Chem       Date:  1988-10-15       Impact factor: 6.986

View more
  4 in total

1.  Mass shift in mass spectrometry imaging: comprehensive analysis and practical corrective workflow.

Authors:  Andréa McCann; Sophie Rappe; Raphaël La Rocca; Mathieu Tiquet; Loïc Quinton; Gauthier Eppe; Johann Far; Edwin De Pauw; Christopher Kune
Journal:  Anal Bioanal Chem       Date:  2021-01-30       Impact factor: 4.142

2.  Optimizing sequence coverage for a moderate mass protein in nano-electrospray ionization quadrupole time-of-flight mass spectrometry.

Authors:  Ryan Matsuda; Venkata Kolli; Megan Woods; Eric D Dodds; David S Hage
Journal:  Anal Biochem       Date:  2016-06-16       Impact factor: 3.365

3.  Diagnosing and Correcting Mass Accuracy and Signal Intensity Error Due to Initial Ion Position Variations in a MALDI TOFMS.

Authors:  Brian J Malys; Michelle L Piotrowski; Kevin G Owens
Journal:  J Am Soc Mass Spectrom       Date:  2017-12-07       Impact factor: 3.109

4.  Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight (MALDI-TOF) Mass Spectrometry.

Authors:  Molly E Payne; Scott M Grayson
Journal:  J Vis Exp       Date:  2018-06-10       Impact factor: 1.355

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.