Literature DB >> 16540343

Investigation into accurate mass capability of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, with respect to radical ion species.

Mark F Wyatt1, Bridget K Stein, A Gareth Brenton.   

Abstract

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been shown to be an effective technique for the characterization of organometallic, coordination, and highly conjugated compounds. The preferred matrix is 2-[(2E)-3-(4-tert-butylphenyl)-2-methylprop-2-enylidene]malononitrile (DCTB), with radical ions observed. However, MALDI-TOFMS is generally not favored for accurate mass measurement. A specific method had to be developed for such compounds to assure the quality of our accurate mass results. Therefore, in this preliminary study, two methods of data acquisition, and both even-electron (EE+) ion and odd-electron (OE+.) radical ion mass calibration standards, have been investigated to establish the basic measurement technique. The benefit of this technique is demonstrated for a copper compound for which ions were observed by MALDI, but not by electrospray (ESI) or liquid secondary ion mass spectrometry (LSIMS); a mean mass accuracy error of -1.2 ppm was obtained.

Entities:  

Year:  2006        PMID: 16540343     DOI: 10.1016/j.jasms.2006.01.009

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  7 in total

1.  Intercomparison study on accurate mass measurement of small molecules in mass spectrometry.

Authors:  Anthony W T Bristow; Kenneth S Webb
Journal:  J Am Soc Mass Spectrom       Date:  2003-10       Impact factor: 3.109

2.  Cofacial porphyrin-ferrocene dyads and a new class of conjugated porphyrin.

Authors:  Andrew N Cammidge; Peter J Scaife; Gûlen Berber; David L Hughes
Journal:  Org Lett       Date:  2005-08-04       Impact factor: 6.005

3.  Accurate masses for structure confirmation.

Authors:  M L Gross
Journal:  J Am Soc Mass Spectrom       Date:  1994-02       Impact factor: 3.109

4.  Evaluation of matrix-assisted laser desorption ionization-time-of-flight mass measurement accuracy by using delayed extraction.

Authors:  R D Edmondson; D H Russell
Journal:  J Am Soc Mass Spectrom       Date:  1996-10       Impact factor: 3.109

5.  Accurate mass measurements using MALDI-TOF with delayed extraction.

Authors:  E J Takach; W M Hines; D H Patterson; P Juhasz; A M Falick; M L Vestal; S A Martin
Journal:  J Protein Chem       Date:  1997-07

6.  High resolution electrospray mass spectrometry with a magnetic sector instrument: accurate mass measurement and peptide sequencing.

Authors:  P A D'Agostino; J R Hancock; L R Provost; P D Semchuk; R S Hodges
Journal:  Rapid Commun Mass Spectrom       Date:  1995       Impact factor: 2.419

7.  Characterization of various analytes using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and 2-[(2E)-3-(4-tert-butylphenyl)-2-methylprop-2-enylidene]malononitrile matrix.

Authors:  Mark F Wyatt; Bridget K Stein; A Gareth Brenton
Journal:  Anal Chem       Date:  2006-01-01       Impact factor: 6.986

  7 in total
  1 in total

1.  Improved mass accuracy for higher mass peptides by using SWIFT excitation for MALDI-FTICR mass spectrometry.

Authors:  Li Jing; Chunyan Li; Richard L Wong; Desmond A Kaplan; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2007-10-30       Impact factor: 3.109

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.