Comparison of two Hologic DXA systems (QDR 1000 and QDR 4500/A).

N Barthe1, P Braillon, D Ducassou, B Basse-Cathalinat.   

Abstract

Bone mineral content is reliably measured by dual energy X-ray absorptiometry (DXA), if manufacturers' recommendations and quality control (QC) procedures are followed. Several phantoms (Hologic anthropomorphic spine phantom, the Groupe de Recherche et d'Informations sur les Osteoporoses (GRIO) test objects and the European semi-anthropomorphic phantoms) were used to evaluate reproducibility, linearity, accuracy and spatial resolution of two DXA devices in vitro. These parameters were also evaluated in vivo from measurements performed on 120 volunteer patients. It was found that when one device (a single beam monodetector QDR 1000) is replaced by another (a fan beam multidetector QDR 4500/A), the novel combination of procedures described here, ensures that the accuracy of DXA study results is maintained when both devices are used in succession for the same patient. To study the possible responses in clinical situations, the influence of bone environment (soft and adipose tissues) was also evaluated. In both systems, similar performances (in vitro coefficients of variation of 0.5%) were established. At extreme bone density values, slight differences in linearity were found, as well as differences in accuracy and spatial resolution. Lumbar spine and femoral neck measurements were performed with both systems in 120 volunteers, both measurements being made on the same day. The corresponding bone mineral density (BMD) values were highly correlated (r2 = 0.985 for lumbar spine and 0.948 for the femoral neck), and the mean BMD differences were 0.68% and 0.37% for each anatomical site, respectively. Although small, these differences add to the precision error of the method, which is near 1%. A calibration curve has to be obtained in order that both devices can be equally used in regular clinical study. We concluded that when a DXA system is replaced by a new one, appropriate QC procedures must be strictly observed.

Entities:  

Mesh:

Year:  1997        PMID: 9245885     DOI: 10.1259/bjr.70.835.9245885

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  24 in total

1.  Variations in diagnostic performances of dual-energy X-ray absorptiometry in the northwest of The Netherlands.

Authors:  Klaas P Staal; Jan C Roos; Radu A Manoliu; Piet J Kostense; Paul Lips
Journal:  Osteoporos Int       Date:  2003-11-20       Impact factor: 4.507

2.  The effect of room temperature on dual-energy X-ray absorptiometry.

Authors:  N L Culton; N A Pocock
Journal:  Osteoporos Int       Date:  2003-03-04       Impact factor: 4.507

3.  Image resolution and magnification using a cone beam densitometer: optimizing data acquisition for hip morphometric analysis.

Authors:  V Boudousq; D Mariano Goulart; J M Dinten; C Caderas de Kerleau; E Thomas; O Mares; P O Kotzki
Journal:  Osteoporos Int       Date:  2004-10-16       Impact factor: 4.507

4.  Marrow fat composition in anorexia nervosa.

Authors:  Miriam A Bredella; Pouneh K Fazeli; Scott M Daley; Karen K Miller; Clifford J Rosen; Anne Klibanski; Martin Torriani
Journal:  Bone       Date:  2014-06-19       Impact factor: 4.398

5.  Teriparatide increases bone formation and bone mineral density in adult women with anorexia nervosa.

Authors:  Pouneh K Fazeli; Irene S Wang; Karen K Miller; David B Herzog; Madhusmita Misra; Hang Lee; Joel S Finkelstein; Mary L Bouxsein; Anne Klibanski
Journal:  J Clin Endocrinol Metab       Date:  2014-01-23       Impact factor: 5.958

6.  Changes in femur neck bone density in US adults between 1988-1994 and 2005-2008: demographic patterns and possible determinants.

Authors:  A C Looker; L J Melton; L G Borrud; J A Shepherd
Journal:  Osteoporos Int       Date:  2011-04-06       Impact factor: 4.507

7.  Determinants of skeletal loss and recovery in anorexia nervosa.

Authors:  Karen K Miller; Ellen E Lee; Elizabeth A Lawson; Madhusmita Misra; Jennifer Minihan; Steven K Grinspoon; Suzanne Gleysteen; Diane Mickley; David Herzog; Anne Klibanski
Journal:  J Clin Endocrinol Metab       Date:  2006-05-30       Impact factor: 5.958

8.  Estradiol levels predict bone mineral density in male collegiate athletes: a pilot study.

Authors:  Kathryn E Ackerman; Gary S Skrinar; Eva Medvedova; Madhusmita Misra; Karen K Miller
Journal:  Clin Endocrinol (Oxf)       Date:  2012-03       Impact factor: 3.478

9.  Body composition predictors of skeletal integrity in obesity.

Authors:  Melanie Schorr; Laura E Dichtel; Anu V Gerweck; Martin Torriani; Karen K Miller; Miriam A Bredella
Journal:  Skeletal Radiol       Date:  2016-03-16       Impact factor: 2.199

10.  Bone mineral density in patients with early rheumatoid arthritis treated with corticosteroids.

Authors:  George S Habib; Shehadeh Haj
Journal:  Clin Rheumatol       Date:  2004-09-14       Impact factor: 2.980

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.