The effect of room temperature on dual-energy X-ray absorptiometry.

N L Culton1, N A Pocock.   

Abstract

There has been little published data on the effects of temperature on the performance of dual-energy X-ray absorptiometry (DXA) machines. We examined the effect of changes in ambient room temperature on the performance of three DXA scanners (DPXL, Expert-XL and Prodigy). The study involved repeat measurements of bone mineral density (BMD) using three different spine phantoms scanned at different ambient room temperatures, both before and after calibration procedures. The calibration or quality assurance (QA) scan calibrates the scanner, adjusting for the ambient room temperature at the time of calibration. There was a moderate correlation between change in temperature and change in BMD measured prior to recalibration for the Expert-XL ( r=0.58) during normal clinical scanning conditions. There was no observed change in phantom BMD with change in temperature measured using the DXPL or Prodigy. After temperature change, without repeat calibration measurements, there was a strong correlation between temperature change and change in BMD measured using the Expert-XL ( r=0.96, p<0.001). From the regression equation, a change of 2.5 degrees C could alter the calculated BMD result measured by the Expert-XL by 1.5%, which would significantly affect the precision of the DXA system. There was no significant correlation between temperature and BMD in the DXPL or Prodigy. The observed differences between the densitometers and the effect of temperature change are most likely due to the differing types of detector systems used. Operators must be made aware that solid state detectors of the sort used in the Expert-XL (charge-coupled devices, CCDs) are significantly affected by changes in ambient room temperature.

Mesh:

Year:  2003        PMID: 12730777     DOI: 10.1007/s00198-002-1330-y

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  4 in total

1.  Image resolution of the Lunar Expert-XL.

Authors:  J A Thorpe; S A Steel
Journal:  Osteoporos Int       Date:  1999       Impact factor: 4.507

2.  Axial and total-body bone densitometry using a narrow-angle fan-beam.

Authors:  R B Mazess; J A Hanson; R Payne; R Nord; M Wilson
Journal:  Osteoporos Int       Date:  2000       Impact factor: 4.507

3.  A preliminary evaluation of the lunar expert-XL for bone densitometry and vertebral morphometry.

Authors:  T Lang; M Takada; R Gee; C Wu; J Li; C Hayashi-Clark; S Schoen; V March; H K Genant
Journal:  J Bone Miner Res       Date:  1997-01       Impact factor: 6.741

4.  Comparison of two Hologic DXA systems (QDR 1000 and QDR 4500/A).

Authors:  N Barthe; P Braillon; D Ducassou; B Basse-Cathalinat
Journal:  Br J Radiol       Date:  1997-07       Impact factor: 3.039

  4 in total
  1 in total

1.  Temperature influence on DXA measurements: bone mineral density acquisition in frozen and thawed human femora.

Authors:  Dirk Wähnert; Konrad L Hoffmeier; Gabriele Lehmann; Rosemarie Fröber; Gunther O Hofmann; Thomas Mückley
Journal:  BMC Musculoskelet Disord       Date:  2009-02-24       Impact factor: 2.362

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.