Literature DB >> 9234878

Hydroxyapatite-coated total hip femoral components in patients less than fifty years old. Clinical and radiographic results after five to eight years of follow-up.

W N Capello1, J A D'Antonio, J R Feinberg, M T Manley.   

Abstract

One hundred and thirty-three patients (152 hips) who were an average of thirty-nine years old (range, sixteen to forty-nine years old) received a proximally hydroxyapatite-coated femoral prosthesis as part of a total hip arthroplasty and were followed for a minimum of five years (average, 6.4 years; range, five to 8.3 years) or until revision. The average Harris hip score was 47 points (range, 22 to 77 points) preoperatively and 93 points (range, 49 to 100 points) at the time of the latest clinical evaluation. Two patients who had a well fixed femoral implant had activity-limiting pain in the thigh at the time of the most recent examination. Radiographic changes consistent with bone-remodeling (cortical hypertrophy and bone condensation) typically were seen around the mid-part of the shaft of the prosthesis. Forty-eight (32 per cent) of the 148 hips that were included in the radiographic analysis demonstrated a small amount of erosive scalloping in either zone 1 or zone 7 of Gruen et al., and intramedullary osteolysis was suspected in only one hip. All stems were radiographically osseointegrated according to a modification of the criteria described by Engh et al. Four stems were revised, but none of the revisions were performed because of mechanical failure (two stems were revised in conjunction with a revision of the cup because of pain; one, because of an infection; and one, after a traumatic femoral fracture that occurred six years postoperatively). Thus, the rates of aseptic and mechanical failure were both 0 per cent. The combined rate of failure, which included the two stems that were revised because of pain and the two stems that were associated with pain that limited activity, was 2.6 per cent (four of 152 stems). The over-all clinical results associated with hydroxyapatite-coated femoral components were excellent in this group of young patients after intermediate-term follow-up. A review of serial radiographs showed mechanically stable implants with osseous ingrowth, evidence of stress transmission at the middle part of the stem, and minimum endosteal osteolysis.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9234878     DOI: 10.2106/00004623-199707000-00008

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  11 in total

1.  Comparison of wear and osteolysis in hip replacement using two different coatings of the femoral stem.

Authors:  Joaquin Sanchez-Sotelo; David G Lewallen; William Scott Harmsen; Jeffrey Harrington; Miguel E Cabanela
Journal:  Int Orthop       Date:  2004-04-29       Impact factor: 3.075

2.  Current attitudes to total hip replacement in the younger patient: results of a national survey.

Authors:  T D Tennent; N J Goddard
Journal:  Ann R Coll Surg Engl       Date:  2000-01       Impact factor: 1.891

3.  Microstructural analysis of implant-bone interface of hydroxyapatite-coated and uncoated Schanz screws.

Authors:  M Cimerman; A Cör; M Ceh; A Kristan; J Pizem; M Tonin
Journal:  J Mater Sci Mater Med       Date:  2005-07       Impact factor: 3.896

4.  Custom cementless stem improves hip function in young patients at 15-year followup.

Authors:  Xavier Flecher; Oliver Pearce; Sebastien Parratte; Jean-Manuel Aubaniac; Jean-Noel Argenson
Journal:  Clin Orthop Relat Res       Date:  2009-08-19       Impact factor: 4.176

5.  Fortifying the Bone-Implant Interface Part 1: An In Vitro Evaluation of 3D-Printed and TPS Porous Surfaces.

Authors:  Regina F MacBarb; Derek P Lindsey; Chelsea S Bahney; Shane A Woods; Mark L Wolfe; Scott A Yerby
Journal:  Int J Spine Surg       Date:  2017-06-01

6.  Calcium orthophosphate coatings, films and layers.

Authors:  Sergey V Dorozhkin
Journal:  Prog Biomater       Date:  2012-09-26

7.  Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50 years old: results after 12-years follow-up.

Authors:  Cesare Faldini; Maria Teresa Miscione; Mohammadreza Chehrassan; Francesco Acri; Camilla Pungetti; Michele d'Amato; Deianira Luciani; Sandro Giannini
Journal:  J Orthop Traumatol       Date:  2011-11-24

8.  High 10-year survival rate with an anatomic cementless stem (SPS).

Authors:  Elhadi Sariali; Alexandre Mouttet; Philippe Mordasini; Yves Catonné
Journal:  Clin Orthop Relat Res       Date:  2012-03-09       Impact factor: 4.176

9.  Calcium orthophosphates as bioceramics: state of the art.

Authors:  Sergey V Dorozhkin
Journal:  J Funct Biomater       Date:  2010-11-30

10.  Failure of dual radius hydroxyapatite-coated acetabular cups.

Authors:  Fabio D'Angelo; Mauro Molina; Giacomo Riva; Giovanni Zatti; Paolo Cherubino
Journal:  J Orthop Surg Res       Date:  2008-08-07       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.