Literature DB >> 920115

Metal sensitivity in patients treated for tibial fractures with plates of stainless steel.

M Cramers, U Lucht.   

Abstract

In three patients a local dermatitis developed 3-3 1/2 months after tibial osteosynthesis with plates and screws of stainless steel 316 L (AO). Two of the patients had a positive patch test for chromium (and cobalt) and one for nickel. Infection was not indicated and it is suggested that the dermatitis was caused by a metallic sensitivity. The skin affection disappeared after removal of the metal.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 920115     DOI: 10.3109/17453677708988763

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  26 in total

1.  In vitro corrosion behaviour of Ti-Nb-Sn shape memory alloys in Ringer's physiological solution.

Authors:  F Rosalbino; D Macciò; G Scavino; A Saccone
Journal:  J Mater Sci Mater Med       Date:  2012-02-05       Impact factor: 3.896

2.  Factors to consider in joint prosthesis systems.

Authors:  Larry M Wolford
Journal:  Proc (Bayl Univ Med Cent)       Date:  2006-07

3.  In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation.

Authors:  Nadim James Hallab; Marco Caicedo; Rachel Epstein; Kyron McAllister; Joshua J Jacobs
Journal:  J Biomed Mater Res A       Date:  2010-02       Impact factor: 4.396

4.  [New therapeutic possibilities in orthodontics in patients with nickel allergy].

Authors:  J Bachmann
Journal:  Fortschr Kieferorthop       Date:  1987-12

5.  [Metallurgical differentiation of cobalt-chromium alloys for implants].

Authors:  U Holzwarth; P Thomas; W Kachler; J Göske; A Schuh
Journal:  Orthopade       Date:  2005-10       Impact factor: 1.087

6.  [Pathological findings in tissue surrounding revised metal/metal articulations].

Authors:  W Baur; W Hönle; H-G Willert; A Schuh
Journal:  Orthopade       Date:  2005-03       Impact factor: 1.087

7.  [Implant allergies].

Authors:  P Thomas; M Thomsen
Journal:  Hautarzt       Date:  2010-03       Impact factor: 0.751

Review 8.  [Titanium or steel as osteosynthesis material : Systematic literature search for clinical evidence].

Authors:  Alexander Joeris; Sabine Goldhahn; Elke Rometsch; Dankward Höntzsch
Journal:  Unfallchirurg       Date:  2017-02       Impact factor: 1.000

9.  [Allergy to metal following osteosynthesis].

Authors:  S Hierholzer; G Hierholzer
Journal:  Unfallchirurgie       Date:  1982-12

10.  [Orthopedic surgical implants and allergies: joint statement by the implant allergy working group (AK 20) of the DGOOC (German association of orthopedics and orthopedic surgery), DKG (German contact dermatitis research group) and dgaki (German society for allergology and clinical immunology)].

Authors:  P Thomas; A Schuh; J Ring; M Thomsen
Journal:  Orthopade       Date:  2008-01       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.