Literature DB >> 2661750

Prone versus supine thallium myocardial SPECT: a method to decrease artifactual inferior wall defects.

G M Segall1, M J Davis.   

Abstract

Artifactual inferior wall defects as a result of diaphragmatic attenuation of activity are a frequent source of error in thallium myocardial single photon emission computed tomography (SPECT) studies. Thirty-four patients and 11 clinically normal volunteers were studied prospectively to see if specificity of inferior wall defects for right coronary artery disease could be improved by scanning patients prone versus supine. All individuals were scanned both prone and supine, in random order, following symptom limited treadmill exercise. Images were acquired at 3 degrees steps, 25 sec per frame, in a 180 degrees elliptical orbit always beginning in the 45 degrees right anterior oblique position relative to the patient. Polar maps generated from the short axis slices were used to calculate the average regional activity. The prone studies showed consistently higher inferior wall activity compared to the supine studies on both the exercise (182 +/- 22 vs. 160 +/- 23, p less than or equal to 0.001) and 4-hr delay studies (183 +/- 20 vs. 175 +/- 21, p less than or equal to 0.001). Prone imaging resulted in a significantly higher specificity for RCA disease compared to supine imaging (90% vs. 66%, p less than 0.05) with an improvement in accuracy from 71% to 82%. Sensitivity, specificity, and accuracy for left anterior descending and left circumflex artery disease were not significantly affected by patient position during imaging. All patients having SPECT thallium myocardial perfusion studies should be imaged prone to minimize artifactual inferior wall defects and improve accuracy.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2661750

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  36 in total

1.  The higher likelihood of developing cardiomegaly during follow-up in patients with syndrome X and abnormal thallium-201 myocardial perfusion SPECT.

Authors:  S S Sun; J L Huang; S C Tsai; Y J Ho; C H Kao
Journal:  Int J Cardiovasc Imaging       Date:  2001-08       Impact factor: 2.357

2.  Procedure guidelines for radionuclide myocardial perfusion imaging.

Authors:  C Anagnostopoulos; M Harbinson; A Kelion; K Kundley; C Y Loong; A Notghi; E Reyes; W Tindale; S R Underwood
Journal:  Heart       Date:  2004-01       Impact factor: 5.994

3.  Supine-prone SPECT myocardial perfusion imaging: the poor man's attenuation compensation.

Authors:  Stephen A Stowers; Richard Umfrid
Journal:  J Nucl Cardiol       Date:  2003 May-Jun       Impact factor: 5.952

4.  Single photon-emission computed tomography.

Authors:  Thomas A Holly; Brian G Abbott; Mouaz Al-Mallah; Dennis A Calnon; Mylan C Cohen; Frank P DiFilippo; Edward P Ficaro; Michael R Freeman; Robert C Hendel; Diwakar Jain; Scott M Leonard; Kenneth J Nichols; Donna M Polk; Prem Soman
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

5.  Combined supine and prone imaging acquisition in cardiac SPECT: A turn for the better.

Authors:  Mylan C Cohen
Journal:  J Nucl Cardiol       Date:  2016-01-07       Impact factor: 5.952

6.  EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology.

Authors:  B Hesse; K Tägil; A Cuocolo; C Anagnostopoulos; M Bardiés; J Bax; F Bengel; E Busemann Sokole; G Davies; M Dondi; L Edenbrandt; P Franken; A Kjaer; J Knuuti; M Lassmann; M Ljungberg; C Marcassa; P Y Marie; F McKiddie; M O'Connor; E Prvulovich; R Underwood; B van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07       Impact factor: 9.236

7.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

8.  One size fits all?

Authors:  Robert C Hendel
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

9.  Diagnostic accuracy of gated Tc-99m sestamibi stress myocardial perfusion SPECT with combined supine and prone acquisitions to detect coronary artery disease in obese and nonobese patients.

Authors:  Daniel S Berman; Xingping Kang; Hidetaka Nishina; Piotr J Slomka; Leslee J Shaw; Sean W Hayes; Ishac Cohen; John D Friedman; James Gerlach; Guido Germano
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

10.  Two-position supine/prone myocardial perfusion SPECT (MPS) imaging improves visual inter-observer correlation and agreement.

Authors:  Reza Arsanjani; Sean W Hayes; Mathews Fish; Aryeh Shalev; Rine Nakanishi; Louise E J Thomson; John D Friedman; Guido Germano; Daniel S Berman; Piotr Slomka
Journal:  J Nucl Cardiol       Date:  2014-05-08       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.