Literature DB >> 9178109

Marginal bone level buccal to mandibular molars in digital radiographs from charge-coupled device and storage phosphor systems. An in vitro study.

E Borg1, K Gröndahl, H G Gröndahl.   

Abstract

The aim of this in vitro study was to compare bone loss measurements in the furcation area of mandibular molars in digital radiographs from a CCD-(Sens-A-Ray) and a storage phosphor (Digora) system, 10 1st and 7 2nd mandibular molars, with intact lingual but reduced buccal bone with furcation involvements, were used. Radiographs were first taken with lead markers at the most apical part of the buccal bone and at the cemento-enamel junction. These radiographs were used to establish a radiographically true distance between the CEJ and the buccal bone level. The lead marker at the CEJ served as a reference point for the observers' subsequent estimates of the extent of bone removed, which were made in radiographs without lead markers at the bone level. 1 exposure (400 ms) for the CCD- and 5 (160 ms, 200 ms, 250 ms, 320 ms, 400 ms) for the storage phosphor system were used. Measurements were made in unprocessed (original) and processed images (contrast enhanced and/or high pass filtered). The results showed underestimation of bone loss, but smaller than previously reported for film radiographs. No significant difference was found between the 2 systems when compared at the same exposure. Nor were any significant differences found between unprocessed and processed images or between storage phosphor images from different exposures. We conclude that digital radiographs are comparable to film based radiographs for measurement of buccal bone loss but that lower exposures can be used, especially with the storage phosphor system.

Entities:  

Mesh:

Year:  1997        PMID: 9178109     DOI: 10.1111/j.1600-051x.1997.tb00762.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  8 in total

1.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 1: the influence of X-ray generator on periodontal measurements using conventional and digital receptors.

Authors:  Bart Vandenberghe; Livia Corpas; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-05       Impact factor: 3.573

2.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 2: the influence of intra-oral image receptor on periodontal measurements.

Authors:  Bart Vandenberghe; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-12       Impact factor: 3.573

3.  Measurement accuracy and perceived quality of imaging systems for the evaluation of periodontal structures.

Authors:  B Güniz Baksi
Journal:  Odontology       Date:  2008-07-27       Impact factor: 2.634

4.  The usage of digital radiography and cone beam computed tomography among Turkish dentists.

Authors:  Semanur Dölekoğlu; E Fişekçioğlu; M İlgüy; D İlgüy
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

5.  Radiopacity of dental restorative materials.

Authors:  Tomaž Hitij; Aleš Fidler
Journal:  Clin Oral Investig       Date:  2012-07-24       Impact factor: 3.573

6.  Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study.

Authors:  Rafael Scaf de Molon; Juliana Aparecida Najarro Dearo Morais-Camillo; Celso Eduardo Sakakura; Mauricio Goncalves Ferreira; Leonor Castro Monteiro Loffredo; Gulnara Scaf
Journal:  Imaging Sci Dent       Date:  2012-12-23

7.  Comparison between inverted and unprocessed digitized radiographic imaging in periodontal bone loss measurements.

Authors:  Gulnara Scaf; Olívia Morihisa; Leonor de Castro Monteiro Loffredo
Journal:  J Appl Oral Sci       Date:  2007-12       Impact factor: 2.698

8.  The influence of tube potential on periodontal bone level measurements and subjective image quality using a digital photostimulable storage phosphor sensor.

Authors:  Bart Vandenberghe; Reinhilde Jacobs
Journal:  J Oral Maxillofac Res       Date:  2010-04-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.