Literature DB >> 9170041

Optimization of contrast timing for breath-hold three-dimensional MR angiography.

T F Hany1, G C McKinnon, D A Leung, T Pfammatter, J F Debatin.   

Abstract

The purpose of this study was to determine the influence of various factors (age, weight, breathing, saline flush) on the contrast kinetics of a test bolus injection for the purpose of calculating the scan delay for optimized contrast-enhanced three-dimensional MR angiography. Initially, the test bolus administration was optimized by evaluating the influence of breathing (breathing versus breath-hold) and the administration of a saline flush after the contrast injection (no flush versus flush) on the kinetics of a 4-ml Gd-DTPA test bolus injection in three healthy volunteers. Subsequently, in 33 patients referred for three-dimensional MR angiography of the renal arteries, test bolus kinetics were correlated to age, weight, and heart rate. In addition, the image quality of the three-dimensional MR angiograms was assessed on a four-point scale with regard to vessel visibility. The administration of a saline flush after the contrast injection significantly shortened the first appearance time (14 versus 16 seconds, P < .05), as well as the time to maximal signal intensity (SI) (6 versus 10 seconds, P < .05) and increased both maximum (67 versus 151 seconds, P < .05) and the SI slope (6.4 versus 20.5 seconds, P < .05). Breath-holding was shown to have no significant affect on the test bolus kinetics. No correlation was found between physiologic parameters and test bolus kinetics in the patient group. Image quality was graded as sufficient for diagnostic purposes in 32 of 33 patients. The contrast travel time from injection site to the vascular system under consideration cannot be predicted based on physiologic parameters. This time interval can be reliably and accurately determined by a test bolus injection of a small volume of contrast agent followed by a saline flush during normal breathing.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9170041     DOI: 10.1002/jmri.1880070316

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  12 in total

1.  Gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries with multiple bolus injection: scan optimization in vitro and in vivo.

Authors:  J J Westenberg; M N Wasser; R J van der Geest; P M Pattynama; A de Roos; J Vanderschoot; J H Reiber
Journal:  Int J Card Imaging       Date:  1999-04

2.  3D contrast-enhanced MR angiography using fluoroscopic triggering and an elliptical centric view order.

Authors:  S J Riederer; S B Fain; D G Kruger; R F Busse
Journal:  Int J Card Imaging       Date:  1999-04

3.  Contrast enhanced body magnetic resonance angiography.

Authors:  A E Stillman
Journal:  Int J Card Imaging       Date:  1999-04

4.  Real-time imaging and triggering of 3D contrast-enhanced MR angiograms using MR fluoroscopy.

Authors:  S J Riederer; S B Fain; D G Kruger; R F Busse
Journal:  MAGMA       Date:  1999-08       Impact factor: 2.310

5.  Time-resolved magnetic resonance angiography: evaluation of intrapulmonary circulation parameters in pulmonary arterial hypertension.

Authors:  Hyun J Jeong; Parmede Vakil; John J Sheehan; Sanjiv J Shah; Michael Cuttica; James C Carr; Timothy J Carroll; Amir Davarpanah
Journal:  J Magn Reson Imaging       Date:  2011-01       Impact factor: 4.813

Review 6.  Cross-sectional vascular imaging with CT and MR angiography.

Authors:  Hasan K Kabul; Klaus D Hagspiel
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

7.  Contrast-kinetics-resolved whole-heart coronary MRA using 3DPR.

Authors:  Peng Lai; Feng Huang; Yu Li; Sonia Nielles-Vallespin; Xiaoming Bi; Renate Jerecic; Debiao Li
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

8.  Crossover comparison of ferumoxytol and gadobenate dimeglumine for abdominal MR-angiography at 3.0 tesla: Effects of contrast bolus length and flip angle.

Authors:  Tilman Schubert; Utaroh Motosugi; Sonja Kinner; Timothy J Colgan; Samir D Sharma; Scott Hetzel; Shane Wells; Camilo A Campo; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2016-11-10       Impact factor: 4.813

9.  Use of cardiac output to improve measurement of input function in quantitative dynamic contrast-enhanced MRI.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Qun Chen; Pippa Storey; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

10.  Three-dimensional contrast-enhanced magnetic-resonance angiography of the renal arteries: interindividual comparison of 0.2 mmol/kg gadobutrol at 1.5 T and 0.1 mmol/kg gadobenate dimeglumine at 3.0 T.

Authors:  Ulrike I Attenberger; Henrik J Michaely; Bernd J Wintersperger; Steven P Sourbron; Klaus-Peter Lodemann; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2008-02-16       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.