Literature DB >> 9151173

Influence of implant diameters on the integration of screw implants. An experimental study in rabbits.

C J Ivanoff1, L Sennerby, C Johansson, B Rangert, U Lekholm.   

Abstract

The influence of diameter on the integration of titanium screw-shaped implants was studied in the rabbit tibia by means of removal torque measurements and histomorphometry. Implants 3.0, 3.75, 5.0, and 6.0 mm in diameter and 6.0 mm long were inserted through one cortical layer in the tibial metaphyses of nine rabbits and allowed to heal for 12 weeks. The implants were then unscrewed with a torque gauge, and the peak torque required to shear off the implants was recorded. The histologic analysis in undemineralized ground sections comprised (1) a gross description of the implant sites and assessments of (2) the total implant length in bone and (3) in the cortical passage, as well as (4) the thickness of the cortical bone adjacent to the implants. From the removal torque values obtained and morphometric measurements, a mean shear stress value was calculated for each implant type. The biomechanical tests showed a statistically significant increase of removal torque with increasing implant diameter. The resistance to shear seemed to be determined by the implant surface in supportive cortical bone, whereas the newly formed bone at the periosteal and endosteal surfaces did not seem to have any supportive properties after 12 weeks. It is suggested that wide diameter implants may be used clinically to increase implant stability.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9151173     DOI: 10.1016/s0901-5027(05)80837-9

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  21 in total

1.  Measurement for natural dental neck data of normal adults and its clinical significance on guiding implant restoration.

Authors:  Mingxu Sun; Fang Gu; Junjun Wang; Chengyuan Zhou; Junnan Xia; Hongwei Qin; Jianjun Yang
Journal:  Int J Clin Exp Med       Date:  2015-09-15

2.  Photoelastic stress analysis in prosthetic implants of different diameters: mini, narrow, standard or wide.

Authors:  Marcelo Coelho Goiato; Alves Aldiéris Pesqueira; Daniela Micheline Dos Santos; Marcela Filié Haddad; Amália Moreno
Journal:  J Clin Diagn Res       Date:  2014-09-20

3.  Posterior partially edentulous jaws, planning a rehabilitation with dental implants.

Authors:  Douglas R Monteiro; Emily V F Silva; Eduardo P Pellizzer; Osvaldo Magro Filho; Marcelo C Goiato
Journal:  World J Clin Cases       Date:  2015-01-16       Impact factor: 1.337

Review 4.  Implant surface characteristics and their effect on osseointegration.

Authors:  A Barfeie; J Wilson; J Rees
Journal:  Br Dent J       Date:  2015-03-13       Impact factor: 1.626

5.  A pilot study of mini implants as a treatment option for prosthetic rehabilitation of ridges with sub-optimal bone volume.

Authors:  Anitha Balaji; Jumshad B Mohamed; R Kathiresan
Journal:  J Maxillofac Oral Surg       Date:  2011-02-25

6.  Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year.

Authors:  Renzo Guarnieri; Dario Di Nardo; Gianni Di Giorgio; Gabriele Miccoli; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2020-04-01

7.  [Clinical and radiological results after augmentation procedures - a prospective study].

Authors:  Karl Andreas Schlegel; Tarek Karascholi; Matthias Fenner; Emeka Nkenke
Journal:  Mund Kiefer Gesichtschir       Date:  2007-07-20

8.  Developing a new dental implant design and comparing its biomechanical features with four designs.

Authors:  Mansour Rismanchian; Reza Birang; Mahdi Shahmoradi; Hassan Talebi; Reza Jabar Zare
Journal:  Dent Res J (Isfahan)       Date:  2010

9.  Evaluation of Micromovements and Stresses around Single Wide-Diameter and Double Implants for Replacing Mandibular Molar: A Three-Dimensional FEA.

Authors:  Shrikar R Desai; I Karthikeyan; Rika Singh
Journal:  ISRN Dent       Date:  2012-03-07

10.  3D finite element analysis of immediate loading of single wide versus double implants for replacing mandibular molar.

Authors:  Shrikar R Desai; I Karthikeyan; Reetika Gaddale
Journal:  J Indian Soc Periodontol       Date:  2013-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.