Effects of pulsed ultrasound on the frog heart: III. The radiation force mechanism.

D Dalecki1, C H Raeman, S Z Child, E L Carstensen.   

Abstract

Earlier studies have shown that a single, millisecond duration pulse of ultrasound delivered to the frog heart in vivo during systole can produce a reduction in the developed aortic pressure, while a pulse delivered during diastole can produce a premature ventricular contraction. The threshold for these effects is 5-10 MPa with a 5-ms pulse. Since cardiac tissues respond to mechanical stimulation, the objective of this study was to investigate acoustic radiation force as a possible mechanism for the observed effects of ultrasound on the frog heart. In two experiments, the radiation force exerted on the heart was varied by varying the ultrasonic frequency and the acoustic beam width. Results of these studies indicated that the rate of occurrence of the reduced aortic pressure effect was directly correlated with the magnitude of the radiation force exerted on the heart. A third experiment tested the radiation force mechanism directly by placing an acoustic reflector on the frog heart. The acoustic reflector maximized the radiation force delivered to the heart, but eliminated direct interaction of the ultrasound with the heart and experimentally eliminated heating and cavitation as mechanisms of action. The reduced aortic pressure effect was observed with the reflector on the heart, indicating that radiation force is capable of producing this effect. No premature ventricular contractions were observed with the acoustic reflector over the heart, suggesting that another property of the exposure may be responsible for this bioeffect.

Mesh:

Year:  1997        PMID: 9140184     DOI: 10.1016/s0301-5629(96)00209-8

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  14 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 5.  Ultrasound-biophysics mechanisms.

Authors:  William D O'Brien
Journal:  Prog Biophys Mol Biol       Date:  2006-08-08       Impact factor: 3.667

6.  Activation of Piezo1 but Not NaV1.2 Channels by Ultrasound at 43 MHz.

Authors:  Martin Loynaz Prieto; Kamyar Firouzi; Butrus T Khuri-Yakub; Merritt Maduke
Journal:  Ultrasound Med Biol       Date:  2018-03-07       Impact factor: 2.998

7.  Are ECG premature complexes induced by ultrasonic cavitation electrophysiological responses to irreversible cardiomyocyte injury?

Authors:  Douglas L Miller; Chunyan Dou; Benedict R Lucchesi
Journal:  Ultrasound Med Biol       Date:  2011-02       Impact factor: 2.998

Review 8.  Conditionally Increased Acoustic Pressures in Nonfetal Diagnostic Ultrasound Examinations Without Contrast Agents: A Preliminary Assessment.

Authors:  Kathryn R Nightingale; Charles C Church; Gerald Harris; Keith A Wear; Michael R Bailey; Paul L Carson; Hui Jiang; Kurt L Sandstrom; Thomas L Szabo; Marvin C Ziskin
Journal:  J Ultrasound Med       Date:  2015-07       Impact factor: 2.153

9.  Transthoracic cardiac ultrasonic stimulation induces a negative chronotropic effect.

Authors:  Elaine B Buiochi; Rita J Miller; Emily Hartman; Flavio Buiochi; Rosana A Bassani; Eduardo T Costa; William D O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-12       Impact factor: 2.725

Review 10.  Ultrasound mediated delivery of drugs and genes to solid tumors.

Authors:  Victor Frenkel
Journal:  Adv Drug Deliv Rev       Date:  2008-04-03       Impact factor: 15.470