Literature DB >> 9134105

Twitch interpolation in the assessment of the maximum force-generating capacity of the jaw-closing muscles in man.

M F Lyons1, S W Cadden, R H Baxendale, R Yemm.   

Abstract

The method of twitch interpolation was employed to study the maximum potential bite forces of humans. Transcutaneous electrical stimuli were applied to parts of one or both masseter muscles in eight volunteers while they bit with a variable but controlled isometric force on a unidirectional force transducer held between the anterior teeth. In all participants the twitch force produced by a single 1-ms pulse, of 25 50 mA intensity, was inversely and linearly related to the voluntary bite force. For each participant the slope of the regression between twitch force and bite force depended on the stimulus intensity and not on whether the stimulus was applied to one or both masseters. Extrapolation of the regression lines to zero twitch force showed that they converged towards a bite-force value that, for any given participant varied only a small amount between different stimulus intensities. For most participants this bite force lay above the maximum that they produced voluntarily: voluntary maximum bites ranged from 153 to 593 N, while the extrapolations predicted a narrower and higher potential range of 282-629 N. It was concluded that, for the masseters at least, there is often spare force-generating capacity which individuals are either unable or not prepared to utilize. This method is non-invasive and may help to define better the maximum bite-force potential of humans.

Entities:  

Mesh:

Year:  1996        PMID: 9134105     DOI: 10.1016/s0003-9969(96)00086-6

Source DB:  PubMed          Journal:  Arch Oral Biol        ISSN: 0003-9969            Impact factor:   2.633


  7 in total

1.  Measurement of voluntary activation of fresh and fatigued human muscles using transcranial magnetic stimulation.

Authors:  Gabrielle Todd; Janet L Taylor; S C Gandevia
Journal:  J Physiol       Date:  2003-08-08       Impact factor: 5.182

Review 2.  Assessing voluntary muscle activation with the twitch interpolation technique.

Authors:  Anthony Shield; Shi Zhou
Journal:  Sports Med       Date:  2004       Impact factor: 11.136

3.  Fracture load of three-unit full-contour fixed dental prostheses fabricated with subtractive and additive CAD/CAM technology.

Authors:  Moritz Zimmermann; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2019-07-08       Impact factor: 3.573

4.  A simple safe, reliable and reproducible mechanism for producing experimental bite marks.

Authors:  S Subramanyeswara Chinni; Anas Al-Ibrahim; Andrew H Forgie
Journal:  J Forensic Odontostomatol       Date:  2013-12-01

Review 5.  Bite Force Recording Devices - A Review.

Authors:  Tarun Prakash Verma; Kanteshwari Iranagouda Kumathalli; Vinay Jain; Rajesh Kumar
Journal:  J Clin Diagn Res       Date:  2017-09-01

6.  Comparative evaluation of biting force and chewing efficiency of all-on-four treatment concept with other treatment modalities in completely edentulous individuals.

Authors:  Romesh Soni; Himanshi Yadav; Abhishek Pathak; Atul Bhatnagar; Vikram Kumar
Journal:  J Indian Prosthodont Soc       Date:  2020-07-17

7.  Determining a relationship between applied occlusal load and articulating paper mark area.

Authors:  Jason P Carey; Mark Craig; Robert B Kerstein; John Radke
Journal:  Open Dent J       Date:  2007-07-23
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.