Literature DB >> 33223702

Comparative evaluation of biting force and chewing efficiency of all-on-four treatment concept with other treatment modalities in completely edentulous individuals.

Romesh Soni1, Himanshi Yadav1, Abhishek Pathak2, Atul Bhatnagar1, Vikram Kumar1.   

Abstract

AIM: To compare and evaluate biting force and chewing efficiency of all-on-four treatment concept, implant-supported overdenture, and conventional complete denture. SETTINGS AND
DESIGN: Invivo - comparative study.
MATERIALS AND METHODS: A total of 12 edentulous patients were included in the study and conventional complete dentures were fabricated. Patients were divided into two groups. In Group 1, complete dentures were replaced with implant-supported overdenture, and in Group 2, complete dentures were replaced with hybrid denture supported by all-on-four treatment concept. The biting force was assessed using a bite force sensor and electromyographic recordings were made by electromyogram for masticatory muscles when chewing three different consistencies of foods. STATISTICAL ANALYSIS USED: The data was statistically analyzed using software SPSS version 22.0. Paired t-test was used for intra-group comparison and unpaired t-test was used for intergroup comparison.
RESULTS: The difference in biting force and chewing efficiency for all-on-four treatment concept was statistically significant for overdenture and complete denture. The highest biting force and chewing efficiency were observed for all-on-four treatment concept, followed by implant-supported overdenture and complete denture.
CONCLUSION: The study concluded that the completely edentulous individuals with atrophic posterior alveolar ridges can be rehabilitated successfully with improved biting force and chewing efficiency by All-on-four treatment concept. Copyright:
© 2020 The Journal of Indian Prosthodontic Society.

Entities:  

Keywords:  All-on-four treatment concept; biting force; chewing efficiency; complete denture; overdenture

Year:  2020        PMID: 33223702      PMCID: PMC7654204          DOI: 10.4103/jips.jips_464_19

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


INTRODUCTION

Tooth loss not only deteriorates oral function which includes mastication, swallowing, and speech but also adversely affects the self-esteem of individual by ruining esthetics.[1] Earlier complete denture was the only option available for rehabilitation of completely edentulous individuals, but over the period of time, treatment modalities have evolved. The rehabilitation of conventional complete denture wearers, no matter how perfectly done, could not completely solve their problems, either of functional and psychological. Complete denture wearer show a lower chewing efficiency in comparison to dentate controls.[2] The same functional impairment applies to maximum bite force, which was described to be 5–6 times lower than the dentate controls.[3] Complete denture wearers complained about the decreased retention, instability of prosthesis, decreased satisfaction, and reduced masticatory efficiency.[4] With the evolution in dental advancement techniques, introduction of dental implants, together has revolutionalized the prosthodontics field. It has improved the overall oral function and solved the problem of denture instability. It has provided various options for the treatment of edentulous individuals from removable prosthesis to fixed prosthesis including implant-supported overdenture and ceramometal or hybrid prosthesis, respectively. In highly resorbed ridges where adequate bone is available in the intraforaminal region of the mandible and in the premaxillary region of the maxilla, newer technique “All-on-Four” has been introduced by Malo et al.[56] This all-on-four treatment concept involves anteriorly placed two axially straight implants and posteriorly placed two tilted implants which are angled from 30° to 45° to retain a full-arch fixed prosthesis.[56] Every treatment modality has its own specific clinical indication with different prognostic results. The results are defined by the masticatory performance, chewing efficiency, patient's satisfaction, and improvement in quality of life.[78910] Various methods have been used to assess the efficiency of masticatory system, including the measurement of bite force and masticatory efficiency.[11] The results of some previous investigations showed a linear relationship between electromyographic activity potentials and direct bite force measurements.[12]

MATERIALS AND METHODS

This clinical study was undertaken in the Department of Prosthodontics, Crown and Bridge and Implantology, Faculty of Dental sciences, Varanasi, India. The approval for ethical clearance was obtained from the university ethical committee. ECR/Bhu/Inst/2013/Re-registeration-2017dt 31.01.2017. No. Dean/2018/EC/371.

Patient selection

A total of 12 patients were randomly selected, irrespective of gender, caste, religion, and creed for complete denture fabrication for the study following the inclusion and exclusion criteria. Six patients were selected in each group, where Group 1 included the patients with edentulous ridges and Group 2 included the edentulous patients with deficient bone in the posterior region. The adequate bone was present in the premaxilla region of the maxilla and the intraforaminal region of the mandible. In Group 1, edentulous patients were first rehabilitated with complete denture as baseline treatment, and after 1 month, bite force and electromyographic recordings were assessed and later complete dentures were replaced with implant-supported overdenture (2 implants are placed in the B and D region of the mandible, opposing complete denture in the maxillary arch). In Group 2, individuals were initially rehabilitated with conventional denture as baseline treatment, and after 1 month, bite force and electromyographic recordings were assessed and later complete dentures were replaced with all-on-four treatment. The average age of Group 1 was 55.83 years and Group 2 was 52.6 years.

Criteria for selection of cases

Inclusion criteria are shown in Table 1.
Table 1

Inclusion criteria

OverdentureAll-on-four
Completely edentulous patientCompletely edentulous patient
Absence of local infectionAbsence of local infection
Absence of oral mucosal diseaseAbsence of oral mucosal disease
Medical fitness for surgeryMedical fitness for surgery
Controlled diabetes, no systemic diseaseControlled diabetes, no systemic disease
Written consentWritten consent
Atrophic ridges posteriorly with adequate bone present in premaxillary region of maxilla and intraforaminal region of mandible
Inclusion criteria

Exclusion criteria

History of metabolic or systemic disease affecting the osseointegration Recent history of irradiation in the head and neck region Smokers Active infection, cyst, or tumor Psychiatric disorders or unrealistic expectations.

Methodology

Each patient was explained in detail and written informed consent was obtained. As a standard protocol, initially, all patients received conventional complete denture with bilateral balanced occlusion as prosthesis for evaluation of biting force and electromyographic records. In Group 1 individuals, implant placement was done with respect to canine region bilaterally in the mandibular arch and implant-supported overdenture was installed as final prosthesis [Figure 1]. The biting force was assessed using a bite force sensor (Bite Force Sensor, Hariom electronics, Vadodara, Gujarat, India) and masticatory muscle activity was measured using electromyogram. In Group 2, implant placement was done according to all-on-four treatment concept and hybrid denture as final definite prosthesis [Figure 2]. The biting force and electromyographic readings were recorded for final prosthesis, i.e., overdenture in Group 1 and hybrid denture in Group 2.
Figure 1

Orthopantomogram (overdenture)

Figure 2

Orthopantomogram (all-on-four)

Orthopantomogram (overdenture) Orthopantomogram (all-on-four) Biting force was measured using an electromechanical device which works on strain gauge-based Wheatstone bridge principle. The device consists of display unit and sensing probe [Figure 3]. The sensor is connected to the display unit which shows numerical values as a unit of measurement (Newton, KG or lb) set by the manufacturer. When sensing probes are placed between the occluding surfaces of dentition, deflections between the sensing probes of sensor give reading to the display unit which shows reading in mathematical units (Newton, Kg or lbs). The range of measurement of the device is 0–2500 Newton. The accuracy of bite force sensor used is ± 0.05% of its rated capacity.
Figure 3

Bite force measuring device

Bite force measuring device The chewing efficiency was measured by an electromyographic study. The electromyographic study was conducted on masseter, temporalis, and anterior digastric muscle bilaterally, i.e., right and left side. The individuals were given food in three different consistencies which included soft-consistency food, medium-consistency food, and hard-consistency food as banana, apple, and peanuts, respectively. This device consists of electromyography (EMG) device, three electrodes, and one display unit [Figure 4], and two electrodes are positioned on the skin of the concerned muscle. The third electrode is the reference electrode placed on the forehead. The display unit displays recordings in waveform.
Figure 4

Electromyographic presentation

Electromyographic presentation

Bite force measurement

The patient was asked to sit in the upright position with no headrest. Disposable sheet was wrapped on the sensing probes which were covered with 1-mm sponge sheet by double-sided adhesive tapes and the patient was instructed to bite right and left side thrice with maximum force at an interval of 2 min. Biting force was recorded by placing probes in between the occluding surfaces of maxillary and mandibular molars and the patient was asked to bite voluntarily with maximum force. The biting force was displayed in Newton on the display unit [Figure 5]. The biting force was recorded bilaterally, i.e., right side and left side separately. Three readings were recorded at an interval of 2 min and their average was calculated.
Figure 5

Bite force recording

Bite force recording

Electromyographic recordings

The EMG was recorded using computerized surface EMG (Synergy EMG-System, Arena medical care private limited, New Delhi, India). The patient was asked to sit in the upright position with no headrest. EMG recording was conducted in a calm and silent room. Electromyogram was used to perform surface electromyographic study of masseter, temporalis, and anterior digastric muscle. The patient's skin was wiped with 70% alcohol to reduce the impedance between the skin and the electrode. The electrode gel was applied on electrodes before placing on the skin and fixed there by using white tape. The three electrodes were used. The two electrodes were placed 2–3 mm away from each other along the muscle length. The surface electrodes were positioned in the direction of the fiber bundles of masseter, temporalis, and anterior digastric muscles. The third electrode was placed as the reference electrode on patient's forehead. The patient was given food materials: banana as soft-consistency food, apple as medium-consistency food, and peanuts as hard-consistency food. The recordings were made with right and left masseter, temporalis, and digastric muscles, respectively. The recordings were displayed on monitor in waveform. The maximum amplitude was calculated by counting peaks in microvolts [Figure 6].
Figure 6

Electromyographic recording

Electromyographic recording

Statistical analysis

All the data obtained were statistically analyzed using Statistical Package for the Social Sciences version 22.0. Intragroup comparison of biting force and chewing efficiency of masticatory muscles for the right and left side for Group 1 (complete denture and overdenture individuals) and Group 2 (complete denture and all-on-four individuals) was analyzed using paired t-test. Intergroup comparison of biting force and chewing efficiency of masticatory muscles for the right and left side between Group 1 (complete denture and overdenture individuals) and Group 2 (complete denture and all-on-four individuals) was analyzed using unpaired t-test.

RESULTS AND OBSERVATIONS

The biting force of hybrid denture supported by all-on-four treatment concept was significantly highest followed by overdenture and complete denture, respectively [Tables 2-4 and Graphs 1-3].
Table 2

Intragroup comparison of biting force within Group 1

SideProsthesisMean±SD (Newton)P
RightComplete denture25.00±14.180.001
Overdenture78.50±12.15
LeftComplete denture25.33±12.400.001
Overdenture82.00±23.97

SD: Standard deviation

Table 4

Intergroup comparison of biting force for Group 1 and Group 2

SideProsthesisMean±SD (Newton)P
RightOverdenture78.50±22.150.016
All-on-four219.16±117.35
LeftOverdenture82.00±23.970.005
All-on-four209.33±84.80

SD: Standard deviation

Graph 1

Intragroup comparison of biting force within Group 1

Graph 3

Intergroup comparison of biting force for Group 1 and Group 2

Intragroup comparison of biting force within Group 1 SD: Standard deviation Intragroup comparison of biting force within Group 2 SD: Standard deviation Intergroup comparison of biting force for Group 1 and Group 2 SD: Standard deviation Intragroup comparison of biting force within Group 1 Intragroup comparison of biting force within Group 2 Intergroup comparison of biting force for Group 1 and Group 2 The chewing efficiency was significantly highest for hybrid denture supported by all-on-four treatment concept followed by overdenture and complete denture, respectively [Tables 5-7 and Graphs 4-6]. The study has shown the highest chewing efficiency for masseter muscles compared to temporalis and digastric muscles. The higher chewing efficiency was observed in hard-consistency food as compared to medium- and soft-consistency food.
Table 5

Intragroup comparison of chewing efficiency for Group 1

Food consistencyProsthesisRight temporalisLeft temporalisRight masseterLeft masseterRight digastricLeft digastric






Mean±SD (μV)PMean±SD (μV)PMean±SD (μV)PMean±SD (μV)PMean±SD (μV)PMean±SD (μV)P
SoftComplete denture141.67±20.410.004116.67±25.810.005208.33±86.120.002225.00±75.820.007125.00±52.440.004158.33±49.150.027
Over denture225.00±27.38233.3±75.27383.33±25.81433.33±51.63250.00±54.77266.67±68.31
MediumComplete denture175.00±27.380.018166.67±40.820.003291.67±97.030.003241.67±58.450.001166.67±0.820.009183.33±60.550.014
Over denture275.00±61.23275.00±52.44441.67±37.63508.33±49.15283.33±75.27313.33±45.46
HardComplete denture233.33±25.810.001208.33±37.630.004358.33±111.430.012283.33±68.310.001200.00±54.770.010216.67±40.820.017
Over denture320.83±40.05333.33±51.63504.17±33.22575.00±52.44341.66±73.59333.33±60.55

SD: Standard deviation

Table 7

Intergroup comparison of chewing efficiency for Group 1 and Group 2

Food consistencyProsthesisRight temporalisLeft temporalisRight masseterLeft masseterRight digastricLeft digastric






Mean±SD (μV)PMean±SD (μV)PMean±SD (μV)PMean±SD (μV)PMean±SD (μV)PMean±SD (μV)P
SoftOverdenture225±27.380.001233.33±75.270.012383.33±25.810.030433.33±51.630.06250.00±54.770.021266.67±68.310.277
All-on-four325±27.38333.33±25.81604.17±212.37608.33±201.03350.00±70.71325.00±103.68
MediumOverdenture275.00±61.230.017275.0±52.440.014441.67±37.630.038508.33±49.150.114283.33±75.270.147313.33±45.460.091
All-on-four408.33±97.03379.16±67.85683.33±244.26666.67±218.32375.00±121.44408.33±115.83
HardOverdenture320.83±40.050.010333.33±51.630.019504.17±33.220.045575.00±52.440.051341.66±73.590.003333.33±60.550.003
All-on-four475.00±112.91458.33±97.09779.17±291.72808.33±251.82566.66±116.90558.33±124.16

SD: Standard deviation

Graph 4

Intragroup comparison of chewing efficiency for Group 1

Graph 6

Intergroup comparison of chewing efficiency for Group 1 and Group 2

Intragroup comparison of chewing efficiency for Group 1 SD: Standard deviation Intragroup comparison of chewing efficiency for Group 2 SD: Standard deviation Intergroup comparison of chewing efficiency for Group 1 and Group 2 SD: Standard deviation Intragroup comparison of chewing efficiency for Group 1 Intragroup comparison of chewing efficiency for Group 2 Intergroup comparison of chewing efficiency for Group 1 and Group 2

DISCUSSION

The present study was conducted to compare and evaluate bite force and chewing efficiency of all-on-four treatment with overdenture and complete denture. Extensive literature search revealed that no such study was conducted previously and this study is pioneer in comparing biting force and electromyographic activity of masticatory muscles among individuals rehabilitated with all-on-four treatment, implant-supported overdenture, and complete denture. Previous studies were conducted using different methods to record bite force and masticatory efficiency by measuring masticatory forces, duration required to pulverize given food, strokes used to pulverize given food, electrical activity of masticatory muscles, and size of particles after a given number of strokes. In the present study, electromyogram and bite force sensor were used to evaluate masticatory muscle activity and biting force, respectively. The various factors that influence bite force are age, craniofacial morphology, gender, periodontal support of teeth, signs and symptoms of temporomandibular disorders and pain, the tooth loss and type of restoration, malocclusion, total area of teeth in contact, oral motor function, and salivary glands function. In addition to these biological factors, the mechanical determinants including different recording devices, position of recording devices in dental arch, unilateral or bilateral measurements, using acrylic splints and opening wide of mouth etc also influences the biting force measurement.[13] The present study recorded bite force at molar and incisor regions thrice and their average was calculated to measure bite force. Although the accuracy of the bite force sensor used in the present study was 0.05%. The previous studies reported accuracy (10 N) and precision (80%) with strain gauge device which recorded a wide range of force (50–800 N).[14] According to Lyons et al., strain gauge transducers have been provided an accurate method for maximum bite force measurements, and recording is still difficult because biting on the hard metal surfaces of the transducers causes discomfort and fear of breaking of edges of teeth and restorations. Although the protective covers have decreased the discomfort and fear but has not been completely overcome the associated problem.[15] Various materials such as gauze, gutta percha, polyvinyl chloride, and acrylic resin have been used to cover the transducers.[16] In present study, the metal surface of sensing probes was covered using 2-mm sponge sheet by a double-sided adhesive tape which was further wrapped by disposable sheet to prevent fear of fracture of tooth edges. The overall sensor thickness was approximately 16 mm. Paphangkorakit and Osborn in their study revealed that an incisal separation 14–28 mm is most favorable opening for bite force measurement.[1718] The present study showed that the biting force was significantly higher for all-on-four concept than overdenture followed by complete denture. Previous studies reported that bite force increases in implant-supported overdenture than complete dentures and bite force is positively correlated to muscular activity.[192021] Carlsson and Lindquist conducted a study on 10 edentulous individuals initially rehabilitated with complete denture later replaced with fixed implant-retained prosthesis. The biting force has increased significantly from 80 N to 240 N.[22] van der Bilt et al. conducted a study to evaluate biting force and masticatory performance of complete denture and implant-supported mandibular overdenture, which has showed a statistically significant increased biting force from 116 N to 200 N for complete denture and overdenture, respectively.[23] The surface EMG records were made to evaluate the masticatory activity of masseter, temporalis, and anterior digastric muscles. Electromyogram is a biomedical device which capture signals by measuring electrical activity during muscle contraction. It is a tool to assess muscle activity. Few studies revealed that there is a linear relationship between EMG activity potentials and direct bite force measurements.[24] EMG is used to assess the electrical activity of specific muscle. Thus, EMG determines that how the muscles function during chewing and the role of specific muscle to the extent it performs in mastication (i.e., which muscle play what role to what extent). Our study showed a statistically significant difference in chewing efficiency in intragroup comparison of Group 1 (complete denture and implant-supported overdenture) and Group 2 (complete denture and hybrid denture supported by all-on-four treatment concept) individuals. The chewing efficiency of overdenture was significantly greater than conventional complete denture. Similarly, the chewing efficiency of hybrid denture was significantly greater than complete denture. In addition, intergroup comparison (overdenture and all-on-four) also showed a statistically significant difference in chewing efficiency with few exceptions. The chewing efficiency was highest in hybrid denture supported by all-on-four treatment concept, followed by implant-supported overdenture and complete denture for all three masticatory muscles when chewing different consistencies of foods. There was an insignificant difference observed in chewing efficiency of hybrid denture and overdenture in left masseter and right and left digastric muscles when chewing medium-consistency food and in left digastric muscle when chewing soft-consistency food. The current study showed a higher EMG activity of masseter muscles among other muscles. The present study showed higher EMG activity for hard-consistency food followed by medium- and soft-consistency food. However, Feine et al. in a cross-over study observed no statistically significant difference in patients' perception, electromyographic activity of overdenture, and implant-retained fixed prosthesis.[25262728] Ferrario et al. also showed similar results where they observed that overdentures and fixed implant-retained prosthesis were functionally equivalent. They conducted electromyographic study of masticatory muscles and concluded similar efficiency with implant-supported overdenture and fixed implant-supported prosthesis.[29] Apolinário et al. conducted a randomized controlled trial to evaluate masticatory function of complete denture and implant-supported dentures (fixed and overdenture).[30] Their study revealed a statistically significant difference for masticatory efficiency between conventional complete denture and implant-supported dentures (fixed and removable overdenture), but no significant difference was observed in masticatory efficiency of implant-supported overdenture and implant-retained fixed prosthesis.[30] Heydecke et al. conducted a crossover trial to show contrary results where they compared maxillary implant-retained fixed prosthesis with implant-supported overdentures opposed by mandibular implant-supported overdenture. The study revealed that removable overdenture has significantly higher chewing ability and general satisfaction than fixed prosthesis.[31] Previous studies revealed that EMG activity of masseter muscles was greater than the temporalis muscles. The masseter is considered as the strongest muscle, as it exerts higher pressure during mastication. Three different consistencies of food items were included in the study where banana as soft, apple without peel as medium, and peanut as hard-consistency food.[32] The limitations of the study includes small sample size, short-span study, random patient distribution among groups, and lack of advanced instruments for bite force measurement and masticatory muscle activity recordings. The study did not include individuals with full-mouth conventional implant fixed prosthesis. After eliminating the limitations of the current study, further researches and studies need to be conducted which are aimed for the enhancement of the quality of life of the edentulous individuals.

CONCLUSION

Within the limitations of the study, the present study conducted by us concludes that biting force and chewing efficiency improves with all-on-four treatment concept compared to implant-supported overdenture and conventional complete denture. The biting force and chewing efficiency were higher in all-on-four subjects followed by implant-supported overdenture and conventional complete denture. Among all three muscles, masseter muscle has showed higher electromyographic activity than temporalis and anterior digastric muscles. Among different consistencies of food, hard food has showed a higher electromyographic activity.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
Table 3

Intragroup comparison of biting force within Group 2

SideProsthesisMean±SD (Newton)P
RightComplete denture51.17±24.570.008
All-on-four219.17±117.35
LeftComplete denture55.67±28.660.002
All-on-four209.33±84.80

SD: Standard deviation

Table 6

Intragroup comparison of chewing efficiency for Group 2

Food consistencyProsthesisRight temporalisLeft temporalisRight masseterLeft masseterRight digastricLeft digastric






Mean±SD (μV)PMean±SD (μV)PMean±SD (μV)PMean±SD (μV)PMean±SD (μV)PMean±SD (μV)P
SoftComplete denture141.67±49.150.002116.67±40.820.001208.33±49.150.003191.67±73.500.004150.00±44.720.002133.33±51.630.005
All-on-four325.00±27.38333.33±25.81604.17±212.37608.33±201.03350.00±70.71325.00±103.68
MediumComplete denture208.33±20.410.001175.00±27.380.001266.67±93.090.011216.67±68.310.002158.33±20.410.004175.00±61.230.003
All-on-four408.33±97.03379.16±67.85683.33±244.26666.67±218.32375.00±121.44408.33±115.83
HardComplete denture241.67±20.410.004200.00±31.620.001308.33±106.840.016266.67±68.310.002175.00±41.830.001200.00±44.720.002
All-on-four475.00±112.91458.33±97.09779.17±291.72808.33±251.82566.67±116.90558.33±124.16

SD: Standard deviation

  28 in total

1.  Oral health status and treatment satisfaction with mandibular implant overdentures and conventional dentures: a randomized clinical trial in a senior population.

Authors:  Manal A Awad; James P Lund; Stanley H Shapiro; David Locker; Esa Klemetti; Antoine Chehade; Andre Savard; Jocelyne S Feine
Journal:  Int J Prosthodont       Date:  2003 Jul-Aug       Impact factor: 1.681

2.  Maximal bite forces in healthy young adults as predicted by surface electromyography.

Authors:  Virgilio F Ferrario; Chiarella Sforza; Gianfranco Zanotti; Gianluca M Tartaglia
Journal:  J Dent       Date:  2004-08       Impact factor: 4.379

3.  Objective and subjective hardness of a test item used for evaluating food mixing ability.

Authors:  N M Salleh; K Fueki; N R Garrett; T Ohyama
Journal:  J Oral Rehabil       Date:  2007-03       Impact factor: 3.837

4.  Within-subject comparisons of implant-supported mandibular prostheses: evaluation of masticatory function.

Authors:  J S Feine; K Maskawi; P de Grandmont; W B Donohue; R Tanguay; J P Lund
Journal:  J Dent Res       Date:  1994-10       Impact factor: 6.116

Review 5.  Assessment of mastication with implications for oral rehabilitation: a review.

Authors:  Andries van der Bilt
Journal:  J Oral Rehabil       Date:  2011-01-17       Impact factor: 3.837

6.  Effects on human maximum bite force of biting on a softer or harder object.

Authors:  J Paphangkorakit; J W Osborn
Journal:  Arch Oral Biol       Date:  1998-11       Impact factor: 2.633

7.  Bite force and influential factors on bite force measurements: a literature review.

Authors:  Duygu Koc; Arife Dogan; Bulent Bek
Journal:  Eur J Dent       Date:  2010-04

8.  Neuromuscular coordination of masticatory muscles in subjects with two types of implant-supported prostheses.

Authors:  Virgilio F Ferrario; Gianluca M Tartaglia; Michele Maglione; Massimo Simion; Chiarella Sforza
Journal:  Clin Oral Implants Res       Date:  2004-04       Impact factor: 5.977

9.  An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures.

Authors:  Tejomaya Shastry; N M Anupama; Shilpa Shetty; M Nalinakshamma
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

10.  A study on the evaluation of bite force, prosthetic and nutritional status in adult cleft patients in Kolkata.

Authors:  Alak Kumar Bera; Samiran Das; Jayanta Bhattacharyya; Sayan Majumdar; Saumitra Ghosh; Preeti Goel
Journal:  J Indian Prosthodont Soc       Date:  2018 Oct-Dec
View more
  2 in total

1.  Biomechanical Behavior of All-on-4 and M-4 Configurations in an Atrophic Maxilla: A 3D Finite Element Method.

Authors:  Delal Bozyel; Simge Taşar Faruk
Journal:  Med Sci Monit       Date:  2021-03-28

2.  The Reliability of a New Device for Measuring the Maximum Bite Force.

Authors:  Santosh R Patil; G Maragathavalli; D N S V Ramesh; Giridhar S Naidu; Mohammad Khursheed Alam; Ibrahim A AlZoubi
Journal:  Biomed Res Int       Date:  2022-01-13       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.