Literature DB >> 9094079

Reduction of motion artifacts in cine MRI using variable-density spiral trajectories.

J R Liao1, J M Pauly, T J Brosnan, N J Pelc.   

Abstract

Dynamic cardiac imaging in MRI is a very challenging task. To obtain high spatial resolution, temporal resolution, and signal-to-noise ratio (SNR), single-shot imaging is not sufficient. Use of multishot techniques resolves this problem but can cause motion artifacts because of data inconsistencies between views. Motion artifacts can be reduced by signal averaging at some cost in increased scan time. However, for the same increase in scan time, other techniques can be more effective than simple averaging in reducing the artifacts. If most of the energy of the inconsistencies is limited to a certain region of kappa-space, increased sampling density (oversampling) in this region can be especially effective in reducing motion artifacts. In this work, several variable-density spiral trajectories are designed and tested. Their efficiencies for artifact reduction are evaluated in computer simulations and in scans of normal volunteers. The SNR compromise of these trajectories is also investigated. The authors conclude that variable-density spiral trajectories can effectively reduce motion artifacts with a small loss in SNR as compared with a uniform density counterpart.

Entities:  

Mesh:

Year:  1997        PMID: 9094079     DOI: 10.1002/mrm.1910370416

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

Review 1.  Measurement techniques for magnetic resonance imaging of fast relaxing nuclei.

Authors:  Simon Konstandin; Armin M Nagel
Journal:  MAGMA       Date:  2013-07-24       Impact factor: 2.310

Review 2.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

3.  Evaluation of segmented 3D acquisition schemes for whole-brain high-resolution arterial spin labeling at 3 T.

Authors:  Marta Vidorreta; Evelyne Balteau; Ze Wang; Enrico De Vita; María A Pastor; David L Thomas; John A Detre; María A Fernández-Seara
Journal:  NMR Biomed       Date:  2014-09-26       Impact factor: 4.044

4.  Patient specific prospective respiratory motion correction for efficient, free-breathing cardiovascular MRI.

Authors:  Michael A Bush; Rizwan Ahmad; Ning Jin; Yingmin Liu; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2019-02-14       Impact factor: 4.668

5.  Accelerated MRI with CIRcular Cartesian UnderSampling (CIRCUS): a variable density Cartesian sampling strategy for compressed sensing and parallel imaging.

Authors:  Jing Liu; David Saloner
Journal:  Quant Imaging Med Surg       Date:  2014-02

6.  Multiparametric oxygen-enhanced functional lung imaging in 3D.

Authors:  Kathrin R F Hemberger; Peter M Jakob; Felix A Breuer
Journal:  MAGMA       Date:  2014-10-09       Impact factor: 2.310

7.  Quantitative T2 mapping using accelerated 3D stack-of-spiral gradient echo readout.

Authors:  Ruoxun Zi; Dan Zhu; Qin Qin
Journal:  Magn Reson Imaging       Date:  2020-08-27       Impact factor: 2.546

8.  Assessment of functional development in normal infant brain using arterial spin labeled perfusion MRI.

Authors:  Ze Wang; María Fernández-Seara; David C Alsop; Wen-Ching Liu; Judy F Flax; April A Benasich; John A Detre
Journal:  Neuroimage       Date:  2007-10-05       Impact factor: 6.556

9.  High efficiency, low distortion 3D diffusion tensor imaging with variable density spiral fast spin echoes (3D DW VDS RARE).

Authors:  Lawrence R Frank; Youngkyoo Jung; Souheil Inati; J Michael Tyszka; Eric C Wong
Journal:  Neuroimage       Date:  2009-09-22       Impact factor: 6.556

10.  Optimized 3D ultrashort echo time pulmonary MRI.

Authors:  Kevin M Johnson; Sean B Fain; Mark L Schiebler; Scott Nagle
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.