Literature DB >> 9091942

Detection of titanium in human tissues after craniofacial surgery.

D S Jorgenson1, M H Mayer, R G Ellenbogen, J A Centeno, F B Johnson, F G Mullick, P N Manson.   

Abstract

Generally, titanium fixation plates are not removed after osteosynthesis, because they have high biocompatability and high corrosion resistance characteristics. Experiments with laboratory animals, and limited studies of analyses of human tissues, have reported evidence of titanium release into local and distant tissues. This study summarizes our results of the analysis of soft tissues for titanium in four patients with titanium microfixation plates. Energy dispersive x-ray analysis, scanning electron microscopy, and electrothermal atomic absorption spectrophotometry were used to detect trace amounts of titanium in surrounding soft tissues. A single metal inclusion was detected by scanning electron microscopy and energy dispersive x-ray analysis in one patient, whereas, electrothermal atomic absorption spectrophotometry analyses revealed titanium present in three of four specimens in levels ranging from 7.92 to 31.8 micrograms/gm of dry tissue. Results from this study revealed trace amounts of titanium in tissues surrounding craniofacial plates. At the atomic level, electrothermal atomic absorption spectrophotometry appears to be a sensitive tool to quantitatively detect ultra-trace amounts of metal in human tissue.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9091942     DOI: 10.1097/00006534-199704000-00006

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  17 in total

1.  Choice of internal rigid fixation materials in the treatment of facial fractures.

Authors:  Mirko S Gilardino; Elliot Chen; Scott P Bartlett
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2009-03

2.  Biodegradable fixation for craniomaxillofacial surgery: a 10-year experience involving 761 operations and 745 patients.

Authors:  T A Turvey; W P Proffit; C Phillips
Journal:  Int J Oral Maxillofac Surg       Date:  2010-12-24       Impact factor: 2.789

Review 3.  The Recent Revolution in the Design and Manufacture of Cranial Implants: Modern Advancements and Future Directions.

Authors:  David J Bonda; Sunil Manjila; Warren R Selman; David Dean
Journal:  Neurosurgery       Date:  2015-11       Impact factor: 4.654

4.  Release of elements from retrieved maxillofacial plates and screws.

Authors:  C Bertoldi; J M Pradelli; U Consolo; D Zaffe
Journal:  J Mater Sci Mater Med       Date:  2005-09       Impact factor: 3.896

5.  Resorbable Versus Titanium Rigid Fixation for Pediatric Mandibular Fractures: A Systematic Review, Institutional Experience and Comparative Analysis.

Authors:  Matthew E Pontell; Eva B Niklinska; Stephane A Braun; Nolan Jaeger; Kevin J Kelly; Michael S Golinko
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2021-06-21

6.  The use of a single titanium microplate in displaced pediatric parasymphysial mandibular fractures.

Authors:  Walid A Abdullah
Journal:  Saudi Dent J       Date:  2009-07

7.  Early experience with biodegradable implants in pediatric patients.

Authors:  Andreas F Mavrogenis; Anastasios D Kanellopoulos; George N Nomikos; Panayiotis J Papagelopoulos; Panayotis N Soucacos
Journal:  Clin Orthop Relat Res       Date:  2008-10-02       Impact factor: 4.176

8.  Resorbable implants in maxillofacial surgery: a reality check.

Authors:  Suresh Menon; Col Sk Roy Choudhury
Journal:  J Maxillofac Oral Surg       Date:  2011-04-07

9.  A comparative study on evaluation of role of 1.5 mm microplates and 2.0 mm standard miniplates in management of mandibular fractures using bite force as indicator of recommendation.

Authors:  Syed Sayeed Ahmed; Sajjad Abdur Rehman; Md Kalim Ansari; Abid Ali Khan; Omar Farooq; Arshad Hafeez Khan
Journal:  Natl J Maxillofac Surg       Date:  2016 Jan-Jun

10.  Evaluation of the Fatigue Performance and Degradability of Resorbable PLDLLA-TMC Osteofixations.

Authors:  Constantin Landes; Alexander Ballon; Shahram Ghanaati; Daniel Ebel; Dieter Ulrich; Uwe Spohn; Ute Heunemann; Robert Sader; Raimund Jaeger
Journal:  Open Biomed Eng J       Date:  2013-11-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.