Literature DB >> 18830794

Early experience with biodegradable implants in pediatric patients.

Andreas F Mavrogenis1, Anastasios D Kanellopoulos, George N Nomikos, Panayiotis J Papagelopoulos, Panayotis N Soucacos.   

Abstract

UNLABELLED: We retrospectively studied nine children and adolescents with congenital malformations, large reconstruction after tumor excision, fractures and osteotomies of the upper extremity, and hand trauma with bone and soft tissue defects treated by internal synthesis using a biocopolymer of L- and DL-stereoisomers of lactic acid polymers and trimethylenecarbonate. A total of 52 biodegradable implants were placed in bone. At a minimum followup of 7 months (mean, 17 months; range, 7-22 months), wound healing was uncomplicated; local or systemic inflammatory tissue reactions, foreign body reactions, and infections were not observed. Bone healing was complete. Six biodegradable screws broke during insertion because of inadequate drilling and tapping, and three biodegradable screws had to be replaced because of damage to the screw head during assembly with the screwdriver. Biodegradable copolymers of poly-L-lactic-poly-DL-lactic acid and trimethylenecarbonate can be used safely and effectively for reconstruction and fixation of bone in children and adolescents. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18830794      PMCID: PMC2674157          DOI: 10.1007/s11999-008-0537-4

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  40 in total

Review 1.  The future of biodegradable osteosyntheses.

Authors:  F W Cordewener; J P Schmitz
Journal:  Tissue Eng       Date:  2000-08

2.  Wound infections associated with absorbable or metallic devices used in the fixation of fractures, arthrodeses and osteotomies.

Authors:  I Sinisaari; H Pätiälä; O Böstman; E A Mäkelä; E Hirvensalo; E K Partio; P Törmälä; P Rokkanen
Journal:  Eur J Orthop Surg Traumatol       Date:  1995-12

3.  Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers.

Authors:  O Böstman; E Hirvensalo; J Mäkinen; P Rokkanen
Journal:  J Bone Joint Surg Br       Date:  1990-07

4.  The removal of plates and screws after Le Fort I osteotomy.

Authors:  B L Schmidt; D H Perrott; D Mahan; G Kearns
Journal:  J Oral Maxillofac Surg       Date:  1998-02       Impact factor: 1.895

5.  Synthetic biodegradable polymers as orthopedic devices.

Authors:  J C Middleton; A J Tipton
Journal:  Biomaterials       Date:  2000-12       Impact factor: 12.479

6.  Detection of titanium in human tissues after craniofacial surgery.

Authors:  D S Jorgenson; M H Mayer; R G Ellenbogen; J A Centeno; F B Johnson; F G Mullick; P N Manson
Journal:  Plast Reconstr Surg       Date:  1997-04       Impact factor: 4.730

7.  Resorbable screws for fixation of autologous bone grafts.

Authors:  Gerry M Raghoebar; Robert S B Liem; Rudolf R M Bos; Jacqueline E van der Wal; Arjan Vissink
Journal:  Clin Oral Implants Res       Date:  2006-06       Impact factor: 5.977

Review 8.  Adverse tissue reactions to bioabsorbable fixation devices.

Authors:  O M Böstman; H K Pihlajamäki
Journal:  Clin Orthop Relat Res       Date:  2000-02       Impact factor: 4.176

9.  Monitoring the degradation process of biopolymers by ultrasonic longitudinal wave pulse-echo technique.

Authors:  Hsueh-Chang Wu; Fu-Wen Shen; Xuan Hong; Wenji V Chang; Howard Winet
Journal:  Biomaterials       Date:  2003-10       Impact factor: 12.479

10.  Biodegradable fixation of distal humeral physeal fractures.

Authors:  E A Mäkelä; O Böstman; M Kekomäki; J Södergård; J Vainio; P Törmälä; P Rokkanen
Journal:  Clin Orthop Relat Res       Date:  1992-10       Impact factor: 4.176

View more
  4 in total

1.  Delayed foreign-body reaction to absorbable implants in metacarpal fracture treatment.

Authors:  Panagiotis K Givissis; Stavros I Stavridis; Panayiotis J Papagelopoulos; Petros D Antonarakos; Anastasios G Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-05-15       Impact factor: 4.176

2.  Resorbable osteosynthetic devices in pediatric traumatology: a prospective series of 24 cases.

Authors:  J M Poircuitte; D Popkov; P Popkov; H Huber; D H Huber; E Polirsztok; P Lascombes; P Journeau
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-06-18

3.  Isolated trochlea osteochondral fracture of the distal humerus in a 6-year-old patient surgically fixed using biodegradable pins: A case study with over 3 years of follow-up.

Authors:  Nobuaki Tsukamoto; Takao Mae; Kenichi Hirabayashi; Yu Matsushita; Satoshi Baba; Norihiro Komiya; Mitsumasa Hayashida
Journal:  Trauma Case Rep       Date:  2022-06-01

4.  Αbsorbable Plates for Isolated Ulnar Diaphyseal Fractures in Adults - A Case Series Study.

Authors:  Dimitrios Kapoutsis; Dimitrios Kitridis; Nikolaos Platon Sachinis; Avraam Ploumis; Panagiotis Givissis
Journal:  J Orthop Case Rep       Date:  2020-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.