Literature DB >> 28163477

A comparative study on evaluation of role of 1.5 mm microplates and 2.0 mm standard miniplates in management of mandibular fractures using bite force as indicator of recommendation.

Syed Sayeed Ahmed1, Sajjad Abdur Rehman1, Md Kalim Ansari1, Abid Ali Khan2, Omar Farooq3, Arshad Hafeez Khan4.   

Abstract

AIMS AND
OBJECTIVES: To compare the maximum voluntary bite force generated at different periods during mandibular fracture healing using miniplates and microplates as means of rigid internal fixation.
MATERIALS AND METHODS: Maximum voluntary bite force was recorded in healthy young individuals of different age group from either gender. Patients suffering from symphyseal and parasymphyseal and body fractures were selected and randomly treated using miniplate and microplate osteosynthesis by open reduction and rigid internal fixation. Postoperative bite forces at intervals of 1st, 2nd, 4th, and 6th week were recorded and compared with control group. OBSERVATIONS AND
RESULTS: It was noticed that bite forces were significantly reduced in the study groups in comparison to control group and at different intervals of treatment. There was a progressive improvement in the bite force with passage of time. There was no statistical significance in the observed bite force in both the study groups at different intervals of assessment.
CONCLUSION: 1.5 mm microplates provide adequate stability comparable to miniplates for the treatment of fractured mandible and should be preferred over miniplates. We further suggest that bite forces should be considered for the assessment of clinical union of bone as well as studies pertaining to selection of hardware for rigid internal fixation.

Entities:  

Keywords:  Healing of fractures; metal leaching; microplates; rigid internal fixation; voluntary bite force

Year:  2016        PMID: 28163477      PMCID: PMC5242073          DOI: 10.4103/0975-5950.196128

Source DB:  PubMed          Journal:  Natl J Maxillofac Surg        ISSN: 0975-5950


Introduction

Fractures of mandible are commonly treated by rigid internal fixation using 2.0 miniplates to restore the normal form and function. With time, an evolution in size and shape of fixation devices has taken place. Michelet et al.[1] in 1973 introduced the miniplate osteosynthesis and Champy et al.[2] further developed Champy's concept and described ideal lines of osteosynthesis for placement and fixation of plates in various regions for mandibular fracture. These miniplates are available in different designs, sizes, shapes, number of wholes, and they are fixed by screws of different sizes. There are reports which indicate that leaching of metal takes place in the adjacent tissues of plates as well as peripheral organs after osteosynthesis.[3456] Thus, the size of hardware should be optimized not only to resist the masticatory stresses, to provide sufficient stability to the bone segments and restoration of normal masticatory function but also to leaching of metal. Evans et al.[7] performed their studies and suggested the role of miniplates and microplates in treatment of mandibular and midfacial fractures. Feller et al.[8] performed biomechanical studies and suggested that a combination of miniplate and microplate provided sufficient stability for complication-free healing of fractures. Gupta et al.[9] studied the bite forces with such combination and confirmed the findings of the Feller. This was, in fact, an effort to advocate the minimum use of hardware. This effort must have minimized the metal leaching also. Available data indicate that bite forces are reduced in traumatized mandible and biting, and masticatory forces are severely compromised as the tissue environment is significantly altered,[1011] thus affecting the biting force. In such situation, a combination of 1.5 mm microplates may be adequate to bear the masticatory stresses and must provide sufficient stability as tensile forces at which permanent deformation takes place in these plates are much higher than the bite forces to which these plates are exposed in the healing phase of bone. On the basis of available data of masticatory forces in fractured mandible, we gave a null hypothesis that microplates, if used in mandibular fractures would be sufficient to provide stability to fractured bone and resist masticatory forces.

Aims and objectives

The aims and objectives of the study were to compare bite forces generated in patients treated with 2.0 mm miniplates or 1.5 mm microplates in symphyseal and parasymphyseal fractures at postoperative interval of 1 week, 2 weeks, 4 weeks, and 6 weeks and to compare the efficacy of these plates in the treatment of mandibular fractures.

Materials and Methods

Study sample collection

The study was approved by the Institutional Ethical Committee and was conducted at Department of Oral and Maxillofacial Surgery, Dr. Ziauddin Ahmad Dental College, Aligarh Muslim University, Aligarh. To perform the study, data for maximum voluntary bite force in control group were collected on young volunteers of different age group among which were dental students and employees of dental college. The exclusion criteria included volunteers which were (1) partially or completely edentulous, (2) medically compromised, and (3) with preexisting dental pain or myofascial pain. The patients in study Group I were treated by open reduction and rigid internal fixation (ORIF) using 1.5 mm microplates and in Group II using 2.0 miniplates. Both the plates with screws were supplied by M/S Loyal Surgicals, Mumbai, for the purpose of the study.

Bite force recording equipment

A bite force recorder [Figure 1] was developed at Division of Ergonomics, Department of Mechanical Engineering, Aligarh Muslim University, Aligarh, which consisted of a transducer based on Wheatstone bridge which worked as pressure sensing device, a digital electronic display, and an adjustable knob for adjusting zero of the display. The equipment consisted of metallic fork covered with disposable cushioned adhesive tape which was meant for force application. The equipment was connected to 250V electrical supply for charging backup of equipment. The consistency and accuracy of bite force were reaffirmed by doing detailed laboratory and clinical testing on fifty individuals.
Figure 1

Bite force recorder with biting fork

Bite force recorder with biting fork The participants in the study were fully made aware of bite force recording equipment and then mechanism of recording. The pressure fork was covered with sterile adhesive tape which was soft and had cushioning property and gave a feeling of comfort on biting on it. The fork was covered with sterile gloves for further sterility. After every patient, the fork was cleaned, adhesive tape changed, and then covered in sterile gloves. The patients were asked to bite on the fork from anterior as well as left and right molar teeth. The findings were recorded in specially designed format, and results were statistically analyzed.

Data collection

The bite force was recorded by asking the participant to bite on fork by maximum pressure from front teeth and by occluding the molars. Each volunteer/patient was asked to sit erect and relaxed keeping the head in Frankfort horizontal plane parallel to ground floor. Three successive readings were taken on either side after giving a rest of 10 s on each side and highest value biting force was considered as maximum bite force.

Study groups

For analyzing the data, three study groups were made: Control: Healthy young volunteers Group I: Patients treated with miniplate for symphyseal/parasymphyseal/body fractures Group II: Patients treated with microplates for symphyseal/parasymphyseal/body fractures.

Observations and Results

The individuals of control group underwent for single stage data collection while the patients of Group I and II were called for follow-up at postoperative interval of end of 1st, 2nd, 4th, and 6th week. All the patients were treated by the same surgeon and treated according to clinical situation by intra-/extra-oral open reduction and rigid fixation using miniplates or microplates [Figure 2a–c]. To prevent the bias, every alternate patient was treated by miniplates and microplates.
Figure 2

(a) Open reduction and rigid internal fixation in parasymphysis region. (b) Open reduction and rigid internal fixation in the body region. (c) Open reduction and rigid internal fixation in parasymphysis by extraoral route

(a) Open reduction and rigid internal fixation in parasymphysis region. (b) Open reduction and rigid internal fixation in the body region. (c) Open reduction and rigid internal fixation in parasymphysis by extraoral route Thirty healthy volunteers in control group and forty patients, with twenty patients in each study group (Group I and Group II), were included in the study. The average age of volunteers in control group was 26.3 years (age range, 18–34), in patients of Group I was 30.6 years (age range, 18–55 years), in Group II was 30.7 years (age range, 19–55 years). Table 1 shows gender-wise distribution of patients and Table 2 shows site-wise distribution of cases operated in each study group and Table 3 shows average bite force observed in volunteers under control group.
Table 1

Gender-wise distribution of patients

Table 2

Site-wise distribution of patients

Table 3

Mean bite force in control group

Gender-wise distribution of patients Site-wise distribution of patients Mean bite force in control group Table 4 reveals the values of preoperative bite forces with their standard deviation in study Groups I and II and Table 5a and b shows week-wise changes in bite force in study groups.
Table 4

Preoperative bite forces in study groups

Table 5a

Week-wise changes in bite force in study Group I

Table 5b

Week-wise changes in bite force in study Group II

Preoperative bite forces in study groups Week-wise changes in bite force in study Group I Week-wise changes in bite force in study Group II

Statistical data

The data were analyzed using online software GraphPad software Quick Calcs from website: http://www.graphpad.com/quickcalcs/ttest2/. Table 6 shows P values of bite force in anterior and left and right posterior region. Table 7a–c shows postoperative P values of bite force observed in anterior and left and right posterior region of study groups at different intervals.
Table 6

Preoperative bite force in study groups

Table 7a

Week-wise changes in incisor bite force

Table 7c

Week-wise changes in molar bite force (right side)

Preoperative bite force in study groups Week-wise changes in incisor bite force Week wise changes in molar bite force (left side) Week-wise changes in molar bite force (right side) The bite forces in different study groups after rigid fixation and different weeks of recovery were recorded. It was noticed that the incisor bite force was significantly reduced in the first 6 weeks after ORIF when it was compared with the patients after the 6th postoperative week and the controls (P < 0.001). In week 1, the incisor bite force was 2.5 and 2.8 kg, respectively, in Group I and Group II which raised to 12.8 and 12.5 in incisor region. In the molar region, the bite force in Group I was 30.7 and 30.8 kg at the end of 6th postoperative week, which was 8.3 and 8.9 kg at the end of 1st postoperative week in right and left molar region, respectively [Figure 3].
Figure 3

Bar diagram showing maximum voluntary bite force in control group, and 6 weeks postoperative bite forces in Group I and Group II in incisor, left molar, and right molar region

Bar diagram showing maximum voluntary bite force in control group, and 6 weeks postoperative bite forces in Group I and Group II in incisor, left molar, and right molar region In Group II, the bite force in molar region was 30.4 and 31.7 kg at the end of 6th postoperative week, which was 9.3 and 9.7 kg at the end of 1st postoperative week in right and left molar region, respectively. Thus, a significant reduction in molar bite force occurred in patients of each group and in the region of interest when compared with 6 week postoperative bite force and with the control values (P< 0.001). There was a progressive improvement in bite forces with elapse of time which indicated the repair of soft tissues as well as healing of the bone.

Complications

Within the two study groups, of twenty patients each, who were treated according to Champy's principle and by ORIF. Overall complications were recorded in five patients (12.5%) in both study groups. One patient required revision surgery, two patients had occlusal disturbance, one had abscess in fracture line, and one had dehiscence. Altogether 35 patients (87.5%) were treated successfully without any complication. The occlusal disturbance was corrected by occlusal grinding; abscess was simply managed by standard methods treating infection and did not require plate removal. However, the case in which there was wound dehiscence exposing plate was treated by plate removal followed by intermaxillary fixation; the overall success may be said as 38/40, i.e., 95%. Hence, it may be said that overall success rate was 95%. Hypoesthesia was not seen in Group I cases whereas it was seen in only case in Group II. Disturbed occlusion was seen in Group II and none in Group I. Majority of the complications were managed by routine OPD procedure.

Discussion

The measurement of bite forces has been remained a matter of interest among researchers. However, there is inconsistency in the findings and maximum value of bite forces presented by different authors.[9111213] The reasons of this variation may be many. The device used to record the bite force, its sensitivity, comfort of the volunteer, and psychological state of volunteer. In addition, genetic and ethnic, food habits, and geographical factors may be also responsible for this variation. Individual neuromuscular mechanism may itself be also an important factor for this difference.[1415] There is individual variation in masticatory forces or bite force. Maximum bite force is the greatest force that an individual can generate by voluntary clenching of teeth in the occlusal position. We measured the maximum bite in young men and women healthy volunteers which was taken as control to compare with patients in the study group. We found that the bite forces in control group in incisor region were 16.3 kg, right molar region 50.6 kg, and left molar region were 52.1 kg. These forces are generated due to interaction of masticatory muscle forces and must be overcome by desired treatment. In a similar study, Gupta et al.[7] found that voluntary bite force in a healthy adult was on the order of 15.4 kp in the incisor and 48.3 and 49.2 kp in the left and right molar regions, respectively. Our findings are much closure to findings of Gupta et al.[7] which may be due to volunteers belong to same geographical location and had similar food habits. In our study, it was noticed that preoperative forces were highly significant in molar regions of study group [Table 4]. These values may be just by chance and practically bear no clinical significance. However, the bite forces progressively increased in each study group, and their comparative value remained insignificant throughout the phase of recovery [Table 7a–c]. However, by the end of 6th weeks, patients in either group regained 60% in molar region and 75% in anterior region. This pattern of recovery can be attributed to psychological state of patient as if they themselves avoid applying heavy chewing forces due to fear of refracture of jaw or any disturbance in normal healing. This can be also inferred that 60% of maximum bite force is usually sufficient for comfortable chewing. It has been suggested that the amount of force used during functional activity is much less than the voluntary bite force. It is further reduced in trauma affairs. Therefore, the fixation requirements based on the maximum voluntary bite force in noninjured participants may be more there for the monocortical fixation has been used successfully.[89] The reason for reduced bite force after treatment by open reduction and rigid fixation is injury to not only bone but also investing periosteum and associated muscles in the adjacent area. Formation of hematoma in the region itself may affect the movement. In addition, surgical trauma to muscles and periosteum may also restrict the normal function of the body until healing has taken place. Intra- or extra-oral placement of fixation hardware necessitates the placement of incision, reflection of mucoperiosteal flap and in selected cases incising the muscle fibers as well. All these reasons of trauma are responsible for compromised masticatory function until healing is completed. Our findings are important to recommend the use of 1.5 system microplates for treatment of mandibular fractures. As there is no significant difference in the bite force generated when microplates are used, in comparison to miniplates, and they provide adequate stability to fractured segment, their use may be recommended for routine use. Another important aspect is minimization of metal leaching in the adjacent tissues. This is perhaps first study, in which bite forces have been compared with miniplate and microplate. On the basis of our findings, we recommend that microplates should be preferably used for mandibular fracture. Kumar et al.[16] observed that patients treated with locking plate/screw system postoperatively generated more bite force compared to those treated with conventional miniplate screw system. However, they have not highlighted the significance of their findings in statistical terms. The increase in bite force may be due to mechanical advantage provided by locking plate. On the basis of available data, we are able to demonstrate that major complications were rare (5%) using microplate and miniplate osteosynthesis. This furthers proves that microplates are equally good as miniplates as far as linear fractures are concerned. However, for comminuted fractures, more rigid plates should be used.

Conclusion

On the basis of our study we conclude that 1.5 mm microplates are rigid enough to provide adequate stability to the fractured segments which is comparable to miniplates in the isolated fractures of mandible and should be preferred over miniplates. In addition the bite forces should be considered for the assessment of clinical union of bone as well as studies pertaining to selection of hardware for rigid internal fixation.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
Table 7b

Week wise changes in molar bite force (left side)

  15 in total

1.  Osteosynthesis with miniaturized screwed plates in maxillo-facial surgery.

Authors:  F X Michelet; J Deymes; B Dessus
Journal:  J Maxillofac Surg       Date:  1973-06

2.  Detection of titanium in human tissues after craniofacial surgery.

Authors:  D S Jorgenson; M H Mayer; R G Ellenbogen; J A Centeno; F B Johnson; F G Mullick; P N Manson
Journal:  Plast Reconstr Surg       Date:  1997-04       Impact factor: 4.730

3.  Bite force and influential factors on bite force measurements: a literature review.

Authors:  Duygu Koc; Arife Dogan; Bulent Bek
Journal:  Eur J Dent       Date:  2010-04

4.  Ultrastructural findings in soft tissues adjacent to titanium plates used in jaw fracture treatment.

Authors:  H Schliephake; H Lehmann; U Kunz; R Schmelzeisen
Journal:  Int J Oral Maxillofac Surg       Date:  1993-02       Impact factor: 2.789

5.  Mandibular osteosynthesis by miniature screwed plates via a buccal approach.

Authors:  M Champy; J P Loddé; R Schmitt; J H Jaeger; D Muster
Journal:  J Maxillofac Surg       Date:  1978-02

6.  A preliminary study of maximum voluntary bite force and jaw muscle efficiency in pre-orthognathic surgery patients.

Authors:  J S Dean; G S Throckmorton; E Ellis; D P Sinn
Journal:  J Oral Maxillofac Surg       Date:  1992-12       Impact factor: 1.895

Review 7.  Role of mini- and microplate fixation in fractures of the midface and mandible.

Authors:  G R Evans; N Clark; P N Manson; L S Leipziger
Journal:  Ann Plast Surg       Date:  1995-05       Impact factor: 1.539

8.  Bite forces in patients treated for mandibular angle fractures: implications for fixation recommendations.

Authors:  G S Tate; E Ellis; G Throckmorton
Journal:  J Oral Maxillofac Surg       Date:  1994-07       Impact factor: 1.895

9.  Effect of gender, facial dimensions, body mass index and type of functional occlusion on bite force.

Authors:  Duygu Koç; Arife Doğan; Bülent Bek
Journal:  J Appl Oral Sci       Date:  2011 May-Jun       Impact factor: 2.698

10.  Comparative evaluation of bite forces in patients after treatment of mandibular fractures with miniplate osteosynthesis and internal locking miniplate osteosynthesis.

Authors:  Saurab Kumar; Shashank Reddy Gattumeedhi; Bharat Sankhla; Akshay Garg; Ekta Ingle; Namrata Dagli
Journal:  J Int Soc Prev Community Dent       Date:  2014-11
View more
  1 in total

1.  Comparison of biting force when using a combination of one microplate and one miniplate versus two miniplates for fixation of parasymphyseal mandibular fracture: the use of microplates for parasymphyseal mandibular fracture.

Authors:  Magdy Mohamed Zaky; Nabila Ali Fayed; Mohamed Farid Shehab
Journal:  Oral Maxillofac Surg       Date:  2019-11-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.