Literature DB >> 9080236

Improved assessment of intravascular Doppler coronary flow velocity profile.

E Wellnhofer1, W Finke, L Bernard, W Dänschel, E Fleck.   

Abstract

Easy and safe in-vivo flow velocity studies in small coronary arteries have become feasible using a 0.014 'or 0.018' guidewire with an integrated Doppler probe in its tip (FloWire, Cardiometrics). Assessment of the flow velocity profile by the ratio of diastolic to systolic flow velocity (DSVR) is used as a diagnostic parameter. However, DSVR is a coarse quantifier of the flow velocity profile, and is subject to large physiologic variance and depends crucially on the quality of the Doppler signal. The aim of our study was to test parameters derived from statistical time series analysis for monitoring the quality of the instantaneous peak velocity (IPV) signal. Improvement of quantification of changes in quality and shape of flow velocity profiles by these parameters as compared to DSVR was a second goal. We investigated analog-digital converted IPV-signals and video registrations of corresponding greyscale spectra of intracoronary Doppler flow velocity signals. The signals were analyzed by using the autocorrelation function (ACF) in the time domain and a fast Fourier transform (FFT) in the frequency domain (standard time series statistics). The first minimum of autocorrelation function turned out to be very sensitive to signal quality, and Fisher's g of the periodogram was the parameter of choice for shape analysis. In 11 patients with coronary artery disease, pre and post PTCA, the sensitivity of DSVR and signal to noise ratio to changes in shape and quality of the flow velocity signals was compared to that of the new parameters. Nineteen Doppler flow velocity samples of good quality from measurements in nonstenotic vessels and 7 flow velocity tracings with visible artefacts were used to assess the value of these parameters in monitoring signal quality. By comparison with corresponding parameters in use (SNR and DSVR) a significantly improved performance of the new statistical parameters was observed with respect to sensitivity to changes in signal quality and flow profile. In view of these results and because of the short calculation time of these variables they should be used for on-line quality control and analysis of flow velocity profiles.

Entities:  

Mesh:

Year:  1997        PMID: 9080236     DOI: 10.1023/a:1005714629995

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  9 in total

1.  Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity.

Authors:  J W Doucette; P D Corl; H M Payne; A E Flynn; M Goto; M Nassi; J Segal
Journal:  Circulation       Date:  1992-05       Impact factor: 29.690

2.  Review of hydrodynamic principles for the cardiologist: applications to the study of blood flow and jets by imaging techniques.

Authors:  A P Yoganathan; E G Cape; H W Sung; F P Williams; A Jimoh
Journal:  J Am Coll Cardiol       Date:  1988-11       Impact factor: 24.094

3.  Effect of stenosis geometry on the Doppler-catheter gradient relation in vitro: a manifestation of pressure recovery.

Authors:  H Baumgartner; H Schima; G Tulzer; P Kühn
Journal:  J Am Coll Cardiol       Date:  1993-03-15       Impact factor: 24.094

4.  Analysis of coronary blood flow velocity dynamics in angiographically normal and stenosed arteries before and after endolumen enlargement by angioplasty.

Authors:  E O Ofili; M J Kern; A J Labovitz; J A St Vrain; J Segal; F V Aguirre; R Castello
Journal:  J Am Coll Cardiol       Date:  1993-02       Impact factor: 24.094

5.  Variations in acoustical beam properties of intracoronary Doppler catheters.

Authors:  T Roth; R Erbel; R Brennecke; H J Rupprecht; J Meyer; W von Seelen
Journal:  Cathet Cardiovasc Diagn       Date:  1993-11

6.  Coronary artery flow monitoring following coronary interventions.

Authors:  H V Anderson; R L Kirkeeide; Y Stuart; R W Smalling; J Heibig; J T Willerson
Journal:  Am J Cardiol       Date:  1993-05-20       Impact factor: 2.778

7.  Alterations of phasic coronary artery flow velocity in humans during percutaneous coronary angioplasty.

Authors:  J Segal; M J Kern; N A Scott; S B King; J W Doucette; R R Heuser; E Ofili; R Siegel
Journal:  J Am Coll Cardiol       Date:  1992-08       Impact factor: 24.094

8.  Assessment of coronary conductance and resistance vessel reactivity in response to nitroglycerin, ergonovine and adenosine: in vivo studies with simultaneous intravascular two-dimensional and Doppler ultrasound.

Authors:  K Sudhir; J S MacGregor; S D Barbant; E Foster; P J Fitzgerald; K Chatterjee; P G Yock
Journal:  J Am Coll Cardiol       Date:  1993-04       Impact factor: 24.094

9.  Translesional pressure-flow velocity assessment in patients: Part I.

Authors:  M J Kern; F V Aguirre; R G Bach; E A Caracciolo; T J Donohue
Journal:  Cathet Cardiovasc Diagn       Date:  1994-01
  9 in total
  1 in total

1.  High fidelity correction of pressure signals from fluid-filled systems by harmonic analysis.

Authors:  E Wellnhofer; V Combé; H Oswald; E Fleck
Journal:  J Clin Monit Comput       Date:  1999-07       Impact factor: 2.502

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.