Interface pressures and shear stresses at thirteen socket sites on two persons with transtibial amputation.

J E Sanders1, D Lam, A J Dralle, R Okumura.   

Abstract

Residual limb/prosthetic socket interface pressures and shear stresses were measured at 13 sites on two subjects with unilateral transtibial amputation (TTA) using total-contact patellar-tendon-bearing prostheses. Maximal interface stresses during stance phase for each of 13 transducer sites were determined, then means for all steps calculated. Maximal pressure and resultant shear stress during stance phase were shown at anterior distal or mid-limb sites and the maxima occurred during the first 50% of stance phase. Anterior medial and lateral proximal sites showed their greatest pressure during the second 50%. At lateral mid-limb and popliteal fossa sites, resultant shear stress directions suggest that soft tissue was displaced toward the socket brim during weight-bearing. Results also suggest that skin across the distal tibial crest was in tension at the times of the first and second peaks in the shank axial force-time curve in all sessions. Significant difference (p < 0.05) in maximal stresses between sessions conducted > 3 weeks apart were apparent for both subjects.

Entities:  

Mesh:

Year:  1997        PMID: 9021623

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  13 in total

1.  Biomechanical evaluation of a prototype foot/ankle prosthesis.

Authors:  P M Quesada; M Pitkin; J Colvin
Journal:  IEEE Trans Rehabil Eng       Date:  2000-03

2.  Development of Standardized Material Testing Protocols for Prosthetic Liners.

Authors:  John C Cagle; Per G Reinhall; Brian J Hafner; Joan E Sanders
Journal:  J Biomech Eng       Date:  2017-04-01       Impact factor: 2.097

3.  A finite element model to assess transtibial prosthetic sockets with elastomeric liners.

Authors:  John C Cagle; Per G Reinhall; Kate J Allyn; Jake McLean; Paul Hinrichs; Brian J Hafner; Joan E Sanders
Journal:  Med Biol Eng Comput       Date:  2017-12-13       Impact factor: 2.602

4.  Amputee socks: Sock thickness changes with normal use.

Authors:  John C Cagle; Krittika J D'Silva; Brian J Hafner; Daniel S Harrison; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2015-03-02       Impact factor: 1.895

5.  Effects of socket size on metrics of socket fit in trans-tibial prosthesis users.

Authors:  Joan E Sanders; Robert T Youngblood; Brian J Hafner; John C Cagle; Jake B McLean; Christian B Redd; Colin R Dietrich; Marcia A Ciol; Katheryn J Allyn
Journal:  Med Eng Phys       Date:  2017-04-01       Impact factor: 2.242

6.  Amputee socks: how does sock ply relate to sock thickness?

Authors:  Joan E Sanders; John C Cagle; Daniel S Harrison; Ari Karchin
Journal:  Prosthet Orthot Int       Date:  2012-01-06       Impact factor: 1.895

7.  Mechanical Pain Sensitivity in Postamputation Pain.

Authors:  Emma H Beisheim-Ryan; Ryan T Pohlig; Gregory E Hicks; John R Horne; Jared Medina; Jaclyn M Sions
Journal:  Clin J Pain       Date:  2021-10-06       Impact factor: 3.423

8.  Amputee socks: thickness of multiple socks.

Authors:  John C Cagle; Alan J Yu; Marcia A Ciol; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2013-11-15       Impact factor: 1.895

9.  Textile-based Pressure Sensors for Monitoring Prosthetic-Socket Interfaces.

Authors:  Jordan Tabor; Talha Agcayazi; Aaron Fleming; Brendan Thompson; Ashish Kapoor; Ming Liu; Michael Lee; He Helen Huang; Alper Bozkurt; Tushar Ghosh
Journal:  IEEE Sens J       Date:  2021-01-21       Impact factor: 3.301

10.  Clinical implication of interface pressure for a new prosthetic suspension system.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Nasrul Anuar Abd Razak
Journal:  Biomed Eng Online       Date:  2014-06-30       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.