The impact of vessel orientation in space on densitometric measurements of cross sectional areas of coronary arteries.

P A Doriot1, P A Dorsaz, L Dorsaz, P Chatelain, W Rutishauser.   

Abstract

Under ideal conditions, densitometric measurement of a coronary arterial cross section in biplane angiographic images should result in nearly equal cross sectional areas for both planes. However, quite appreciable discrepancies have been found by some authors in patients. In this study, the role of inadequate spatial orientation of the vessel axes relatively to the x-rays was assessed by use of a 3D technique applied to 60 stenoses (45 pre PTCA and 15 post PTCA) in simultaneously acquired digital biplane coronary angiograms of 27 CAD patients. The 3D technique yields two radius values per projection directly in mm at any arterial cross section of interest. This was used to determine the areas Ar(in mm2) of the reference cross sections. As with catheter calibration, these cross sections were thus assumed to be more or less circular, but out-of-plane effects and errors due to a catheter diameter determination in pixels were avoided. The areas of the stenotic sections were then determined densitometrically (in mm2) from the two projections (1 and 2) according to As1 = ArDs1/Dr1, resp. As2 = ArDs2/Dr2, where Dr1, Dr2, Ds1 and Ds2 are the conventional densitometric areas of the reference and stenotic cross sections measured in planes 1 and 2. As expected, the areas As1 and As2 correlated only moderately: As2 = 0.92 As1 + 0.7 mm2, r = 0.82, n = 60, SEE = 1.4 mm2. The 3D method also yielded the two spatial angles between the local vessel axis and the X-rays of both planes. These two angles were then used to correct each densitometric area for inadequate orientation. With the corrected densitometric areas As1c and As2c, the correlation improved to: As2c = 1.05 As1c + 0.03 mm2, r = 0.93, n = 60, SEE = 0.8 mm2. Inadequate orientation of the cross sections in space thus appears to be an important factor of inaccuracy in densitometric measurements of stenotic cross sections in patients.

Entities:  

Mesh:

Year:  1996        PMID: 8993991     DOI: 10.1007/bf01797742

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  20 in total

1.  Spatial reconstruction of coronary arteries from angiographic images.

Authors:  N Guggenheim; P A Doriot; P A Dorsaz; P Descouts; W Rutishauser
Journal:  Phys Med Biol       Date:  1991-01       Impact factor: 3.609

2.  Morphometry versus densitometry--a comparison by use of casts of human coronary arteries.

Authors:  P A Doriot; C Suilen; N Guggenheim; P A Dorsaz; F Chappuis; W Rutishauser
Journal:  Int J Card Imaging       Date:  1992

Review 3.  Morphometric versus densitometric assessment of coronary vasomotor tone--an overview.

Authors:  P A Doriot; N Guggenheim; P A Dorsaz; W Rutishauser
Journal:  Eur Heart J       Date:  1989-11       Impact factor: 29.983

4.  Comparison of observer and videodensitometric measurements of simulated coronary artery stenoses.

Authors:  M A Simons; B V Bastian; B E Bray; D R Dedrickson
Journal:  Invest Radiol       Date:  1987-07       Impact factor: 6.016

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Three-dimensional densitometric reconstruction and visualization of stenosed coronary artery segments.

Authors:  J G van den Broek; C H Slump; C J Storm; A C van Benthem; B Buis
Journal:  Comput Med Imaging Graph       Date:  1995 Mar-Apr       Impact factor: 4.790

7.  Quantitative angiography during coronary angioplasty with a single angiographic view: a comparison of automated edge detection and videodensitometric techniques.

Authors:  J Escaned; D P Foley; J Haase; C Di Mario; W R Hermans; P J de Feyter; P W Serruys
Journal:  Am Heart J       Date:  1993-12       Impact factor: 4.749

8.  Can the same edge-detection algorithm be applied to on-line and off-line analysis systems? Validation of a new cinefilm-based geometric coronary measurement software.

Authors:  J Haase; M M van der Linden; C Di Mario; W J van der Giessen; D P Foley; P W Serruys
Journal:  Am Heart J       Date:  1993-08       Impact factor: 4.749

9.  Quantitation of absolute area of a coronary arterial stenosis: experimental validation with a preparation in vivo.

Authors:  J Wiesel; A M Grunwald; C Tobiasz; B Robin; M M Bodenheimer
Journal:  Circulation       Date:  1986-11       Impact factor: 29.690

10.  Assessment of dimensions and image quality of coronary contrast catheters from cineangiograms.

Authors:  J H Reiber; C J Kooijman; A den Boer; P W Serruys
Journal:  Cathet Cardiovasc Diagn       Date:  1985
View more
  1 in total

1.  Coronary pressure measurement to determine treatment strategy for equivocal left main coronary artery lesions.

Authors:  Shunji Suemaru; Kohichiro Iwasaki; Keizo Yamamoto; Shozo Kusachi; Kazuyoshi Hina; Satoshi Hirohata; Minoru Hirota; Masaaki Murakami; Shigeshi Kamikawa; Takashi Murakami; Yasushi Shiratori
Journal:  Heart Vessels       Date:  2005-11       Impact factor: 1.814

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.