Accuracy of home blood glucose meters during hypoglycemia.

Z Trajanoski1, G A Brunner, R J Gfrerer, P Wach, T R Pieber.   

Abstract

OBJECTIVE: To evaluate the accuracy of home blood glucose meters during hypoglycemia.
METHODS: Six blood glucose meters-One Touch II (LifeScan, Milpitas, CA), Companion II (Medisense, Cambridge, U.K.), Reflolux (Boehringer Mannheim, Mannheim, Germany), Accutrend (Boehringer Mannheim), Elite (Bayer, Munich, Germany), and HemoCue (HemoCue, Angelholm, Sweden)-were compared with a reference method (Beckman Glucose Analyzer 2). Glucose concentrations from arterialized venous blood samples were measured using all glucose meters (whole blood) and the reference method (plasma) during hypoglycemic-hyperinsulinemic clamps in 15 subjects.
RESULTS: In total, 663 blood glucose monitor readings and 119 reference values ranging from 2.28 to 3.89 mmol/l were analyzed. The correlation coefficients and the percentage of measurements within 20% and outside 40% of the reference values for each glucose meter were as follows: One Touch II: 0.91, 99.2% and 0%; Companion II: 0.81, 88.2% and 2.5%; Reflolux: 0.78, 85.0% and 0.9%; Accutrend: 0.88, 46.0% and 6.6%; Elite: 0.78, 75.6% and 4.2%; and HemoCue: 0.93, 96.6% and 0% (P < 0.001).
CONCLUSIONS: There were substantial differences between the blood glucose meters during hypoglycemia, and none of the devices met the latest criteria recommended by the American Diabetes Association.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8941473     DOI: 10.2337/diacare.19.12.1412

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  9 in total

1.  Statistical approach of assessing the reliability of glucose sensors: the GLYCENSIT procedure.

Authors:  Tom Van Herpe; Kristiaan Pelckmans; Jos De Brabanter; Frizo Janssens; Bart De Moor; Greet Van den Berghe
Journal:  J Diabetes Sci Technol       Date:  2008-11

2.  Analytical performance of glucose monitoring systems at different blood glucose ranges and analysis of outliers in a clinical setting.

Authors:  Christoph Hasslacher; Felix Kulozik; Isabel Platten
Journal:  J Diabetes Sci Technol       Date:  2014-02-18

3.  Analysis article on the performance analysis of the OneTouch UltraVue blood glucose monitoring system.

Authors:  Bogdan Solnica
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

4.  Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin.

Authors:  D W Schmidtke; A C Freeland; A Heller; R T Bonnecaze
Journal:  Proc Natl Acad Sci U S A       Date:  1998-01-06       Impact factor: 11.205

5.  FreeStyle Mini blood glucose results are accurate and suitable for use in glycemic clamp protocols.

Authors:  Ohad Cohen; Sigal Shaklai; Ephraim Gabis; Michael A Pani
Journal:  J Diabetes Sci Technol       Date:  2008-09

6.  Evaluation of "point of care" devices in the measurement of low blood glucose in neonatal practice.

Authors:  H T Ho; W K Y Yeung; B W Y Young
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2004-07       Impact factor: 5.747

7.  Inaccuracy of Venous Point-of-Care Glucose Measurements in Critically Ill Patients: A Cross-Sectional Study.

Authors:  Adriano José Pereira; Thiago Domingos Corrêa; Francisca Pereira de Almeida; Rodrigo Octávio Deliberato; Michelle dos Santos Lobato; Nelson Akamine; Eliézer Silva; Alexandre Biasi Cavalcanti
Journal:  PLoS One       Date:  2015-06-12       Impact factor: 3.240

8.  Frontal lobe regulation of blood glucose levels: support for the limited capacity model in hostile violence-prone men.

Authors:  Robert P Walters; Patti Kelly Harrison; Ransom W Campbell; David W Harrison
Journal:  Brain Inform       Date:  2016-02-01

Review 9.  Challenges in hyperglycemia management in critically ill patients with COVID-19.

Authors:  Rajesh Kethireddy; Darshan Gandhi; Asim Kichloo; Love Patel
Journal:  World J Crit Care Med       Date:  2022-07-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.