Analysis article on the performance analysis of the OneTouch UltraVue blood glucose monitoring system.

Bogdan Solnica1.   

Abstract

In this issue of Journal of Diabetes Science and Technology, Chang and colleagues present the analytical performance evaluation of the OneTouch UltraVue blood glucose meter. This device is an advanced construction with a color display, used-strip ejector, no-button interface, and short assay time. Accuracy studies were performed using a YSI 2300 analyzer, considered the reference. Altogether, 349 pairs of results covering a wide range of blood glucose concentrations were analyzed. Patients with diabetes performed a significant part of the tests. Obtained results indicate good accuracy of OneTouch UltraVue blood glucose monitoring system, satisfying the International Organization for Standardization recommendations and thereby locating >95% of tests within zone A of the error grid. Results of the precision studies indicate good reproducibility of measurements. In conclusion, the evaluation of the OneTouch UltraVue meter revealed good analytical performance together with convenient handling useful for self-monitoring of blood glucose performed by elderly diabetes patients. 2009 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20144432      PMCID: PMC2769915          DOI: 10.1177/193229680900300522

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  7 in total

1.  Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing.

Authors:  Z Tang; J H Lee; R F Louie; G J Kost
Journal:  Arch Pathol Lab Med       Date:  2000-08       Impact factor: 5.534

2.  Improving results from home blood-glucose monitoring: accuracy and reliability require greater patient education as well as improved technology.

Authors:  Malcolm Nattrass
Journal:  Clin Chem       Date:  2002-07       Impact factor: 8.327

3.  Standardized evaluation of instruments for self-monitoring of blood glucose by patients and a technologist.

Authors:  Gunn B B Kristensen; Kari Nerhus; Geir Thue; Sverre Sandberg
Journal:  Clin Chem       Date:  2004-06       Impact factor: 8.327

4.  Between-lot variation in external quality assessment of glucose: clinical importance and effect on participant performance evaluation.

Authors:  Gunn B B Kristensen; Nina Gade Christensen; Geir Thue; Sverre Sandberg
Journal:  Clin Chem       Date:  2005-09       Impact factor: 8.327

5.  Performance analysis of the OneTouch UltraVue blood glucose monitoring system.

Authors:  Anna Chang; Alice Orth; Bryan Le; Perla Menchavez; Lupe Miller
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

6.  Accuracy of home blood glucose meters during hypoglycemia.

Authors:  Z Trajanoski; G A Brunner; R J Gfrerer; P Wach; T R Pieber
Journal:  Diabetes Care       Date:  1996-12       Impact factor: 19.112

7.  Analytical evaluation of the Optium Xido blood glucose meter.

Authors:  Bogdan Solnica; Jerzy Naskalski; Wojciech Gernand
Journal:  Clin Chem Lab Med       Date:  2008       Impact factor: 3.694

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.