Literature DB >> 8893782

Tensile properties of the interosseous membrane of the human forearm.

H J Pfaeffle1, M M Tomaino, R Grewal, J Xu, N D Boardman, S L Woo, J H Herndon.   

Abstract

The interosseous membrane is a structure deep in the forearm that joins the radius and the ulna. It is made up of membranous and ligamentous regions. Two main ligamentous structures have been described: a prominent central fiber group, the "central band," and a smaller proximal fibrous band, the "oblique cord." Many authors believe that the central band plays a biomechanical role in the normal and fractured forearm and that it may function much like a ligament. The objective of this study was to determine the tensile properties of the central band. Eighteen fresh frozen forearms from cadavers (45-70 years of age, both sexes) were used. A fiber bundle of the central band was subjected to a uniaxial tensile test to failure in a materials testing machine, and its tensile properties were calculated. Stiffness, ultimate load, and energy absorbed to failure were expressed as a function of specimen width. The central band structure had a stiffness of 13.1 +/- 3.0 N/mm per mm width and an ultimate load of 56.6 +/- 15.1 N per mm width (mean +/- SD). The tissue of the central band displayed a modulus of 608.1 +/- 160.2 MPa, ultimate tensile strength of 45.1 +/- 10.3 MPa, and strain at failure of 9.0 +/- 2.0%. This study demonstrated that the central band is comprised of strong tissue. The material properties of the central band compare with those of patellar tendon: modulus is 120% and ultimate tensile strength is 84% that of patellar tendon. As a structure, the interosseous membrane is stiff and capable of bearing high loads. Although load distribution across the central band is unknown, a 1.7 cm wide, evenly loaded homogenous portion of the central band would possess a stiffness comparable with that of the anterior cruciate ligament. The results of this study provide a basis for future analyses of radioulnar stability and load transfer.

Entities:  

Mesh:

Year:  1996        PMID: 8893782     DOI: 10.1002/jor.1100140525

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  12 in total

1.  Ligamentoplasty of the forearm interosseous membrane using the semitendinosus tendon: anatomical study and surgical procedure.

Authors:  M Soubeyrand; C Oberlin; C Dumontier; Z Belkheyar; C Lafont; R Degeorges
Journal:  Surg Radiol Anat       Date:  2006-02-11       Impact factor: 1.246

2.  A numerical study on stress distribution across the ankle joint: Effects of material distribution of bone, muscle force and ligaments.

Authors:  Subrata Mondal; Rajesh Ghosh
Journal:  J Orthop       Date:  2017-05-17

3.  Effects of inferior tibiofibular syndesmosis injury and screw stabilization on motion of the ankle: a finite element study.

Authors:  Qinghua Liu; Guanghui Zhao; Bin Yu; Jianbin Ma; Zhong Li; Kun Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-19       Impact factor: 4.342

Review 4.  Role of the interosseous membrane in post-traumatic forearm instability: instructional review.

Authors:  Uros Meglic; Noemi Szakacs; Margherita Menozzi; Raul Barco; Eduard Alentorn-Geli; Alessandra Colozza
Journal:  Int Orthop       Date:  2021-07-31       Impact factor: 3.075

5.  Biomechanical features of six design of the delta external fixator for treating Pilon fracture: a finite element study.

Authors:  Muhammad Hanif Ramlee; Mohd Ayub Sulong; Evelyn Garcia-Nieto; Daniel Angure Penaranda; Antonio Ros Felip; Mohammed Rafiq Abdul Kadir
Journal:  Med Biol Eng Comput       Date:  2018-04-21       Impact factor: 2.602

6.  Biomechanical behavior of human crural fascia in anterior and posterior regions of the lower limb.

Authors:  Piero G Pavan; Paola Pachera; Carla Stecco; Arturo N Natali
Journal:  Med Biol Eng Comput       Date:  2015-05-16       Impact factor: 2.602

7.  Non-contact strain measurement in the mouse forearm loading model using digital image correlation (DIC).

Authors:  Mark T Begonia; Mark Dallas; Bruno Vizcarra; Ying Liu; Mark L Johnson; Ganesh Thiagarajan
Journal:  Bone       Date:  2015-09-24       Impact factor: 4.398

8.  Experimental and finite element analysis of dynamic loading of the mouse forearm.

Authors:  Ganesh Thiagarajan; Yunkai Lu; Mark Dallas; Mark L Johnson
Journal:  J Orthop Res       Date:  2014-09-05       Impact factor: 3.494

9.  Analysis of the stress and displacement distribution of inferior tibiofibular syndesmosis injuries repaired with screw fixation: a finite element study.

Authors:  Qinghua Liu; Kun Zhang; Yan Zhuang; Zhong Li; Bin Yu; Guoxian Pei
Journal:  PLoS One       Date:  2013-12-03       Impact factor: 3.240

10.  Digitalization of the IOM: A comprehensive cadaveric study for obtaining three-dimensional models and morphological properties of the forearm's interosseous membrane.

Authors:  Fabio Carrillo; Simon Suter; Fabio A Casari; Reto Sutter; Ladislav Nagy; Jess G Snedeker; Philipp Fürnstahl
Journal:  Sci Rep       Date:  2020-04-14       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.