Literature DB >> 27818521

A New Differential Pressure Flow Meter for Measurement of Human Breath Flow: Simulation and Experimental Investigation.

Devon Bridgeman1, Francis Tsow1, Xiaojun Xian1, Erica Forzani1.   

Abstract

The development and performance characterization of a new differential pressure-based flow meter for human breath measurements is presented in this article. The device, called a "Confined Pitot Tube," is comprised of a pipe with an elliptically shaped expansion cavity located in the pipe center, and an elliptical disk inside the expansion cavity. The elliptical disk, named Pitot Tube, is exchangeable, and has different diameters, which are smaller than the diameter of the elliptical cavity. The gap between the disk and the cavity allows the flow of human breath to pass through. The disk causes an obstruction in the flow inside the pipe, but the elliptical cavity provides an expansion for the flow to circulate around the disk, decreasing the overall flow resistance. We characterize the new sensor flow experimentally and theoretically, using Comsol Multiphysics® software with laminar and turbulent models. We also validate the sensor, using inhalation and exhalation tests and a reference method.

Entities:  

Keywords:  biomedical engineering; computational fluid dynamics; fluid mechanics; transport; turbulence

Year:  2016        PMID: 27818521      PMCID: PMC5091841          DOI: 10.1002/aic.15143

Source DB:  PubMed          Journal:  AIChE J        ISSN: 0001-1541            Impact factor:   3.993


  10 in total

1.  Trace composition of human respiratory gas.

Authors:  J P Conkle; B J Camp; B E Welch
Journal:  Arch Environ Health       Date:  1975-06

2.  Evaluation of a hot-wire respiratory flowmeter for clinical applicability.

Authors:  I Yoshiya; Y Shimada; K Tanaka
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1979-11

3.  A pocket-sized metabolic analyzer for assessment of resting energy expenditure.

Authors:  Di Zhao; Xiaojun Xian; Mirna Terrera; Ranganath Krishnan; Dylan Miller; Devon Bridgeman; Kevin Tao; Lihua Zhang; Francis Tsow; Erica S Forzani; Nongjian Tao
Journal:  Clin Nutr       Date:  2013-06-10       Impact factor: 7.324

Review 4.  Chemical sensors for breath gas analysis: the latest developments at the Breath Analysis Summit 2013.

Authors:  Ulrike Tisch; Hossam Haick
Journal:  J Breath Res       Date:  2014-03-28       Impact factor: 3.262

5.  A mathematical model for the ultrasonic measurement of respiratory flow.

Authors:  W Blumenfeld; P D Wilson; S Turney
Journal:  Med Biol Eng       Date:  1974-09

6.  Acceptable levels for breathing resistance of respiratory apparatus.

Authors:  R A Bentley; O G Griffin; R G Love; D C Muir; K F Sweetland
Journal:  Arch Environ Health       Date:  1973-10

7.  The accuracy of pneumotachograph measurements during mechanical ventilation.

Authors:  J W Kreit; F C Sciurba
Journal:  Am J Respir Crit Care Med       Date:  1996-10       Impact factor: 21.405

8.  Evaluation of five small turbine-type respirometers used in adult anesthesia.

Authors:  A H Ilsley; J D Hart; R T Withers; J G Roberts
Journal:  J Clin Monit       Date:  1993-07

9.  Turbine flowmeter vs. Fleisch pneumotachometer: a comparative study for exercise testing.

Authors:  M P Yeh; T D Adams; R M Gardner; F G Yanowitz
Journal:  J Appl Physiol (1985)       Date:  1987-09

Review 10.  Indirect calorimetry: a practical guide for clinicians.

Authors:  Heather A Haugen; Lingtak-Neander Chan; Fanny Li
Journal:  Nutr Clin Pract       Date:  2007-08       Impact factor: 3.080

  10 in total
  1 in total

1.  Wearable Piezoelectric Airflow Transducers for Human Respiratory and Metabolic Monitoring.

Authors:  Lu Jin; Zekun Liu; Mucahit Altintas; Yan Zheng; Zhangchi Liu; Sirui Yao; Yangyang Fan; Yi Li
Journal:  ACS Sens       Date:  2022-07-22       Impact factor: 9.618

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.