[4-7 year results of total hip arthroplasty with special reference to late complications].

S Maier, P Griss, T Rahmfeld, T Dinkelacker.   

Abstract

The 4-7 year results of total hip arthroplasty (95 hips, McKee-Müller and Charnley-Müller) are presented in detail both from a clinical and radiological point of view. About 83% of the hips showed a good and excellent clinical condition at the time of reevaluation. Deep infection was observed in 4.2% of the hips, 11.2% of the hips had already been reoperated at the time of reevaluation because of aseptic loosening of one or both components. Another 3.5% of the hips showed clinical and radiological evidence of aseptic loosening, some more 4.9% of the hips had radiological evidence of loosening without clinical signs at the time of reevaluation. Furthermore, 6.8% of the hips had radiological evidence of third degree periarticular calcification influencing the clinical state of the hip in a negative manner. Over all serious complications which gave or will give rise to reoperation were 30.6%. The causes for serious complications are discussed extensively. It is proposed to restrict indication for total hip arthroplasty and to reemphasize hip-conserving procedures more seriously.

Entities:  

Mesh:

Year:  1977        PMID: 888513

Source DB:  PubMed          Journal:  Z Orthop Ihre Grenzgeb        ISSN: 0044-3220


  7 in total

1.  Computer-aided manufacture of individual endoprostheses. Preliminary communication.

Authors:  G Aldinger; A Fischer; B Kurtz
Journal:  Arch Orthop Trauma Surg       Date:  1983

2.  Failures of total hip arthroplasty and probable incidence of revision surgery in the future. Calculations according to a mathematical model based on a ten years' experience in total hip arthroplasty.

Authors:  E Morscher; A Schmassmann
Journal:  Arch Orthop Trauma Surg       Date:  1983

3.  [Comparative experimental investigations with bioglass (L. L. Hench) and Al2O3-ceramic coated with mod. bioglass. II. Results of experiments with loaded implants (author's transl)].

Authors:  P Griss; E Werner; G Heimke; U Raute-Krenisen
Journal:  Arch Orthop Trauma Surg       Date:  1978-08-30

4.  [What is the significance of calcar resorption after total hip replacement (author's transl)].

Authors:  P Griss; G Heimke; E Werner; J Bleicher; G Jentschura
Journal:  Arch Orthop Trauma Surg       Date:  1978-10-27

5.  Results of endoprosthetic hip joint replacement with the aluminum ceramic-metal composite prosthesis "Lindenhof".

Authors:  D Stock; E D Diezemann; J Gottstein
Journal:  Arch Orthop Trauma Surg       Date:  1980

6.  Clinical experience with Mueller total hip endoprostheses of different design and material.

Authors:  H G Willert; U Buchhorn; L Zichner
Journal:  Arch Orthop Trauma Surg       Date:  1980

Review 7.  Results of alloarthroplasty of the hip joint.

Authors:  W Oberthaler; R Bauer; K Sattler
Journal:  Arch Orthop Trauma Surg       Date:  1980