Literature DB >> 7447669

Clinical experience with Mueller total hip endoprostheses of different design and material.

H G Willert, U Buchhorn, L Zichner.   

Abstract

Patients of the Orthopaedic University Hospital in Frankfurt operated between 1970 and 1977 were examined to control the success of implantations of total hip endoprostheses. Ninety-three percent of totally 1497 implanted hip prostheses are Müller standard type, additionally there have been implanted 44 Weber-Huggler prostheses and 54 special long stem prostheses. During the follow-up period of 10 years 7.4% of the primarily implanted prostheses had to be revised. The reasons for revision were loosening of the stem and/or socket in 56% of the cases, 20% infections, 14% technical errors and in 11% of the cases fractures of the stem occured. Fifty-two percent of the implanted Weber-Huggler prostheses with rotational ball heads made of polyester had to be revised in the meantime, 78% of the cases because of loosening of the prosthetic components. It could be shown that the number of infected cases could be diminished after introduction of an ultraclean air operating box. The change of the cross section of the Müller-type-stem from a round medial wedge to a flat one and the introduction of CoNiCrMo wrought alloy Protasul-10 instead of CoCrMo cast alloy Protasul-2 as stem material in 1973 resulted in a much smaller rate of loosened prostheses without fractures of the forged Protasul-10 stems. During the 6 examined years there has been no fracture of a prosthetic stem made of Protasul-10.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7447669     DOI: 10.1007/bf00389727

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  15 in total

1.  MP35N: a corrosion resistant, high strength alloy for orthopedic surgical impants: bio-assay results.

Authors:  F Escalas; J Galante; W Rostoker; P H Coogan
Journal:  J Biomed Mater Res       Date:  1975-05

2.  [Results of the total hip replacement operations (author's transl)].

Authors:  H Stock; H Rösch; H P Dumpert; W Beck
Journal:  Arch Orthop Unfallchir       Date:  1975-06-27

3.  Metallurgical and clinical experience with cast and forged cobalt/chromium base implant metals of compound construction for artificial joint endoprostheses.

Authors:  M Semlitsch
Journal:  Reconstr Surg Traumatol       Date:  1976

4.  [4-7 year results of total hip arthroplasty with special reference to late complications].

Authors:  S Maier; P Griss; T Rahmfeld; T Dinkelacker
Journal:  Z Orthop Ihre Grenzgeb       Date:  1977-06

5.  [Complications after total hip replacement (author's transl)].

Authors:  K P Schulitz; H O Dustmann
Journal:  Arch Orthop Unfallchir       Date:  1976-06-18

6.  [Results of total hip replacement (control of the 1962--1968 operated cases)].

Authors:  R Safi; A Schreiber
Journal:  Z Orthop Ihre Grenzgeb       Date:  1972-02

7.  [Experience with poly-ester as a component of the rotation total prosthesis for the hip-joint (author's transl)].

Authors:  B G Weber; G Stühmer; M Semlitsch
Journal:  Z Orthop Ihre Grenzgeb       Date:  1974-10

8.  The long-term results of low-friction arthroplasty of the hip performed as a primary intervention.

Authors:  J Charnley
Journal:  J Bone Joint Surg Br       Date:  1972-02

9.  [Clinical relevance of signs of looseness in a hip prosthesis].

Authors:  U Buchhorn; P Griss; P G Niederer; H G Willert
Journal:  Z Orthop Ihre Grenzgeb       Date:  1979-08

10.  [Further experiences with total hip arthroplasty. Clinical and roentgenographic results after 3--6 years following implantation (author's transl)].

Authors:  M H Hackenbroch; H Bruns; R Holbe; H Lechleuthner
Journal:  Arch Orthop Unfallchir       Date:  1976-03-26
View more
  2 in total

1.  Long-term results and survivorship of the McKee-Farrar total hip prosthesis.

Authors:  T Visuri
Journal:  Arch Orthop Trauma Surg       Date:  1987

2.  Granulomatous pseudotumors in total joint replacement.

Authors:  H J Griffiths; J Burke; T A Bonfiglio
Journal:  Skeletal Radiol       Date:  1987       Impact factor: 2.199

  2 in total