Literature DB >> 17581942

Relevance of routine use of the anaerobic blood culture bottle.

Patrick Grohs1, Jean-Luc Mainardi, Isabelle Podglajen, Xavier Hanras, C Eckert, A Buu-Hoï, E Varon, Laurent Gutmann.   

Abstract

Using the BacT/Alert automated system, we conducted a 1-year retrospective study on blood cultures, focusing on the relevance of routine use of the anaerobic bottle. The rate of patients with positive blood cultures was 19.7%. Among these, 13.5% had a positive anaerobic bottle in the absence of any aerobic bottle, and 2/3 of these grew with nonobligate anaerobes. These patients were hospitalized in 20 out of 26 wards of the hospital group. For 65.4% of the monomicrobial-positive blood cultures growing Enterobacteriaceae, the anaerobic bottle detected growth earlier than the corresponding aerobic bottle. These data suggest that, in our institution, the use of an anaerobic bottle is still relevant.

Entities:  

Mesh:

Year:  2007        PMID: 17581942      PMCID: PMC1951263          DOI: 10.1128/JCM.00059-07

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  21 in total

1.  Comité de l'Antibiogramme de la Société Française de Microbiologie report 2003.

Authors: 
Journal:  Int J Antimicrob Agents       Date:  2003-04       Impact factor: 5.283

2.  Evaluation of a plastic nonvented aerobic blood culture bottle for use with the BacT/ALERT microbial detection system.

Authors:  J W Snyder; G K Munier; G D Bostic; P S Bozigar; R Hanna
Journal:  J Clin Microbiol       Date:  2002-12       Impact factor: 5.948

3.  What is the relevance of obtaining multiple blood samples for culture? A comprehensive model to optimize the strategy for diagnosing bacteremia.

Authors:  Brigitte Lamy; Pascal Roy; Gérard Carret; Jean-Pierre Flandrois; Marie Laure Delignette-Muller
Journal:  Clin Infect Dis       Date:  2002-09-10       Impact factor: 9.079

4.  Optimal testing parameters for blood cultures.

Authors:  F R Cockerill; J W Wilson; E A Vetter; K M Goodman; C A Torgerson; W S Harmsen; C D Schleck; D M Ilstrup; J A Washington; W R Wilson
Journal:  Clin Infect Dis       Date:  2004-05-25       Impact factor: 9.079

5.  BacT/Alert: an automated colorimetric microbial detection system.

Authors:  T C Thorpe; M L Wilson; J E Turner; J L DiGuiseppi; M Willert; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

6.  Anaerobic bacteremia: declining rate over a 15-year period.

Authors:  W R Gransden; S J Eykyn; I Phillips
Journal:  Rev Infect Dis       Date:  1991 Nov-Dec

7.  Reassessment of the routine anaerobic culture and incubation time in the BacT/Alert FAN blood culture bottles.

Authors:  N Cornish; B A Kirkley; K A Easley; J A Washington
Journal:  Diagn Microbiol Infect Dis       Date:  1999-10       Impact factor: 2.803

8.  Critical assessment of blood culture techniques: analysis of recovery of obligate and facultative anaerobes, strict aerobic bacteria, and fungi in aerobic and anaerobic blood culture bottles.

Authors:  P R Murray; P Traynor; D Hopson
Journal:  J Clin Microbiol       Date:  1992-06       Impact factor: 5.948

9.  Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

Authors:  M L Wilson; M P Weinstein; L G Reimer; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1992-02       Impact factor: 5.948

10.  Reemergence of anaerobic bacteremia.

Authors:  Britta Lassmann; Daniel R Gustafson; Christina M Wood; Jon E Rosenblatt
Journal:  Clin Infect Dis       Date:  2007-02-14       Impact factor: 9.079

View more
  14 in total

1.  Optimized pathogen detection with 30- compared to 20-milliliter blood culture draws.

Authors:  Robin Patel; Emily A Vetter; W Scott Harmsen; Cathy D Schleck; Hind J Fadel; Franklin R Cockerill
Journal:  J Clin Microbiol       Date:  2011-10-05       Impact factor: 5.948

2.  Evaluation of the alkaline wash/lysis procedure for the molecular diagnosis of a positive bacterial blood culture in clinical routine practice.

Authors:  Sheng-Chuan Hsi; Jun-Ren Sun; Tzong-Shi Chiueh
Journal:  J Clin Lab Anal       Date:  2010       Impact factor: 2.352

3.  Appropriateness of blood culture testing parameters in routine practice. Results from a cross-sectional study.

Authors:  V Vitrat-Hincky; P François; J Labarère; C Recule; J P Stahl; P Pavese
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2010-11-18       Impact factor: 3.267

4.  Are incidence and epidemiology of anaerobic bacteremia really changing?

Authors:  A Vena; P Muñoz; L Alcalá; A Fernandez-Cruz; C Sanchez; M Valerio; E Bouza
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2015-05-28       Impact factor: 3.267

5.  Evaluation of an intervention to improve blood culture practices: a cluster randomised trial.

Authors:  P Pavese; M Maillet; V Vitrat-Hincky; C Recule; J-P Vittoz; A Guyomard; A Seigneurin; P François
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2014-07-02       Impact factor: 3.267

6.  Effect of Clinically Meaningful Antibiotic Concentrations on Recovery of Escherichia coli and Klebsiella pneumoniae Isolates from Anaerobic Blood Culture Bottles with and without Antibiotic Binding Resins.

Authors:  Iris H Chen; David P Nicolau; Joseph L Kuti
Journal:  J Clin Microbiol       Date:  2019-11-22       Impact factor: 5.948

7.  The Addition of Anaerobic Blood Cultures for Pediatric Patients with Concerns for Bloodstream Infections: Prevalence and Time to Positive Cultures.

Authors:  Jennifer Dien Bard; Todd P Chang; Rebecca Yee; Keya Manshadi; Nhan Lichtenfeld; Hee Jae Choi; Ara Festekjian
Journal:  J Clin Microbiol       Date:  2020-08-24       Impact factor: 5.948

8.  Predominance of Enterobacteriaceae isolates in early positive anaerobic blood culture bottles in BacT/Alert system.

Authors:  Tzong-Shi Chiueh; Shih-Yi Lee; Sheng-Hui Tang; Jang-Jih Lu; Jun-Ren Sun
Journal:  J Clin Lab Anal       Date:  2013-01-24       Impact factor: 2.352

9.  Performance of two resin-containing blood culture media in detection of bloodstream infections and in direct matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) broth assays for isolate identification: clinical comparison of the BacT/Alert Plus and Bactec Plus systems.

Authors:  Barbara Fiori; Tiziana D'Inzeo; Viviana Di Florio; Flavio De Maio; Giulia De Angelis; Alessia Giaquinto; Lara Campana; Eloisa Tanzarella; Mario Tumbarello; Massimo Antonelli; Maurizio Sanguinetti; Teresa Spanu
Journal:  J Clin Microbiol       Date:  2014-07-16       Impact factor: 5.948

10.  The Performance of the Four Anaerobic Blood Culture Bottles BacT/ALERT-FN, -FN Plus, BACTEC-Plus and -Lytic in Detection of Anaerobic Bacteria and Identification by Direct MALDI-TOF MS.

Authors:  Mohammed Almuhayawi; Osman Altun; Adam Dilshad Abdulmajeed; Måns Ullberg; Volkan Özenci
Journal:  PLoS One       Date:  2015-11-10       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.