Literature DB >> 8775707

Measuring stability of wire cerclage in femoral fractures when performing total hip replacement. In vitro study on a standardized bone model.

M Wagner1, F Knorr-Held, D Hohmann.   

Abstract

The stability of wire cerclage was investigated on a wooden model. Two semitubular shells made of hard oak were firmly joined together using cerclage wires of different diameters and with different techniques. A conical test piece was then implanted. The test set-up was subjected once to an axial force of 4 kN and a torque of 20 Nm using a testing machine. Implant excursion at the interface was measured. One hundred forty measurements carried out on test pieces with fissures demonstrated that cerclage wires with the largest diameter possible should be used with a double-loop technique. Wire diameters under 1.2 mm are unsuitable for cerclage of the femur because they rupture easily. The most stable cerclage is obtained with two double cerclages using 1.5-mm stainless steel wires. Although micromotion is greater than for the reference group without fissures, no cases of excursions exceeding 100 microns could be measured. In comparison with a femoral shaft that is not fractured, marked instability remains. It is recommended that a tightening tool be used to tighten the wires, as this achieves considerably more stable cerclage than that achieved with two forceps.

Entities:  

Mesh:

Year:  1996        PMID: 8775707     DOI: 10.1007/bf00453214

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  13 in total

1.  FRACTURE OF THE FEMUR FOLLOWING PROSTHETIC ARTHROPLASTY OF THE HIP. REPORT OF NINE CASES.

Authors:  T F PARRISH; J R JONES
Journal:  J Bone Joint Surg Am       Date:  1964-03       Impact factor: 5.284

2.  Femoral fractures in conjunction with total hip replacement.

Authors:  R D Scott; R H Turner; S M Leitzes; O E Aufranc
Journal:  J Bone Joint Surg Am       Date:  1975-06       Impact factor: 5.284

3.  Management of intraoperative femur fractures associated with revision hip arthroplasty.

Authors:  C M Christensen; B M Seger; R B Schultz
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

4.  Observations on the effect of movement on bone ingrowth into porous-surfaced implants.

Authors:  R M Pilliar; J M Lee; C Maniatopoulos
Journal:  Clin Orthop Relat Res       Date:  1986-07       Impact factor: 4.176

5.  [Femur revision prosthesis].

Authors:  H Wagner; M Wagner
Journal:  Z Orthop Ihre Grenzgeb       Date:  1993 Nov-Dec

6.  [Biomechanics of wire cerclage].

Authors:  H Mittelmeier; U Hanser
Journal:  Z Orthop Ihre Grenzgeb       Date:  1979-08

7.  Intraoperative femur fractures during total hip replacement.

Authors:  M M Taylor; M H Meyers; J P Harvey
Journal:  Clin Orthop Relat Res       Date:  1978 Nov-Dec       Impact factor: 4.176

8.  Fractures of the femur during total hip replacement and their management.

Authors:  M A Khan; M O'Driscoll
Journal:  J Bone Joint Surg Br       Date:  1977-02

Review 9.  Cementless total hip arthroplasty.

Authors:  E W Morscher
Journal:  Clin Orthop Relat Res       Date:  1983-12       Impact factor: 4.176

10.  Prophylactic cerclage: a method of preventing femur fracture in uncemented total hip arthroplasty.

Authors:  P J Herzwurm; J Walsh; K A Pettine; F R Ebert
Journal:  Orthopedics       Date:  1992-02       Impact factor: 1.390

View more
  4 in total

1.  Biomechanical performance of different cable and wire cerclage configurations.

Authors:  Mark Lenz; Stephan Marcel Perren; Robert Geoff Richards; Thomas Mückley; Gunther Olaf Hofmann; Boyko Gueorguiev; Markus Windolf
Journal:  Int Orthop       Date:  2012-11-10       Impact factor: 3.075

Review 2.  [Periprosthetic fractures after total hip arthroplasty : classification, diagnosis and therapy strategies].

Authors:  B M Holzapfel; P M Prodinger; M Hoberg; R Meffert; M Rudert; R Gradinger
Journal:  Orthopade       Date:  2010-05       Impact factor: 1.087

3.  Comparing the In Vitro Stiffness of Straight-DCP, Wave-DCP, and LCP Bone Plates for Femoral Osteosynthesis.

Authors:  José Ricardo Lenzi Mariolani; William Dias Belangero
Journal:  ISRN Orthop       Date:  2013-02-26

4.  Femur Strength is Similar Before and After Iatrogenic Fracture During Total Hip Arthroplasty: A Biomechanical Analysis.

Authors:  Bailey J Ross; Akshar H Patel; J Heath Wilder; John M Weldy; Charles S Dranoff; Matthew J Weintraub; Nathan E Kim; Hao Wang; William F Sherman
Journal:  Arthroplast Today       Date:  2022-04-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.