Literature DB >> 8748287

Comparative evaluation of BACTEC aerobic Plus/F and Septi-Chek Release blood culture media.

P Rohner1, B Pepey, R Auckenthaler.   

Abstract

The BACTEC 9240 (Becton Dickinson, Sparks, Md.) automated blood culture system is based on the continuous monitoring of CO2 production by means of a fluorescent sensor attached to the bottom of culture vials. We compared the performance of the BACTEC aerobic Plus/F medium to that of the Septi-Chek Release medium (Becton Dickinson, Sparks, Md.), a manual biphasic blood culture system. Sets consisting of BACTEC aerobic Plus/F and Septi-Chek Release vials inoculated with similar volumes (7 +/- 2 ml) were evaluated. In the laboratory, systems were equipped and analyzed according to the manufacturer's recommendations. The BACTEC and Septi-Chek vials were incubated at 35 degrees C for 5 days. A total of 6,116 compliant sets were obtained from 1,972 adult patients (3.1 cultures per patient). Of these, 731 (12%) were culture positive, including 612 (10%) that yielded at least one pathogen, and 143 (2%) were considered to be contaminated. Of the 672 pathogenic organisms detected, 524 were isolated from the BACTEC aerobic Plus/F medium and 574 were isolated from the Septi-Chek Release medium, 428 organisms grew in both media, 96 organisms grew only in the BACTEC aerobic Plus/F medium, and 146 organisms grew only in the Septi-Chek Release medium (P = 0.001). Haemophilus spp. were isolated more often (P = 0.03) from the BACTEC aerobic Plus/F medium; however, more Streptococcus anginosus organisms (P = 0.02), members of the Enterobacteriaceae family (P < 0.03), and gram-negative anaerobes (P = 0.03) were isolated from the Septi-Chek Release medium. Pathogenic organisms were detected significantly earlier (P < 0.0001) with the BACTEC aerobic Plus/F medium in conjunction with the BACTEC 9240 instrument than with the Septi-Chek Release medium.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8748287      PMCID: PMC228744          DOI: 10.1128/jcm.34.1.126-129.1996

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  8 in total

1.  Evaluation of the new improved BHI-lysis blood culture medium for the BCB Roche system.

Authors:  P Rohner; H Burkardt; H Dreismann; R Auckenthaler
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1991-08       Impact factor: 3.267

2.  Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles.

Authors:  M P Weinstein; S Mirrett; M L Wilson; L J Harrell; C W Stratton; L B Reller
Journal:  J Clin Microbiol       Date:  1991-05       Impact factor: 5.948

3.  Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia.

Authors:  M P Weinstein; S Mirrett; L G Reimer; M L Wilson; S Smith-Elekes; C R Chuard; K L Joho; L B Reller
Journal:  J Clin Microbiol       Date:  1995-04       Impact factor: 5.948

4.  Multicenter clinical evaluation of a continuous monitoring blood culture system using fluorescent-sensor technology (BACTEC 9240).

Authors:  F S Nolte; J M Williams; R C Jerris; J A Morello; C D Leitch; S Matushek; L D Schwabe; F Dorigan; F E Kocka
Journal:  J Clin Microbiol       Date:  1993-03       Impact factor: 5.948

5.  Comparison of BacT/Alert with Signal blood culture system.

Authors:  P Rohner; B Pepey; R Auckenthaler
Journal:  J Clin Microbiol       Date:  1995-02       Impact factor: 5.948

6.  Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

Authors:  M L Wilson; M P Weinstein; L G Reimer; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1992-02       Impact factor: 5.948

7.  Multicenter comparison of the high volume (10 ml) NR BACTEC PLUS system and the standard (5 ml) NR BACTEC system.

Authors:  F P Koontz; K K Flint; J K Reynolds; S D Allen
Journal:  Diagn Microbiol Infect Dis       Date:  1991 Mar-Apr       Impact factor: 2.803

8.  Detection of positive blood cultures by the Bactec NR660. The clinical importance of five versus seven days of testing.

Authors:  K C Masterson; J E McGowan
Journal:  Am J Clin Pathol       Date:  1988-07       Impact factor: 2.493

  8 in total
  9 in total

Review 1.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

2.  Performance of a new combination of blood culture vials in sepsis detection: a 2-year retrospective comparison.

Authors:  Paolo Bottino; Fabio Rapallo; Elisa Gamalero; Andrea Rocchetti
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2019-05-08       Impact factor: 3.267

3.  Advantage of combining resin with lytic BACTEC blood culture media.

Authors:  P Rohner; B Pepey; R Auckenthaler
Journal:  J Clin Microbiol       Date:  1997-10       Impact factor: 5.948

4.  Controlled comparative evaluation of BacT/Alert FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia.

Authors:  G V Doern; A Barton; S Rao
Journal:  J Clin Microbiol       Date:  1998-09       Impact factor: 5.948

5.  Improved recovery of antibiotic-stressed microorganisms on inclusion of saponin in aerobic blood culture media.

Authors:  T S Elliott; C M Stevens; F Macrae; I T Hart; D E Healing; M Palmer; C R Catchpole
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1998-08       Impact factor: 3.267

6.  Use of simulated blood cultures to compare a specific fungal medium with a standard microorganism medium for yeast detection.

Authors:  H Fricker-Hidalgo; F Chazot; B Lebeau; H Pelloux; P Ambroise-Thomas; R Grillot
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1998-02       Impact factor: 3.267

7.  Comparison of the BacT/Alert FAN aerobic and the Difco ESP 80A aerobic bottles for pediatric blood cultures.

Authors:  P L Welby-Sellenriek; D S Keller; R J Ferrett; G A Storch
Journal:  J Clin Microbiol       Date:  1997-05       Impact factor: 5.948

8.  Effects of rapid detection of bloodstream infections on length of hospitalization and hospital charges.

Authors:  S E Beekmann; D J Diekema; K C Chapin; G V Doern
Journal:  J Clin Microbiol       Date:  2003-07       Impact factor: 5.948

9.  Pilot Testing of the "Turbidimeter", a Simple, Universal Reader Intended to Complement and Enhance Bacterial Growth Detection in Manual Blood Culture Systems in Low-Resource Settings.

Authors:  Barbara Barbé; Ellen Corsmit; Jasper Jans; Kamalpreet Kaur; Roel Baets; Jan Jacobs; Liselotte Hardy
Journal:  Diagnostics (Basel)       Date:  2022-03-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.