Literature DB >> 1748114

Evaluation of the new improved BHI-lysis blood culture medium for the BCB Roche system.

P Rohner1, H Burkardt, H Dreismann, R Auckenthaler.   

Abstract

The new BHI-lysis blood culture medium for the BCB system (BCB release, Hoffmann-La Roche), which lyses blood cells, was compared with the BHI-S broth of the same BCB system and the Signal system (Oxoid). A total of 2394 sets consisting of three bottles were each inoculated with 7 ml of blood at the bedside. In the laboratory agar-coated paddles were attached to the BHI-lysis and the BHI-S bottles, and the Signal device was mounted onto the Oxoid bottle. All systems were incubated at 35 degrees C for seven days. Of the 309 (13%) positive sets, 73 (3%) were contaminated and in 242 (10%) sets a total of 250 pathogenic microorganisms were isolated. These could be grown significantly more often from the BHI-lysis bottle (n = 213) than from either the BHI-S (n = 189) or Signal bottle (n = 176). No significant differences in the time needed to achieve a positive result was noted between the BHI-lysis and BHI-S bottles, but comparison of the BHI-lysis and Signal bottles revealed that overall pathogens were detected earlier significantly more often with the BHI-lysis bottle. In view of the good performance of blood culture broths containing lysing agents, their wider use is warranted in future.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1748114     DOI: 10.1007/bf01975812

Source DB:  PubMed          Journal:  Eur J Clin Microbiol Infect Dis        ISSN: 0934-9723            Impact factor:   3.267


  5 in total

1.  Comparative evaluation of the BCB Roche and Oxoid Signal blood culture systems.

Authors:  P Rohner; R Auckenthaler
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-02       Impact factor: 3.267

2.  Clinical comparison of the recoveries of bloodstream pathogens in Septi-Chek brain heart infusion broth with saponin, Septi-Chek tryptic soy broth, and the isolator lysis-centrifugation system.

Authors:  P R Murray; A W Spizzo; A C Niles
Journal:  J Clin Microbiol       Date:  1991-05       Impact factor: 5.948

3.  Comparison of the Roche Septi-Chek blood culture bottle with a brain heart infusion biphasic medium bottle and with a tryptic soy broth bottle.

Authors:  N K Henry; C M Grewell; C A McLimans; J A Washington
Journal:  J Clin Microbiol       Date:  1984-03       Impact factor: 5.948

4.  Comparison of lysis-centrifugation with a biphasic blood culture medium for the recovery of aerobic and facultatively anaerobic bacteria.

Authors:  N K Henry; C M Grewell; P E Van Grevenhof; D M Ilstrup; J A Washington
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

5.  The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I. Laboratory and epidemiologic observations.

Authors:  M P Weinstein; L B Reller; J R Murphy; K A Lichtenstein
Journal:  Rev Infect Dis       Date:  1983 Jan-Feb
  5 in total
  7 in total

1.  Advantage of combining resin with lytic BACTEC blood culture media.

Authors:  P Rohner; B Pepey; R Auckenthaler
Journal:  J Clin Microbiol       Date:  1997-10       Impact factor: 5.948

2.  The use of lysis-based procedures for blood cultures.

Authors:  J A Washington
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1991-08       Impact factor: 3.267

3.  Improved recovery of antibiotic-stressed microorganisms on inclusion of saponin in aerobic blood culture media.

Authors:  T S Elliott; C M Stevens; F Macrae; I T Hart; D E Healing; M Palmer; C R Catchpole
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1998-08       Impact factor: 3.267

4.  Comparative evaluation of BACTEC aerobic Plus/F and Septi-Chek Release blood culture media.

Authors:  P Rohner; B Pepey; R Auckenthaler
Journal:  J Clin Microbiol       Date:  1996-01       Impact factor: 5.948

5.  Evaluation of two commercial blood culture media for the detection of blood-borne pathogens.

Authors:  P Rohner; B Pepey; R Auckenthaler
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1994-01       Impact factor: 3.267

6.  Comparison of BacT/Alert with Signal blood culture system.

Authors:  P Rohner; B Pepey; R Auckenthaler
Journal:  J Clin Microbiol       Date:  1995-02       Impact factor: 5.948

7.  Controlled clinical comparison of two lysis-based blood culture systems, isolator and Septi-Chek Release, for detection of bloodstream infections.

Authors:  B A Kirkley; K A Easley; B A Basille; J A Washington
Journal:  J Clin Microbiol       Date:  1993-08       Impact factor: 5.948

  7 in total