The role of electronic portal imaging in tangential breast irradiation: a prospective study.

A Lirette1, J Pouliot, M Aubin, M Larochelle.   

Abstract

Side effects due to irradiation of normal tissues and local failure can be associated with deviations in the patient positioning in radiation therapy. In particular, tangential breast irradiation may include normal lung tissue or even a small portion of the heart in the field. A prospective study was performed to assess the precision and the reproducibility of the tangential breast irradiation technique with the help of on-line electronic portal imaging devices (EPID). The influence of respiration on the treatment set-up was evaluated. Also, a comparison was made with simulation films to study the degree of concordance with the intended treatment. Twenty patients with early breast cancer receiving post-operative radiotherapy were entered in the study. Geometrical parameters were measured from daily on-line portal images taken for approximately 17 fractions of each tangential fields. Multiple images were also acquired (six per field) for six fractions for all patients, yielding a total of 2120 images including the simulator films. Random and systematic errors were obtained. Variations of the parameters between various fractions and within the same fraction were about 3 mm (1 SD) or less. Variation between simulation and treatment set-up was 4.3 mm or less. Large maximum deviations, reaching 22.9 mm, were observed in rare cases. This confirms the need to implement daily verification procedures and to correct deviations in the treatment set-up. The study has shown that EPID can help reaching a high accuracy in patient treatment.

Entities:  

Mesh:

Year:  1995        PMID: 8746594     DOI: 10.1016/0167-8140(95)01653-8

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  11 in total

1.  Assessment of setup accuracy in patients receiving postmastectomy radiotherapy using electronic portal imaging.

Authors:  Funda Gul Koseoglu; Nina Tuncel; Adem Unal Kizildag; Melahat Garipagaoglu; Mustafa Adli; Cagatay Andic
Journal:  Radiat Med       Date:  2007-02-27

2.  Correction of systematic set-up error in breast and head and neck irradiation through a no-action level (NAL) protocol.

Authors:  Eva M Lozano; Luis A Pérez; Javier Torres; Carmen Carrascosa; Miguel Sanz; Fermín Mendicote; Antonio Gil
Journal:  Clin Transl Oncol       Date:  2011-01       Impact factor: 3.405

3.  Dosimetric and isocentric variations due to patient setup errors in CT-based treatment planning for breast cancer by electronic portal imaging.

Authors:  Hari Mukundan; Deboleena Mukherjee; Kirti Tyagi; Sachin Taneja; Subhash Ranjan; Samaresh Sahu
Journal:  Med J Armed Forces India       Date:  2018-10-15

4.  Setup Error and Effectiveness of Weekly Image-Guided Radiation Therapy of TomoDirect for Early Breast Cancer.

Authors:  Mi Joo Chung; Guk Jin Lee; Young Jin Suh; Hyo Chun Lee; Sea-Won Lee; Songmi Jeong; Jeong Won Lee; Sung Hwan Kim; Dae Gyu Kang; Jong Hoon Lee
Journal:  Cancer Res Treat       Date:  2015-02-13       Impact factor: 4.679

5.  Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy.

Authors:  Vikneswary Batumalai; Penny Phan; Callie Choong; Lois Holloway; Geoff P Delaney
Journal:  J Med Radiat Sci       Date:  2016-05-31

6.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

7.  Quantifying intra- and inter-fractional motion in breast radiotherapy.

Authors:  Scott Jones; Rhys Fitzgerald; Rebecca Owen; Jonathan Ramsay
Journal:  J Med Radiat Sci       Date:  2014-07-13

8.  Dosimetric Effects of the Interfraction Variations during Whole Breast Radiotherapy: A Prospective Study.

Authors:  Julian Jacob; Steve Heymann; Isabelle Borget; Isabelle Dumas; Elyes Riahi; Pierre Maroun; Patrick Ezra; Elena Roberti; Sofia Rivera; Eric Deutsch; Céline Bourgier
Journal:  Front Oncol       Date:  2015-09-16       Impact factor: 6.244

9.  Imaging dose in breast radiotherapy: does breast size affect the dose to the organs at risk and the risk of secondary cancer to the contralateral breast?

Authors:  Vikneswary Batumalai; Alexandra Quinn; Michael Jameson; Geoff Delaney; Lois Holloway
Journal:  J Med Radiat Sci       Date:  2015-01-07

10.  Surface imaging-based analysis of intrafraction motion for breast radiotherapy patients.

Authors:  David B Wiant; Stacy Wentworth; Jacqueline M Maurer; Caroline L Vanderstraeten; Jonathon A Terrell; Benjamin J Sintay
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.