Literature DB >> 17541512

Assessment of setup accuracy in patients receiving postmastectomy radiotherapy using electronic portal imaging.

Funda Gul Koseoglu1, Nina Tuncel, Adem Unal Kizildag, Melahat Garipagaoglu, Mustafa Adli, Cagatay Andic.   

Abstract

PURPOSE: The aim of this study was to investigate the setup accuracy for patients undergoing postmastectomy radiotherapy using electronic portal imaging.
MATERIALS AND METHODS: Ten patients undergoing radiotherapy via tangent (TG), supraclavicular-axillary (SA), and internal mammary (IM) fields were included. To explore the setup accuracy, distances between chosen landmarks were taken as reference parameters (RPs). The difference between measured RPs on simulation films and electronic portal images (EPIs) was calculated as the setup error.
RESULTS: A total of 30 simulation films and 120 EPIs were evaluated. In the SA field, calculated RPs were lung length (LL), clavicle-field center perpendicular distance, and clavicle-field center transverse distance. The mean of the standard deviations (SDs) of the random errors (sigma) for these parameters were 4.7, 7.3, and 7.6; and the SDs of the systematic errors (Sigma) were 6.8, 4.4, and 13.5, respectively. In the TG fields, the calculated RPs were the central lung distance (CLD), maximum lung distance (MLD), and central soft-tissue distance (CSTD). In the medial TG field, the sigma values for these parameters were 3.4, 3.6, and 4.1, respectively; and the sigma values were 6.6, 2.6, and 3.4, respectively. In the lateral TG field, Sigma values for the calculated RPs were 2.4, 3.2, and 3.3l, respectively; and the Sigma values were 5.6, 3.6, and 4.8, respectively.
CONCLUSION: CLD, MLD, and CSTD in TG fields and LL in SA fields are easily identifiable and are helpful for detecting setup errors using EPIs in patients undergoing postmastectomy radiotherapy.

Entities:  

Mesh:

Year:  2007        PMID: 17541512     DOI: 10.1007/s11604-006-0102-6

Source DB:  PubMed          Journal:  Radiat Med        ISSN: 0288-2043


  26 in total

1.  An assessment of the number of CT slices necessary to plan breast radiotherapy.

Authors:  D Vincent; W Beckham; G Delaney
Journal:  Radiother Oncol       Date:  1999-08       Impact factor: 6.280

2.  An improved breast irradiation technique using three-dimensional geometrical information and intensity modulation.

Authors:  B van Asselen; C P Raaijmakers; P Hofman; J J Lagendijk
Journal:  Radiother Oncol       Date:  2001-03       Impact factor: 6.280

3.  Radiation pneumonitis in breast cancer patients treated with conservative surgery and radiation therapy.

Authors:  T I Lingos; A Recht; F Vicini; A Abner; B Silver; J R Harris
Journal:  Int J Radiat Oncol Biol Phys       Date:  1991-07       Impact factor: 7.038

4.  Dosimetric improvements following 3D planning of tangential breast irradiation.

Authors:  A Aref; D Thornton; E Youssef; T He; S Tekyi-Mensah; L Denton; G Ezzell
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-12-01       Impact factor: 7.038

5.  Postoperative radiotherapy in high-risk premenopausal women with breast cancer who receive adjuvant chemotherapy. Danish Breast Cancer Cooperative Group 82b Trial.

Authors:  M Overgaard; P S Hansen; J Overgaard; C Rose; M Andersson; F Bach; M Kjaer; C C Gadeberg; H T Mouridsen; M B Jensen; K Zedeler
Journal:  N Engl J Med       Date:  1997-10-02       Impact factor: 91.245

6.  Reduction of cardiac and lung complication probabilities after breast irradiation using conformal radiotherapy with or without intensity modulation.

Authors:  Coen W Hurkmans; B C John Cho; Eugene Damen; Lambert Zijp; Ben J Mijnheer
Journal:  Radiother Oncol       Date:  2002-02       Impact factor: 6.280

7.  Neoadjuvant chemotherapy in breast cancer: significantly enhanced response with docetaxel.

Authors:  Ian C Smith; Steven D Heys; Andrew W Hutcheon; Iain D Miller; Simon Payne; Fiona J Gilbert; Antoinne K Ah-See; Oleg Eremin; Leslie G Walker; Tarun K Sarkar; S Peter Eggleton; Keith N Ogston
Journal:  J Clin Oncol       Date:  2002-03-15       Impact factor: 44.544

8.  Adjuvant treatment of node-positive breast cancer with cyclophosphamide, doxorubicin, fluorouracil, and vincristine versus cyclophosphamide, methotrexate, and fluorouracil: final report after a 16-year median follow-up duration.

Authors:  J L Misset; M di Palma; M Delgado; R Plagne; P Chollet; P Fumoleau; B Le Mevel; D Belpomme; J Guerrin; P Fargeot; R Metz; M Ithzaki; C Hill; G Mathé
Journal:  J Clin Oncol       Date:  1996-04       Impact factor: 44.544

Review 9.  Accuracy in tangential breast treatment set-up: a portal imaging study.

Authors:  G van Tienhoven; J H Lanson; D Crabeels; S Heukelom; B J Mijnheer
Journal:  Radiother Oncol       Date:  1991-12       Impact factor: 6.280

10.  Quality assurance using portal imaging: the accuracy of patient positioning in irradiation of breast cancer.

Authors:  C L Creutzberg; V G Althof; H Huizenga; A G Visser; P C Levendag
Journal:  Int J Radiat Oncol Biol Phys       Date:  1993-02-15       Impact factor: 7.038

View more
  3 in total

1.  Analysis of local setup errors of sub-regions in cone-beam CT-guided post-mastectomy radiation therapy.

Authors:  Jidan Zhou; Shuai Li; Chengwei Ye; Konglong Shen; An Li; Gang Chen; Xiaoyu Li; Sen Bai; Weifeng Wang; Renming Zhong
Journal:  J Radiat Res       Date:  2020-05-22       Impact factor: 2.724

2.  Surface imaging-based analysis of intrafraction motion for breast radiotherapy patients.

Authors:  David B Wiant; Stacy Wentworth; Jacqueline M Maurer; Caroline L Vanderstraeten; Jonathon A Terrell; Benjamin J Sintay
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

3.  Real-time intra-fraction motion management in breast cancer radiotherapy: analysis of 2028 treatment sessions.

Authors:  D Reitz; G Carl; S Schönecker; M Pazos; P Freislederer; M Niyazi; U Ganswindt; F Alongi; M Reiner; C Belka; S Corradini
Journal:  Radiat Oncol       Date:  2018-07-16       Impact factor: 3.481

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.